• Title/Summary/Keyword: Beam angle

검색결과 1,349건 처리시간 0.038초

Reflection of a gaussian beam from a planar dielectric interface

  • Lee, Yeon H.
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.200-206
    • /
    • 1996
  • When a Gaussian beam is incident to a planar dielectric interface at an angle other than Brewster angle or the critical angle of total reflection, we derive the six nonspecular effects of rotation, lateral shift, focal shift, Rayleigh length change, magnitude and phase changes in the complex amplitude of the reflected beam simultaneously by taking account of the boundary condition. In the derivation we assume a Gaussian beam of fundamental mode to emerge from the interface and then match at the interface the constant, linear, and quadratic variations of the amplitude and phase of the reflected beam with those of the incident beam multiplied by the reflection coefficient. Our calculation shows that the six nonspecular effects can result from a linear variation of the natural logarithm of the reflection coefficient at the interface.

  • PDF

Predicting shear strength of RC exterior beam-column joints by modified rotating-angle softened-truss model

  • Wong, Simon H.F.;Kuang, J.S.
    • Computers and Concrete
    • /
    • 제8권1호
    • /
    • pp.59-70
    • /
    • 2011
  • A theoretical model known as the modified rotating-angle softened-truss model (MRA-STM), which is a modification of Rotating-Angle Softened-Truss Model and Modified Compression Field Theory, is presented for the analysis of reinforced concrete membranes in shear. As an application, shear strength and behaviour of reinforced concrete exterior beam-column joints are analysed using the MRA-STM combining with the deep beam analogy. The joints are considered as RC panels and subjected to vertical and horizontal shear stresses from adjacent columns and beams. The strut and truss actions in a beam-column joint are represented by the effective transverse compression stresses and a softened concrete truss in the proposed model. The theoretical predictions of shear strength of reinforced concrete exterior beam-column joints from the proposed model show good agreement with the experimental results.

Alignment Effect of a Nematic Liquid Crystal on Deposited SiOx Thin-Film Surface with e-beam Evaporation

  • Oh, Yong-Cheul;Lee, Dong-Gyu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.305-308
    • /
    • 2006
  • We have studied liquid crystal (LC) aligning capabilities for homeotropic alignment and the control of tilt angles on the $SiO_{x}$ thin film by electron beam evaporation method. A high tilt angle of about $86.5^{\circ}$ was obtained, and also the suitable tilt angle of the NLC on the $SiO_{x}$ thin film at $20{\sim}50\;nm$ thickness with e-beam evaporation can be achieved. The uniform LC alignment on the $SiO_{x}$ thin film surfaces with electron beam evaporation can be achieved. It is considerated that the LC alignment on the $SiO_{x}$ thin film by electron beam evaporation is attributed to elastic interaction between LC molecules and micro-grooves at the $SiO_{x}$ thin film surface created by evaporation.

Statistical Modeling of Pretilt Angle Control using Ion-beam Alignment on Nitrogen Doped Diamond-like Carbon Thin Film

  • Kang, Hee-Jin;Lee, Jung-Hwan;Han, Jung-Min;Yun, Il-Gu;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.297-300
    • /
    • 2006
  • The response surface modeling of the pretilt angle control using ion-beam (IB) alignment on nitrogen doped diamond-like carbon (NDLC) thin film layer is investigated. This modeling is used to analyze the variation of the pretilt angle under various process conditions. IB exposure angle and IB exposure time are considered as input factors. The analysis of variance technique is settled to analyze the statistical significance, and effect plots are also investigated to examine the relationships between the process parameters and the response. The model can allow us to reliably predict the pretilt angle with respect to the varying process conditions.

초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석 (Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer)

  • 남영현
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

Basic Properties of Cell Fabricated by Ion-beam Treatment for In-plane Switching LCD

  • Seo, Joo-Hong;Lee, Sung-Pil;Yoon, Tae-Hoon;Kim, Jae-Chang
    • Journal of Information Display
    • /
    • 제7권1호
    • /
    • pp.12-18
    • /
    • 2006
  • We investigated the horizontal alignment properties such as surface morphology, pretilt angle, and polar and azimuthal anchoring energy of organic alignment material-coated surface treated by ion beam. In this investigation the energy and incident angle of ion beam were changed. We also fabricated an in-plane switching (IPS) cell by ion beam alignment. The results showed similar voltage-transmittance characteristics to those of a rubbed cell and better dark state.

