• Title/Summary/Keyword: Average image difference

Search Result 436, Processing Time 0.024 seconds

Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging (뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구)

  • Lee, Hoo-Min;Kim, Ham-Gyum;Kong, Seok-Kyo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • The purpose of this research is to seek SPAIR's reversal time (TI) which satisfies two conditions ; maintaining the suppression ability of fat tissue and simultaneously minimizing the inhomogeneity of fat tissue in T2 high-speed spin echo 3.0T magnetic resonance image (MRI) of the brain, and to compare SPAIR with STIR which is fat-suppression technique. The reversal times (TI) of SPAIR protocol are set to 1/2, 1/3, 1/6 and 1/12 of SPAIR TR (420 msec), namely 210 msec (8 people), 140 msec (26 people), 70 msec (26 people) and 35 msec (18 people) and STIR TI is set with 250 msec (26 people). With these parameter sets, we acquired the axis direction 104 images of the brain. In ROI ($50\;mm^2$) of output image, signal intensities of the fatty tissue, the muscular tissue, and the background were measured and the CNRs of fatty tissue and the muscular tissue were calculated. The inhomogeneity of the fatty tissue is SD/mean, where SD is the standard deviation and 'mean' is a average fatty tissue signal. Consequently, SPAIR TI is determined on either 1/3 or 1/6 of TR (420 ms) ; 140 ms or 70 ms. Because the difference of statistics in fat-suppression ability and inhomogeneity of fatty tissue is very small (p < 0.001), Selecting 140 ms seems to be better choice for the image quality. Meanwhile, Comparing SPAIR (TI : 140 ms) with STIR, the fat-suppression is not able to be considered statistically (p < 0.252), but the image quality is able to be considered statistically (p < 0.01). In conclusion, SPAIR is better than STIR in the image quality.

  • PDF

Image analysis of Specialized Vocational high school recognized by middle school student (중학생이 인식하는 특성화 고등학교 이미지 분석)

  • Kim, Yeong-Hun;Kim, Tae-Hoon
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.114-135
    • /
    • 2013
  • The purpose of this study is to provide base line data for right concept and identity establishment of Specialized Vocational high school, to identify recognition of Specialized Vocational high school, to analyze image of Specialized Vocational high school recognized by middle school student. The population was all middle school third year students in Korea. Using random sampling technique, 50 classes of 61 schools were sampled for the study. A survey questionnaire used Semantic Differential(SD) suggested by Osgood(1957). SD consisted of a number of adjective pairs, finally, this study used 11 adjective pairs to have validity. 1,198 out of 1,441 questionnaire were returned (a return rate of 83.14%), among which 935 were used for the analysis after data cleaning. An alpha level of 0.05 was established a prior for determining significance. All data analysis was accomplished using the SPSS 20.0 Win. Based on the finding of the study, the major results of the this study were as follows : 1. Higher average is female students' image of Specialized Vocational high school than male students' that, but, The difference between the two samples was not statistically significant. 2. It was only 20% that receive career education of Vocational high school. It is necessary to accomplish and expand career education of Specialized Vocational high school for proper career education from middle school, to realize career exploration and decide one's career path based on one's specialty. 3. They have positive images who hope for going on to the Specialized Vocational high school of education than the others. 4. It is necessary to accomplish and expand career education of Specialized Vocational high school for proper career education from middle school, to realize career exploration and decide one's career path based on one's specialty, because the result was statistically significant. 5. They have the more possitive image of Specialized Vocational high school, the more know it, totally.

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Correlation Analysis of Factors Affecting the Collimator Size used during Lumbar Spine Lateral Examination in Digital Radiography System (디지털 방사선 장비에서 요추 측면 검사 시 사용되는 조사야 크기에 영향을 미치는 요인의 상관관계 분석)

  • Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.345-353
    • /
    • 2024
  • The purpose of this study was to suggest an appropriate collimation size and central X-ray incidence point by analyzing the correlation between the collimation size used in lumbar lateral examination and factors affecting the collimation size. the lumbar lateral examination results of 148 patients suitable for the purpose of this study were analyzed. The measurement method was to set the total horizontal width shown in the image to the size of the irradiation field(collimation) used during the examination. The distance connected vertically from the end of the dorsal field to the apophyseal joint of the third lumbar vertebra(AJD), the distance from the dorsal end of the image field to the center of the body of the third lumbar vertebra(BD), and the distance from the end of the dorsal field of the image to the center of the pedicle of the third lumbar vertebra(PD). The distance was measured. For comparative analysis of the mean values of dependent variables according to gender, age, height, weight, and body mass index, the mean values were compared using the independent samples t test and one-way ANOVA. For post hoc analysis, duncan was used. The correlation between independent and dependent variables was analyzed using Pearson correlation analysis. In this study, statistical significance was set at a p value of 0.05 or lower. The average value of the collimation size during the lumbar spine lateral examination was 252.45 mm, AJD was 102.11 mm, BD was 141.17 mm, and PD was 119.73 mm. The mean values of collimation size, AJD, BD, and PD were larger in men than in women, but statistical significance for the difference in mean values by gender was found only in BD (p<0.05). There was a slight difference in the mean value of each group according to age, but there was no statistical significance (p>0.05). The collimation size and mean values of AJD, BD, and PD according to height, weight, and body mass index differed depending on the independent variables, and the differences were all statistically significant (p<0.05). As a result of the correlation analysis, field size and AJD, BD, and PD showed no correlation with gender and age, a weak positive correlation with height, and a medium positive correlation with weight and body mass index. The results of this study showed that CS was correlated with height, weight, and BMI during lumbar lateral examination. If the entrance point of the central X-ray is moved to the appophyseal joint by considering weight and BMI when adjusting the collimation size in clinical practice, it is expected that the collimation size can be reduced bu about 5%.

