Behaviour and design of high-strength steel beam-to-column joints  

Li, Dongxu (School of Civil Engineering, The University of Sydney)
Uy, Brian (School of Civil Engineering, The University of Sydney)
Wang, Jia (School of Civil Engineering, The University of Sydney)
Publication Information
Steel and Composite Structures / v.31, no.3, 2019 , pp. 303-317 More about this Journal
Abstract
This paper presents a finite element model for predicting the behaviour of high-strength steel bolted beam-to-column joints under monotonic loading. The developed numerical model considers the effects of material nonlinearities and geometric nonlinearities. The accuracy of the developed model is examined by comparing the predicted results with independent experimental results. It is demonstrated that the proposed model accurately predicts the ultimate flexural resistances and moment-rotation curves for high-strength steel bolted beam-to-column joints. Mechanical performance of three joint configurations with various design details is examined. A parametric study is carried out to investigate the effects of key design parameters on the behaviour of bolted beam-to-column joints with double-extended endplates. The plastic flexural capacities of the beam-to-column joints from the experimental programme and numerical analysis are compared with the current codes of practice. It is found that the initial stiffness and plastic flexural resistance of the high-strength steel beam-to-column joints are overestimated. Proper modifications need to be conducted to ensure the current analytical method can be safely used for the bolted beam-to-column joints with high-performance materials.
Keywords
high-strength steel; beam-to-column joint; numerical analysis; design codes;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Zanon, P. and Zandonini, R. (1988), "Experimental analysis of endplate connections", Proceedings of the State of the Art Workshop on Connections and the Behaviour of Strength and Design of Steel Structures, Cachan, France, pp. 41-51.
2 Shi, G., Shi, Y., Wang, Y. and Bradford, M.A. (2008), "Numerical simulation of steel pretensioned bolted end-plate connections of different types and details", Eng. Struct., 30, 2677-2686.   DOI
3 Shi, G., Ban, H. and Bijlaard, F.S.K. (2012), "Tests and numerical study of ultra-high strength steel columns with end restraints", J. Constr. Steel Res., 70, 236-247.   DOI
4 Skalomenos, K.A., Hayashi, K., Nishi, R., Inamasu, H. and Nakashima, M. (2016), "Experimental behaviour of concretefilled steel tube columns using ultrahigh-strength steel", J. Struct. Eng., 142(9), 04016057.   DOI
5 Tahir, M.M., Mohammadhosseini, H., Ngian, S.P. and Effendi, M.K. (2018), "I-beam to square hollow column blind bolted moment connection: Experimental and numerical study", J. Constr. Steel Res., 148, 383-398.   DOI
6 Tartaglia, R., D'Aniello, M. and Landolfo, R. (2018), "The influence of rib stiffeners on the response of extended end-plate joints", J. Constr. Steel Res., 148, 669-690.   DOI
7 Thai, H.T., Uy, B., Khan, M., Tao, Z. and Mashiri, F. (2014), "Numerical modelling of concrete-filled steel box columns incorporating high strength materials", J. Constr. Steel Res., 102, 256-265.   DOI
8 Thai, H.T., Vo, T.P., Nguyen, T.K. and Pham, C.H. (2017), "Explicit simulation of bolted endplate composite beam-to-CFST column connections", Thin-Wall. Struct., 119, 749-759.   DOI
9 Uy, B. (2001), "Strength of short concrete-filled high strength steel box columns", J. Constr. Steel Res., 57(2), 113-134.   DOI
10 Uy, B., Patel, V., Li, D. and Aslani, F. (2017), "Behaviour and design of connections for demountable steel and composite structures", Structures, 9, 1-12.   DOI
11 Vasdravellis, G. and Uy, B. (2014), "Shear strength and momentshear interaction in steel-concrete composite beams", J. Struct. Eng., 140(11), 04014084.   DOI
12 Vasdravellis, G., Valente, M. and Castiglioni, C.A. (2009), "Behaviour of exterior partial-strength composite beam-tocolumn connections: Experimental study and numerical simulations", J. Constr. Steel Res., 65(1), 23-35.   DOI
13 Wang, J., Uy, B. and Li, D. (2018), "Analysis of demountable steel and composite frames with semi-rigid bolted joints", Steel Compos. Struct., Int. J., 28(3), 363-380.
