• Title/Summary/Keyword: Battery-less

Search Result 241, Processing Time 0.031 seconds

A Case Study on Electronic Recognition Sensor for Underground Facility Management System (지중 매설물 이력 관리 시스템 개발을 위한 전자인식기의 현장 적용성 검증 연구)

  • Jung, YooSeok;Kim, Soullam;Kim, Byungkon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.777-785
    • /
    • 2021
  • Many utility lines are buried underground to provide various functions of the city. Because historical records are not managed systematically, damage has occurred during excavation. In addition, the demand for an underground facility management system is increasing as the aerial underground project is progressing. By attaching an electronic recognition sensor to an underground facility, such as pipelines, the management history and site conditions can be carefully managed. Therefore, in this study, electronic recognition sensors, such as BLE Beacon, UHF RFID, geomagnetic sensor, and commercial marker, were tested to analyze the strengths, weaknesses, and field applicability through a pilot project. According to the limited research results collected through two pilot projects, the installation depth is most important to demonstrate the performance of the electronic reader. In addition, because it should be used in urban areas, the influence of environmental interference should be minimized, and there should be no performance degradation over time. In the case of the geomagnetic recognizer, the effect of environmental interference was large, and performance degradation occurred over time using the BLE Beacon. In the field situation, where the installation depth can be controlled to less than 40cm, the utility of the battery-free UHF RFID was the best.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

The Comparative Study on Mental Representation between Foster-care and Typical Children (위탁 아동과 일반 아동의 정신적 표상 비교)

  • Min Jung Go;Kyung Sook Lee;Yun Mi Kim;In Ae Choi
    • Korean Journal of Culture and Social Issue
    • /
    • v.19 no.3
    • /
    • pp.507-528
    • /
    • 2013
  • The study examined the mental representation of children in foster care through the MacArthur Story Stem Battery (MSSB) and reviewed difference between children in foster care and typical children in terms of mental representation. Subjects of the study included a total of 50 children: 25 children (11 boys and 14 girls), aged from 5 to 8, in foster care in Gyeonggi Province, and 25 typical children (11 boys and 14 girls), aged from 5 to 8, who lived in Seoul and Gyeonggi Province. The research findings are summarized as follows: First, in terms of mental representation, children in foster care showed less subjects of empathic relations and more subjects of disorganized aggression than typical children. Second, children in foster care showed lower coherence mental representation than typical children. Finally, children in foster care were more likely to fail in emotional regulation than typical children in mental representation.

  • PDF

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF

Electrochemical Properties of Pyrolytic Carbon and Boron-doped Carbon for Anode Materials In Li-ion Secondary Batteries (리튬 이온 이차전지 부극용 열분해 탄소 및 붕소첨가 탄소의 전기화학적 특성)

  • Kwon, Ik-Hyun;Song, Myoung-Youp;Bang, Eui-Yong;Han, Young-Soo;Kim, Ki-Tae;Lee, Jai-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.1
    • /
    • pp.30-38
    • /
    • 2002
  • Disordered carbon and boron-substituted disordered carbons $C_{l-x}B_x(x=0.05,\;0.10,\;0.20)$ were synthesized by Pyrolysis of LPG(liquid Propane gas)and $BCl_3$. Their electrochemical properties as anode materials for Li-ion secondary batteries were then investigated. When PVDF is added to the sample in a weight ratio 5 : 95, the disordered carbon with x=0.00 had the first discharge capacity 374 mAh/g. Its cycling performance was relatively good from the second cycle and it had the discharge capacity 258 mAh/g at the 10th cycle. When PVDF is added to the sample in a weight ratio 5 : 95, the sample with x=0.05 among the samples $C_{l-x}B_x(x=0.05,\;0.10,\;0.20)$ exhibited the largest first discharge capacity 860 mAh/g and discharge capacity 181 mAh/g at the 10th cycle. All the samples had similar cycling performances from the second cycle. The sample $C_{0.90}B_{0.10}$ showed the best electrochemical properties as a anode materials fur Li-ion secondary battery from the view points of the first discharge capacity(853 mAh/g when $10w1.\%$ PVDF is used), cycling performance, discharge capacity(400mAh/g at the 10th cycle when $10wt.\%$ PVDF is used). All the samples showed generally larger charge and discharge capacities when $10wt.\%$ PVDF ratter than $5wt.\%$ PVDF is used. The plateau region in the range of voltage lower than 1.25V becomes larger probably since the structure becomes less disordered by the addition of boron. When boron is added, the charge and discharge capacities decreased suddenly at the second cycle. This may be become only a part of Li are reversibly deintercalated and intercalated and a part of Li which are strongly combined with B are not deintercalated. The increases in charge and discharge capacities are considered to be resulted from the increase in the potential of Li in the boron-added carbons, caused by the strengthening of the chemical bond between the intercalated Li and the boron-carbon host since the boron acts as electron acceptor.