Diurnal Change of Reflectance and Vegetation Index from UAV Image in Clear Day Condition (청천일 무인기 영상의 반사율 및 식생지수 일주기 변화)

  • Lee, Kyung-do;Na, Sang-il;Park, Chan-won;Hong, Suk-young;So, Kyu-ho;Ahn, Ho-yong
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.735-747
    • /
    • 2020
  • Recent advanced UAV (Unmanned Aerial Vehicle) technology supply new opportunities for estimating crop condition using high resolution imagery. We analyzed the diurnal change of reflectance and NDVI (Normalized Difference Vegetation Index) in UAV imagery for crop monitoring in clear day condition. Multi-spectral images were obtained from a 5-band multi-spectral camera mounted on rotary wing UAV. Reflectance were derived by the direct method using down-welling irradiance measurement. Reflectance using UAV imagery on calibration tarp, concrete and crop experimental sites did not show stable by time and daily reproducible values. But the CV (Coefficient of Variation) of diurnal NDVI on crop experimental sites was less than 5%. As a result of comparing NDVI at the similar time for two day, the daily mean average ratio of error showed a difference of 0.62 to 3.97%. Therefore, it is considered that NDVI using UAV imagery can be used for time series crop monitoring.

Analysis of Drapability of Men's & Women's Suit Fabrics (남녀 수트직물의 드레이프성 분석)

  • Lee, Mee-Sik;Kim, Eui-Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.12 s.159
    • /
    • pp.1723-1729
    • /
    • 2006
  • Drapability is an important factor determining the end-use of fabrics. In this research, characteristics of drapability of men's and women's suit fabrics were analyzed. The hand and the preference for suit fabrics were measured by the subjective and objective evaluations. To find out the details of the drapability characteristics of suit fabrics, the drape was measured by using Cusick drape tester and was processed by image analysis software. Seasonal difference was obvious both in men's and women's fabrics. The average drape ratio of women's S/S suit fabrics showed the highest value, 0.724, then decreased in the order of men's F/W> men's S/S> women's FW. Wave amplitude showed the same order to the drape ratio. Men's fabrics were more drapable in spring and summer season rather than in fall and winter season. Women's fabrics showed the opposite trend, in other words, S/S suit fabrics were less drapable than F/W fabrics. There was also a significant difference in drape ratio between men's and women's fabrics regardless of season. For S/S, men's fabrics were more drapable than women's ones, whereas, for F/W, women's fabrics were more drapable.

A Study on Real-time Implementing of Time-Scale Modification (음성 신호 시간축 변환의 실시간 구현에 관한 연구)

  • Han, Dong-Chul;Lee, Ki-Seung;Cha, Il-Hawan;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.50-61
    • /
    • 1995
  • A time scale modification method yielding rate-modified speech while conserving the characteristic of speech was implemented in real-time using a goneral purpose digital signal processor. Time scale modification changed pronunciation speed only, producing a time difference between the input signal and the modified signal, making it impossible to implement it in real-time. In this thesis, a system was implemented to remove the time difference between the input and modified signals. Speech signals slowed down or speeded up by a physical time scale modification method, such as adjusting the motor speed of the cassett tape recorder, was used as the input signal. Physical modification that controled only the inter speed of the cassette tape player distorted the pitch period of the original speech. In this study, a real-time system was implemented so that the pitch-distorted speech was reconstructed back to the original by fractional sampling pitch shifting using an FIR filter, and this signal was time scale modified to match the cassette tape recorder motor speed using SOLA time-scale medification. In experiments using speech signals medifiedby the proposed method, results obtained using a 16-bit resolution ADSP2101 processor and using computer simulations employing floating point operations showed about the same average frame signal-to-noise ratio of about 20 dB.

  • PDF

A Study on the Influence of Consumer Type on Consumer Intention to Purchase Eco-friendly Vehicles in the Service Management of Convergence Industry (융복합 산업의 서비스경영에서 소비자 유형이 소비자의 친환경자동차에 대한 구매의도에 미치는 영향에 관한 연구)

  • Yim, Ki-Heung
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.221-232
    • /
    • 2017
  • In recent years, the development and market participation of major makers of next-generation eco-friendly vehicles has been accelerating. Consumer interest has also increased. Consumer characteristics, consumption type, characteristics of next-generation eco-friendly vehicles, and government policies on next-the results of this study are as follows. As a result of this study, it was found that the characteristics of consumers (by sex, age, monthly average income), types of consumers (price value pursuit type, individual value pursuit type), There was no significant difference between the consumers, and the purchasing intention was not significantly different by gender, age, and monthly income, but there was a significant difference in purchase intention according to the type of consumer. The positive effects of consumer purchase behavior on brand image, color, design, etc, have positive (+) effect on eco - friendly vehicles. And social environment value seeking type among consumer types are significant in relation to purchase intention. To have three support the government's carbon dioxide (per ton of 5,000 won, per ton of 10,000 won), national or local government vehicle price support directly gasolin tax, disel tax, carbon taxes, such as fuel-related tax relief, etc. was found to have positive effect.

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.