• Title/Summary/Keyword: Balancing Simulation

Search Result 467, Processing Time 0.025 seconds

Performance Analysis of a Novel Reduced Switch Cascaded Multilevel Inverter

  • Nagarajan, R.;Saravanan, M.
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.48-60
    • /
    • 2014
  • Multilevel inverters have been widely used for high-voltage and high-power applications. Their performance is greatly superior to that of conventional two-level inverters due to their reduced total harmonic distortion (THD), lower switch ratings, lower electromagnetic interference, and higher dc link voltages. However, they have some disadvantages such as an increased number of components, a complex pulse width modulation control method, and a voltage-balancing problem. In this paper, a novel nine-level reduced switch cascaded multilevel inverter based on a multilevel DC link (MLDCL) inverter topology with reduced switching components is proposed to improve the multilevel inverter performance by compensating the above mentioned disadvantages. This topology requires fewer components when compared to diode clamped, flying capacitor and cascaded inverters and it requires fewer carrier signals and gate drives. Therefore, the overall cost and circuit complexity are greatly reduced. This paper presents modulation methods by a novel reference and multicarrier based PWM schemes for reduced switch cascaded multilevel inverters (RSCMLI). It also compares the performance of the proposed scheme with that of conventional cascaded multilevel inverters (CCMLI). Simulation results from MATLAB/SIMULINK are presented to verify the performance of the nine-level RSCMLI. Finally, a prototype of the nine-level RSCMLI topology is built and tested to show the performance of the inverter through experimental results.

Central Control over Distributed Service Function Path

  • Li, Dan;Lan, Julong;Hu, Yuxiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.577-594
    • /
    • 2020
  • Service Function Chaining (SFC) supports services through linking an ordered list of functions. There may be multiple instances of the same function, which provides a challenge to select available instances for all the functions in an SFC and generate a specific Service Function Path (SFP). Aiming to solve the problem of SFP selection, we propose an architecture consisting of distributed SFP algorithm and central control mechanism. Nodes generate distributed routings based on the first function and destination node in each service request. Controller supervises all of the distributed routing tables and modifies paths as required. The architecture is scalable, robust and quickly reacts to failures because of distributed routings. Besides, it enables centralized and direct control of the forwarding behavior with the help of central control mechanism. Simulation results show that distributed routing tables can generate efficient SFP and the average cost is acceptable. Compared with other algorithms, our design has a good performance on average cost of paths and load balancing, and the response delay to service requests is much lower.

Novel Control of a Modular Multilevel Converter for Photovoltaic Applications

  • Shadlu, Milad Samady
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.103-110
    • /
    • 2017
  • The number of applications of solar photovoltaic (PV) systems in power generation grids has increased in the last decade because of their ability to generate efficient and reliable power in a variety of low installation in domestic applications. Various PV converter topologies have therefore emerged, among which the modular multilevel converter (MMC) is very attractive due to its modularity and transformerless features. The modeling and control of the MMC has become an interesting issue due to the extremely large expansion of PV power plants at the residential scale and due to the power quality requirement of this application. This paper proposes a novel control method of MMC which is used to directly integrate the photovoltaic arrays with the power grid. Traditionally, a closed loop control has been used, although circulating current control and capacitors voltage balancing in each individual leg have remained unsolved problem. In this paper, the integration of model predictive control (MPC) and traditional closed loop control is proposed to control the MMC structure in a PV grid tied mode. Simulation results demonstrate the efficiency and effectiveness of the proposed control model.

Routing Protocol based on Connectivity Degree and Energy Weight (연결도와 에너지 가중치 기반의 라우팅 프로토콜)

  • Jeong, Yoon-Su
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.1
    • /
    • pp.7-15
    • /
    • 2014
  • In this paper, we propose an efficient routing protocol to achieve an optimal route searching process of the network lifetime by balancing power consumption per node. The proposed protocols aim at finding energy-efficient paths at low protocol power. In our protocol, each intermediate node keeps power level and branch number of child nodes and it transmits the data the nearest neighbor node. Our protocol may minimize the energy consumption at each node, thus prolong the lifetime of the system regardless of the location of the sink outside or inside the cluster. In the proposed protocol for inter-cluster communication, a cluster head chooses a relay node from its adjacent cluster heads according to the node's residual energy and its distance to the base station. Simulation results show that proposed protocol successfully balances the energy consumption over the network, and achieves a remarkable network lifetime improvement as highly as 7.5%.

  • PDF

A Cluster-Based Relay Station Deployment Scheme for Multi-Hop Relay Networks

  • Chang, Jau-Yang;Chen, Yun-Wei
    • Journal of Communications and Networks
    • /
    • v.17 no.1
    • /
    • pp.84-92
    • /
    • 2015
  • Multi-hop relay networks have been widely considered as a promising solution to extend the coverage area and to reduce the deployment cost by deploying the relay stations (RSs) in mobile communication systems. Suitable deployment for the RSs is one of the most important features of the demand nodes (DNs) to obtain a high data transmission rate in such systems. Considering a tradeoff among the network throughput, the deployment budget, and the overall coverage of the systems, efficient RS deployment schemes and corresponding algorithms must be developed and designed. A novel cluster-based RS deployment scheme is proposed in this paper to select the appropriate deployment locations for the relay stations from the candidate positions. To make an ideal cluster distribution, the distances between the DNs are calculated when deploying the RSs. We take into account the traffic demands and adopt a uniform cluster concept to reduce the data transmission distances of the DNs. On the basis of the different candidate positions, the proposed scheme makes an adaptive decision for selecting the deployment sites of the RSs. A better network throughput and coverage ratio can be obtained by balancing the network load among the clusters. Simulation results show that the proposed scheme outperforms the previously known schemes in terms of the network throughput and the coverage ratio. Additionally, a suitable deployment budget can be implemented in multi-hop relay networks.