14 Weynand, K. (1997), "Sicherheits-und Wirtschaftlichkeitsuntersuchungen zur Anwendung nachgiebiger Anschlusse im Stahlbau", Heft, 35. Aachen: Shaker Verlag.
15 Wilkinson, S., Hurdman, G. and Crowther, A. (2006), "A moment resisting connections for earthquake resistant structures", J. Constr. Steel Res., 62, 295-302.   DOI
16 Xiong, M.X., Xiong, D.X. and Liew, J.Y.R. (2017), "Axial performance of short concrete filled steel tubes with high- and ultra-high-strength materials", Eng. Struct., 136, 494-510.   DOI
17 Xu, F., Chen, J. and Chan, T.M. (2017), "Numerical analysis and punching shear fracture based design of longitudinal plate to concrete-filled CHS connections", Constr. Build. Mater., 156(15), 91-106.   DOI
18 AS4100-1998 (1998), Standards Australia, Steel structures.
19 AS/NZS 5100.6-2017 (2017), Standards Australia, Bridge Design, Part 6: Steel and Composite Construction.
20 AS/NZS 2327-2017 (2017), Standards Australia, Composite structures-composite steel-concrete construction in buildings.
21 Augusto, H., Silva, L.S.D., Rebelo, C. and Castro, J.M. (2016), "Characterization of web panel components in double-extended bolted end-plate steel joints", J. Constr. Steel Res., 116, 271-293.   DOI
22 Ban, H.Y., Shi, G., Shi, Y. and Bradford, M.A. (2013), "Experimental investigation of the overall buckling behaviour of 960 MPa high strength steel columns", J. Constr. Steel Res., 88, 256-266.   DOI
23 Chen, J., Young, B. and Uy, B. (2006), "Behaviour of high strength structural steel at elevated temperatures", J. Constr. Steel Res., 132(12), 1948-1954.
24 Coelho, A.M.G. and Bijlaard, F.S.K. (2007), "Experimental behaviour of high strength steel end-plate connections", J. Constr. Steel Res., 63, 1228-1240.   DOI
25 Coelho, A.M.G., Simoes, D.S.L. and Bijlaard, F.S.K. (2006), "Ductility analysis of bolted extended endplate beam-to-column connections in the framework of the component method", Steel Compos. Struct., Int. J., 6(1), 33-53.   DOI
26 Du, Y., Chen, Z., Liew, J.Y.R. and Xiong, M.X. (2017), "Rectangular concrete-filled steel tubular beam-columns using high-strength steel: Experiments and design", Journal of constructional steel research, 131: 1-18.   DOI
27 Eurocode 3 (2005), Design of Steel Structures-Part 1-8: Design of joints, BS EN 1993-1-12, London, UK.
28 Eurocode 3 (2007), Design of Steel Structures-Part 1-12: Additional rules for the extension of EN1993 up to steel grades S700, BS EN 1993-1-12, London, UK.
29 Francavilla, A.B., Latour, M., Piluso, V. and Rizzano, G. (2018), "Design of full-strength full-ductility extended end-plate beamto-column joints", J. Constr. Steel Res., 148, 77-96.   DOI
30 Ge, H., Jia, L.J., Kang, L. and Suzuki, T. (2014), "Experimental study on seismic performance of partial penetration welded steel beam-to-column joints with different fillet radii", Steel Compos. Struct., Int. J., 17(6), 851-865.   DOI
31 Gholami, M., Deylami, A. and Tehranizadeh, M. (2013), "Seismic performance of flange plate connections between steel beams and box columns", J. Constr. Steel Res., 84, 36-48.   DOI
32 ABAQUS 6.16, (2016), Computer software, Dassault systems, Waltham, MA, USA.
33 Abidelah, A., Bouchair, A. and Kerdal, D.E. (2012), "Experimental and analytical behaviour of bolted end-plate connections with or without stiffeners", J. Constr. Steel Res., 76, 13-27.   DOI
34 Gogou, E. (2012), "Use of high strength steel grades for economical bridge design", Master Thesisl Delft University of Technology, Netherlands.