Factors Related to Poor School Performance of Elementary School Children (국민학교아동의 학습부진에 관련된 요인)

  • Park, Jung-Han;Kim, Gui-Yeon;Her, Kyu-Sook;Lee, Ju-Young;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.4 s.44
    • /
    • pp.628-649
    • /
    • 1993
  • This study was conducted to investigate the factors related to the poor school performance of the elementary school children. Two schools in Taegu, one in the affluent area and the other in the poor area, were selected and a total of 175 children whose school performance was within low 10 percentile (poor performers) and 97 children whose school performance were within high 5 percentile (good performers) in each class of 2nd, 4th and 6th grades were tested for the physical health, behavioral problem and family background. Each child had gone through a battery of tests including visual and hearing acuity, anthropometry (body weight, height, head circumference), intelligence (Kodae Stanford-Binet test), test anxiety (TAI-K), neurologic examination by a developmental pediatrician and heavy metal content (Pb, Cd, Zn) in hair by atomic absorption spectrophotometry. A questionnaire was administered to the mothers for prenatal and prenatal courses of the child, family environment, child's developmental history, and child's behavioral and learning problems. Another questionnaire was administered to the teachers of the children for the child's family background, arithmatic & language abilities and behavioral problem. The poor school performance had a significant correlation with male gender, high birth order, broken home, low educational and occupational levels of parents, visual problem, high test anxiety score, attention deficit hyperactivity disorder (ADHD), poor physical growth (weight, height, head circumference) and low I.Q. score. The factors that had a significant correlation with the poor school performance in multiple logistic regression analysis were child's birth order (odds ratio=2.06), male gender(odds ratio=5.91), broken home(odds ratio=9.29), test anxiety score(odds ratio=1.07), ADHD (odds ratio=9.67), I.Q. score (odds ratio=0.85) and height less than Korean standard mean-1S.D.(odds ratio=11.12). The heavy metal contents in hair did not show any significant correlation with poor school performance. However the lead and cadmium contents were high in males than in females. The lead content was negatively correlated with child's grade(P<0.05) and zinc was positively correlated with grade (P<0.05). among the factors that showed a significant correlation with the poor school performance, high birth order, short stature and ADHD may be modified by a good family planning, good feeding practice for infant and child, and early detection and treatment of ADHD. Also, teacher and parents should restrain themselves from inducing excessive test anxiety by forcing the child to study and over-expecting beyond the child's intellectual capability.

  • PDF

A Study of Performance Analysis on Effective Multiple Buffering and Packetizing Method of Multimedia Data for User-Demand Oriented RTSP Based Transmissions Between the PoC Box and a Terminal (PoC Box 단말의 RTSP 운용을 위한 사용자 요구 중심의 효율적인 다중 수신 버퍼링 기법 및 패킷화 방법에 대한 성능 분석에 관한 연구)