A Study on the CCFL Parallel Driving Circuit for the large LCD TV (대화면 LCD TV용 CCFL 병렬 구동에 관한 연구)

  • Jang, Young-Su;Yoon, Seok;Kweon, Gie-Hyoun;Han, Sang-Kyoo;Hong, Sung-Soo;Sakong, Suk-Chin;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.454-462
    • /
    • 2006
  • To enhance the competitive edge of the material cost, various techniques lowering the material cost of inverter to drive Cold Cathode Fluorescent Lamp (CCFL) have been developed. In this paper, the theoretical analysis has been done for the existing techniques such as Jin Balance and O2Micro technique. Especially, How to design the value of magnetizing inductance to meet the specification of the lamp current tolerance between lamps has been disclosed. Based on this result, two kinds of hybrid type balancing techniques have been proposed and analyzed mathematically, Also, the accuracy of the proposed techniques has been verified through Pspice simulation.

Parallelization of sheet forming analysis program using MPI (MPI를 이용한 판재성형해석 프로그램의 병렬화)

  • Kim, Eui-Joong;Suh, Yeong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.132-141
    • /
    • 1998
  • A parallel version of sheet forming analysis program was developed. This version is compatible with any parallel computers which support MPI that is one of the most recent and popular message passing libraries. For this purpose, SERI-SFA, a vector version which runs on Cray Y-MP C90, a sequential vector computer, was used as a source code. For the sake of the effectiveness of the work, the parallelization was focused on the selected part after checking the rank of CPU consumed from the exemplary calculation on Cray Y-MP C90. The subroutines associated with contact algorithm was selected as targe parts. For this work, MPI was used as a message passing library. For the performance verification, an oil pan and an S-rail forming simulation were carried out. The performance check was carried out by the kernel and total CPU time along with theoretical performance using Amdahl's Law. The results showed some performance improvement within the limit of the selective paralellization.

The Flood Control of the Namgang and Andong Reservoir System by an Optimization Procedure (최적화(最適化) 기법(技法)에 의한 남강(南江)-안동(安東)댐의 홍수조절(洪水調節))

  • Kim, Sheung Kown;Yoon, Yong Nam;Lee, Sung Yoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.49-60
    • /
    • 1988
  • The use of an Incremental Dynamic Programming (IDP) for real-time flood control operation is investigated. The optimization model has been applied for the Namgang and Andong hypothetical flood control system in the Nakdong river basin. The objective of the operation is defined to minimize the maximum flow at the confluence of downstreams from the two reservoirs. The results are compared to the direct summation of the flood routing results from individual flood control simulation run. It shows that peak flow at the confluence is reduced markedly by reducing peak outflows from individual reservoirs and by balancing the time of the peak release between the two reservoirs.

  • PDF

Model Validation and Controller Design for Vibration Suppression of Flexible Rotor Using AMB

  • Soo Jeon;Ahn, Hyeong-Joon;Han, Dong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1583-1593
    • /
    • 2002
  • This paper discusses the model validation and vibration suppression of an AMB flexible rotor via additional LQG controller. The main difficulty in the vibration suppression of the flexible rotor using AMB is to realize a controller that can minimize resonance without injuring the stabilized rigid modes. In order to solve this problem, simple scheme for system modeling and controller design are developed. Firstly, the AMB flexible rotor is stabilized with a PID controller, which leads to a new stable rotor-bearing system. Then, authors propose the model validation procedure using measured open-loop frequency responses to obtain an accurate model of the AMB flexible rotor system. After that, LQG controller with modal weighting is designed to suppress resonances of the stable rotor-bearing system. Due to the poor controllability and observability of flexible modes compared to rigid ones, balancing of two Gramians is prerequisite for the fair LQG controller design. Simulation with step disturbance and experimental results of unbalance response up to 10,000 rpm verified the effectiveness of the proposed scheme.

Convenient Thermal Modeling for Loss Distribution method of 3-Level Active NPC Inverter using Newton's Law of cooling (Active NPC 인버터의 손실 분배 제어를 위한 뉴턴의 냉각법칙 기반의 간단한 열 모델링 기법)

  • Hyun, Seung-Wook;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.71-80
    • /
    • 2015
  • This paper proposes a convenient thermal modeling method for loss distribution control method of 3-level Active NPC(Neutral Point Clamped) inverter. In the drawback of conventional 3-level NPC, the generated losses can occur unbalance in each switching device, as a result, thermal utilization of designed system has been decreased. In order to compensate unbalanced losses, Active NPC inverter performed loss balancing control with thermal modeling during operation of each switching device. Therefore, this paper deals with a convenient thermal modeling method based on newton's law of cooling rather than conventional thermal modeling method. Both simulation and experimental results based on 10kW 3-level Active NPC inverter confirm the validity of the analysis performed in the study.