35 Goswami, R. and Murty, C.V.R. (2010), "Externally reinforced welded I-beam-to-box-column seismic connection", J. Constr. Steel Res., 136(1), 23-30.
36 Gunther, H-P. (2005), "Use and Application of High-performance Steels for Steel Structures", International Association for Bridge and Structural Engineering (IABSE); Structural Engineering Documents, Vol. 8.
37 Johnson, G.R. and Cook, W.H. (1985), "Fracture characteristics of three metals subjected to various strains, strain rates, temperatures and pressures", Eng. Fract. Mech., 21(1), 31-48.   DOI
38 Kim, Y.J. and Oh, S.H. (2007), "Effects of moment transfer efficiency of a beam web on deformation capacity at box column-to-H beam connections", J. Constr. Steel Res., 63, 24-36.   DOI
39 Li, D., Uy, B., Patel, V. and Aslani, F. (2016a), "Behaviour and design of demountable steel column-column connections", Steel Compos. Struct., Int. J., 22(2), 429-448.   DOI
40 Li, D., Uy, B., Aslani, F. and Patel, V. (2016b), "Analysis and design of demountable steel column-baseplate connections", Steel Compos. Struct., Int. J., 22(4), 753-775.   DOI
41 Li, T.J., Li, G.Q., Chan, S.L. and Wang, Y.B. (2016c), "Behaviour of Q690 high-strength steel columns: Part 1: Experimental investigation", J. Constr. Steel Res., 123, 18-30.   DOI
42 Li, D., Uy, B., Aslani, F. and Patel, V. (2018), "Behaviour and design of demountable CFST column-column connections under tension", J. Constr. Steel Res., 138, 761-773.   DOI
43 Liu, X.C., Yang, Z.W., Wang, H.X., Zhang, A.L., Hu, S.H., Chai, S.T. and Wu, L. (2017), "Seismic performance of H-section beam to HSS column connection in prefabricated structures", J. Constr. Steel Res., 138, 1-16.   DOI
44 Mirghaderi, S.R., Torabian, S. and Keshavarzi, F. (2010), "I-beam to box-column connection by a vertical plate passing through the column", Eng. Struct., 32, 2034-2048.   DOI
45 Morrison, M., Quayyum, S. and Hassan, T. (2017), "Performance enhancement of eight bolt extended end-plate moment connections under simulated seismic loading", Eng. Struct., 151, 444-458.   DOI
46 Oh, S.H. and Park, H.Y. (2016), "A study to enhance the deformation capacity of beam-to-column connections using high strength steel having high yield ratio", Int. J. Steel Struct., 16(1), 73-89.   DOI
47 Portoles, J.M., Serra, E. and Romero, M.L. (2013), "Influence of ultra-high strength infill in slender concrete-filled steel tubular columns", J. Constr. Steel Res., 86, 107-114.   DOI
48 Qiang, X., Bijlaard, F.S.K., Kolstein, H. and Jiang, X. (2014), "Behaviour of beam-to-column high strength steel endplate connections under fire conditions-Part 1: Experimental study", Eng. Struct., 64, 23-38.   DOI
49 Qiang, X., Jiang, X., Bijlaard, F.S.K., Kolstein, H. and Luo, Y. (2015), "Post-fire behaviour of high strength steel endplate connections-Part 1: Experimental study", J. Constr. Steel Res., 108, 82-93.   DOI
50 Sabbagh, A.B., Chan, T.M. and Mottram, J.T. (2013), "Detailing of I-beam-to-CHS column joints with external diaphragm plates for seismic actions", J. Constr. Steel Res., 88, 21-33.   DOI