충전형 합성보와 포밍앵글 기둥 접합부의 내진성능에 대한 실험적 평가 (Experimental Evaluation on Seismic Performance of Filled Composite Beam - to - Forming Angle Composite Column Connections)

  • 김형섭;이경구;구지모
    • 한국지진공학회논문집
    • /
    • 제20권1호
    • /
    • pp.71-77
    • /
    • 2016
  • In this study, the seismic performance of connections between filled composite beam (CG beams) and forming angle composite (FAC) column was experimentally evaluated. First, the bending tests were conducted on two CG beams and the axial tests were conducted on two FAC columns. Then, based on these preliminary test results, the cyclic loading test were performed on two interior connections between CG beam and FAC column. The main difference of two specimens is the plate shape of the CG beam. The test results showed that both specimens achieved the maximum story drift capacity over 0.04 radian which is required for special moment frame.

빔틸트 특성을 갖는 하이패스 안테나의 개발 (The development of a Hipass antenna with the beam-tilted properties)

  • 한윤구;정수진;임계재
    • 한국정보전자통신기술학회논문지
    • /
    • 제1권2호
    • /
    • pp.57-63
    • /
    • 2008
  • In this paper, we develop the Hipass antenna that is used in electronic tall-gate charging (ETC) system in Korea expressway. This antenna has circular polarized characteristics, and especially has 45 degree tilted beam properties. These properties are very effective in ETC communication between the vehicle antenna and the tall-gate antenna. To achieve these properties on a small microstrip type antenna structure, we propose a annular ring microstrip antenna with stubs. When the length and angle of stubs are changed, the direction of the circular polarized beam is generally tilted by $45^{\circ}$ in elevation angle. Especially, by using the stubs in inner area or outer area of ring antenna, it is found that the beam direction of in azimuth angle can be rotated.

  • PDF

$SiO_2$ 식각을 위한 판형 Low Angle forward Reflected Neutral Beam 식각장치에 관한 연구

  • 정승재;이도행;염근영
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 춘계학술발표회 초록집
    • /
    • pp.56-56
    • /
    • 2003
  • 플라즈마 식각에서 물리적 손상과 전기적 손상은 차세대 Nanoscale 소자와 Deep - Submicron 반도체공정에서 해결되어야 할 가장 큰 문제 중 하나이다. 이 중 전기적인 손상을 줄이기 위한 몇 가지 무손상 공정이 제시되고 있으며, 그러한 기술 중의 하나가 이온빔의 Low Angle Forward Reflection을 이용한 식각방법이다. Low Angle Forward Reflection방법은 이온소오스로부터 발생시킨 이온을 Low Angle 에서 Reflection-시켜 이온빔을 중성화되도록 하는 방법으로, 이전 연구를 통해 Reflection시 입사각이 5도일 경우 대부분의 이온들이 중성화되는 결과를 얻었다. 또한, 실험에 사용된 $SF_6,{\;}NF_3,{\;}CF_4$와 같은 모든 가스종에서 유사한 값의 중성화 정도를 관찰할 수 있었으며, 이러한 가스를 이용하여 $Si0_2$ 식각시 Vertical한 Profile 결과를 얻었다. 본 연구에서는 기존 Grid 장치에서 이온소오스 부분에 Low Angle Forward Reflected Neutral Beam을 위한 판형 Reflector를 부착하였으며, 이에 따라 중성빔의 Flux가 크게 향상되며 Beam의 직진성을 향상시킬 수 있었다. 또한, F계열 가스를 이용한 실험을 통해 $Si0_2$ 식각율과 식각특성 면에서 향상된 실험결과를 얻을 수 있었다.

  • PDF