  • Bang, Ji-Woong;Kim, Dae-Won
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.1
    • /
    • pp.54-75
    • /
    • 2011
  • PoC(Push-to-talk Over Cellular) is an integrated technology of group voice calls, video calls and internet based multimedia services. If a PoC user can not participate in the PoC session for various reasons such as an emergency situation, lack of battery capacity, then the user can use the PoC Box which has a similar functionality to the MM Box in the MMS(Multimedia Messaging Service). The RTSP(Real-Time Streaming Protocol) method is recommended to be used when there is a transmission session between the PoC box and a terminal. Since the existing VOD service uses a wired network, the packet size of RTSP-based VOD service is huge, however, the PoC service has wireless communication environments which have general characteristics to be used in RTSP method. Packet loss in a wired communication environments is relatively less than that in wireless communication environment, therefore, a buffering latency occurs in PoC service due to a play-out delay which means an asynchronous play of audio & video contents. Those problems make a user to be difficult to find the information they want when the media contents are played-out. In this paper, the following techniques and methods were proposed and their performance and superiority were verified through testing: cross-over dual reception buffering technique, advance partition multi-reception buffering technique, and on-demand multi-reception buffering technique, which are designed for effective picking up of information in media content being transmitted in short amount of time using RTSP when a user searches for media, as well as for reduction in playback delay; and same-priority packetization transmission method and priority-based packetization transmission method, which are media data packetization methods for transmission. From the simulation of functional evaluation, we could find that the proposed multiple receiving buffering and packetizing methods are superior, with respect to the media retrieval inclination, to the existing single receiving buffering method by 6-9 points from the viewpoint of effectiveness and excellence. Among them, especially, on-demand multiple receiving buffering technology with same-priority packetization transmission method is able to manage the media search inclination promptly to the requests of users by showing superiority of 3-24 points above compared to other combination methods. In addition, users could find the information they want much quickly since large amount of informations are received in a focused media retrieval period within a short time.

Development of Korean Neurobehavioral Test Battery -Assessment of the Validity of Traditional and Computerized Neurobehavioral Tests- (한국형 신경행동검사 배터리의 개발 -면접과 컴퓨터 신경행동검사의 타당성 평가-)

  • Chung, Jong-Hak;Kim, Chang-Yoon;SaKong, Joon;Jeon, Man-Joong;Park, Hong-Chin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.692-707
    • /
    • 1998
  • Aim. A neurobehavioral test for workers exposed to organic solvents in the workplace can be affected by many factors : age, education, motivation, ethnicity, etc. To apply more suitable neurobehavioral test for Korean workers, we evaluated the validity of several items of computerized and traditional neurobehavioral tests. Methods. We have applied eleven tests : four items of computerized neurobehavioral test(Swedish Performance Evaluation System) including Addition, Symbol-Digit, Dig-it Span, and Finger tapping speed, and seven items of traditional neurobehavioral test consisting of Addition, Digit-Symbol, Digit Span, Benton visual retention test, Pursuit aiming, Pegboard, and Tapping. These tests were performed on 96 workers exposed to solvents, and 100 reference workers. The concurrent and construct validities were evaluated by group difference, correlation with age, educational level, hippuric acid level, neurotoxic symptom, current exposure level, multitrait-multimethod matrix, fator analysis, and discriminant analysis. Results. Statistically significant differences were observed between the workers exposed to solvents and referents in computerized Symbol-Digit, Finger tapping speed, traditional Digit-Symbol and Pegboard. The computerized Symbol-Digit, traditional Digit-Symbol, Addition, Benton visual retention test, and Pegboard were found to be related to the age. The performance of computerized Symbol-Digit, Addition, and traditional Digit-Symbol were found to be related to the educational level significantly. The computerized Symbol-Digit, Finger tapping speed, and traditional Digit-Symbol were found to be related to hippuric acid, and neurotoxic symptom. The discriminability of Finger tapping speed, and Pegboard was better than the other tests. In discriminant analysis, the model with two variables, the computerized Symbol-Digit and Pegboard, classified almost 70 percent of the workers correctly. Conclusions. These results suggest that the computerized Symbol-Digit, Finger tapping speed, and Pegboard are more satisfactory for our purpose, and the Addition, Tapping, Benton visual retention test, and Pursuit aiming are less valid than other items. These may allow the reasonable selection of core neurobehavioral tests for workers exposed to solvents in Korea.

  • PDF

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF