• 제목/요약/키워드: Average heart beat

검색결과 21건 처리시간 0.035초

Heart Axis Rotation Due to Exercise

  • Lee, Tae-Jun
    • Journal of Preventive Medicine and Public Health
    • /
    • 제4권1호
    • /
    • pp.1-18
    • /
    • 1971
  • Eleven nonathletes and eleven athletes were exercised on a standardised Harvard step test, and the average rate of change in QRS amplitude in lead III of the electocardiogram associated with heart rotation and the average change in rate of heart beat were observed. 1. After the Harvard step exercise, the average rate of change in QRS amplitude in lead III of both groups increased. This was due to the clockwise rotation of the heart and was associated with respiratory movement. The diaphragm was inferred to remain for a while in a relatively more inspiratory position. 2. After the Halved step exercise, a high correlation between the recovery of the average rate of change in QRS amplitude in lead III and the average change in rate of heart beat was observed in the athletic group. 3. In the nonathletic group there was no significant correlation between the average rate of QRS amplitude change and the average rate of change of heart beat. 4. Athletes were assumed to be trained to ventilate quickly at their maximum ability, using deep descending movements of the diaphragm and other respiratory musclature. Consequently, the average in rate of heart beat also recovered quickly. 5. Nonathletes were inferred not to have been trained to adjust quickly to ventilate so efficiently with their diaphragm movement and other respiratory musculature, and are characterised by their longer time to complete recovery.

  • PDF

체장에 따른 향어, Cyprinus carpio의 심전도 (Response of Electrocardiogram to Mirror carp, Cyprinus carpio of Body Length)

  • 김영기;양용림;안영일
    • 수산해양기술연구
    • /
    • 제38권4호
    • /
    • pp.284-288
    • /
    • 2002
  • 향어, Cyprinus carpio [Linnaeus]의 체장에 따른 심전도를 구명하기 위하여, 어체내에 전극을 삽입하여 3가지 체장 범위 (10~15, 15~20, 20~25cm)에서의 심전도를 주간과 야간으로 구분하여, 16~18$^{\circ}C$ 수온에서 30분간 조사한 심박수와 생체전위를 마취상태와 안정상태로 구분비교 분석한 결과는 다음과 같다. 1 체장이 10~15 cm인 경우, 마비상태 (0~9분)에서의 평균심박수는 주간에 43.4 beat/min, 야간에 45.9 beat/min였고, 평균생체전위는 주간에 4.38 $\mu\textrm{V}$, 야간에 3.64 $\mu\textrm{V}$로 나타났으며, 안정상태 (9~30분)에서의 평균심박수는 주간에 69.4 beat/min, 야간에 67.4 beat/min였고, 평균생체전위는 주간에 3.82 $\mu\textrm{V}$, 야간에 3.50 $\mu\textrm{V}$로 나타났다. 2 체장이 15~20cm인 경우, 마비상태 (0~5분)에서의 평균심박수는 주간에 42.2 beat/min, 야간에 45.4 beat/min였고, 평균생체전위는 주간에 4.13 $\mu\textrm{V}$, 야간에 3.95 $\mu\textrm{V}$로 나타났으며, 안정상태(5~30분)에서의 평균심박수는 주간에 67.6 beat/min, 야간에 65.3 beat/min였고, 평균생체전위는 주간에 4.58 $\mu\textrm{V}$, 야간에 4.61 $\mu\textrm{V}$로 나타났다. 3. 체장이 20~25 cm인 경우, 마비상태(0~4분)에서의 평균심박수는 주간에 47.5 beat/min, 야간에 47.5 beat/min였고, 평균생체전위는 주간에 4.81 $\mu\textrm{V}$, 야간에 4.20 $\mu\textrm{V}$로 나타났으며, 안정상태(4~30분)에서의 평균심박수는 주간에 67.5 beat/min, 야간에 64.8 beat/min였고, 평균생체전위는 주간에 5.31 $\mu\textrm{V}$, 야간에 4.90 $\mu\textrm{V}$로 나타났다.

전기자재에 대한 역돔의 심전도 (Response of Electrocardiogram of Nile tilapia, Oreochromis niloticus to Electric Stimulus)

  • 한규환;양용림
    • 수산해양기술연구
    • /
    • 제38권4호
    • /
    • pp.278-283
    • /
    • 2002
  • 전기자극에 대한 역돔, Oreochromis niloticus[Linnaeus]의 심전도를 구명하기 위하여, 어체내에 전극을 삽입하여 3 가지 전기자극원(20, 30, 40 Vp ; 10 msec)으로 실험어에 자극을 가하였을 때의 심전도를 서간과 야간으로 구분하여 60분간 조사한 심박수와 생체전위를 자극 전(마취상태, 안정상태)과 자극 후(자극-회복상태, 회복상태)로 구분하여 비교 분석한 결과는 다음과 같다. 1. 역돔은 마취 후 3 분 뒤에 안정상태에 도달하였고, 안정상태에서의 평균상심박수는 서간에 45.8 beat/min, 야간에 45.0 beat/min였고, 평균생체전위는 서간에 1.76 $\mu\textrm{V}$, 야간에 1.75 $\mu\textrm{V}$였다. 2. 자극별 평균심박수는 \circled1 자극-회복상태에서 전기자극이 20 Vp인 경우, 서간에 34.9 beat/min, 야간에 33.4 beat/min였고, 30 Vp인 경우, 서간에 36.8 beat/min, 야간에 36.0 beat/min였으며, 40Vp인 경우 서간에 38.0 beat/min, 야간에 36.4 beat/min로 나타났다. \circled2 회복상태에서 전기자극이 20 Vp인 경우, 서간에 45.5 beat/min, 야간에 45.1 beat/min였고, 30 Vp인 경우, 서간에 47.9 beat/min, 야간에 49.0 beat/min 였으며, 40 Vp인 경우, 서간에 51.4 beat/min, 야간에 50.7 beat/min로 나타났다. 3. 자극별 평균생체전위는 \circled1 자극-회복상태에서 전기자극이 20Vp인 경우, 서간에 2.54$\mu\textrm{V}$ 야간에 2.39$\mu\textrm{V}$였고,30Vp인 경우, 서간에 3.30$\mu\textrm{V}$, 야간에 2.30 $\mu\textrm{V}$였으며, 40Vp 인 경우 서간에 6.05 $\mu\textrm{V}$, 야간에 3.23 $\mu\textrm{V}$로 나타났다. \circled2 회복상태에서 전기자극이 20 Vp인 경우, 서간에 1.92 $\mu\textrm{V}$, 야간에 1.95 $\mu\textrm{V}$ 였고, 30 Vp인 경우, 서간에 2.78 $\mu\textrm{V}$, 야간에 2.21 $\mu\textrm{V}$ 였으며, 40 Vp인 경우 서간에 3.60$\mu\textrm{V}$ 야간에 2.98$\mu\textrm{V}$로 나타났다.

심혈관 신호에 있어서 단기간 beat-to-beat 변이의 비선형 역할에 관한 연구 (Study on Nonlinearites of Short Term, Beat-to-beat Variability in Cardiovascular Signals)

  • Han-Go Choi
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권3호
    • /
    • pp.151-158
    • /
    • 2003
  • 심장혈관 신호에 있어서 단기간의 beat-to-beat 변이(variability)에 대한 여러 연구에서 선형 분석기법들이 사용되었다. 그러나 단기간 beat-to-beat 변이에 대해 선형기법 사용의 타당성에 대한 연구나 선형과 비선형 특성을 비교한 연구는 수행되지 않았다. 본 논문의 목적은 단기간 beat-to-beat 변이의 비선형성 특성을 조사함으로써 선형기법 사용의 적절함을 증명하고자 한다. 이를 위해 선형 ARMA와 비선형 신경망(NN) 모델을 사용하여 예측을 수행하였는데, 과거의 순시 심박(HR)과 평균 혈압(BP)으로부터 현재의 심박과 혈압 예측을 상호 비교하였다. 이러한 예측모델을 평가하기 위해 MIMIC 데이터베이스로부터 HR와 BP 시계열을 사용하였다. 실험결과에 의하면 신경망에 의한 비선형성은 단기간 beat-to-beat 변이를 생성하는 시스템 동특성을 나타내는데 의미있는 역할을 하지 못하였으며, 이 사실은 ARMA 선형 분석기법이 이러한 시스템 동특성을 나타내는데 적절함을 보여주고 있다

Stress Identification and Analysis using Observed Heart Beat Data from Smart HRM Sensor Device

  • Pramanta, SPL Aditya;Kim, Myonghee;Park, Man-Gon
    • 한국멀티미디어학회논문지
    • /
    • 제20권8호
    • /
    • pp.1395-1405
    • /
    • 2017
  • In this paper, we analyses heart beat data to identify subjects stress state (binary) using heart rate variability (HRV) features extracted from heart beat data of the subjects and implement supervised machine learning techniques to create the mental stress classifier. There are four steps need to be done: data acquisition, data processing (HRV analysis), features selection, and machine learning, before doing performance measurement. There are 56 features generated from the HRV Analysis module with several of them are selected (using own algorithm) after computing the Pearson Correlation Matrix (p-values). The results of the list of selected features compared with all features data are compared by its model error after training using several machine learning techniques: support vector machine, decision tree, and discriminant analysis. SVM model and decision tree model with using selected features shows close results compared to using all recording by only 1% difference. Meanwhile, the discriminant analysis differs about 5%. All the machine learning method used in this works have 90% maximum average accuracy.

광자극에 대한 역돔의 심전도 (Response of Electrocardiogram of Nile tilapia, Oreochromis niloticus to Light Stimuli)

  • 김영기;양용림
    • 수산해양기술연구
    • /
    • 제38권3호
    • /
    • pp.217-225
    • /
    • 2002
  • 광자극에 대한 역돔, Oreochromis niloticus[Linnaeus]의 심전도를 구명하기 위하여 16~18$^{\circ}C$ 수온에서 어체내에 전극을 삽입하여 3가지 광자극 (10, 100, 400 lu$\chi$)에 대한 심전도를 서간과 야간으로 구분하여 60분간 연속적으로 조사한 심전도를 상태별로 분석한 심박수와 생체전위는 다음과 같다. 1. 역돔은 마취 후 3분 뒤에 안정상태에 도달하였고, 안정상태에서 평균심박수는 서간에 47.6 beat/min, 야간에 45.1 beat/min였고, 평균생체 전위는 서간에 1.04 $\mu\textrm{V}$, 야간에 1.24 $\mu\textrm{V}$로 나타났다. 2 자극별 평균심박수는 \circled1 자극상태에서, 10 lu$\chi$인 경우 서간에 39.7 beat/min, 야간에 38.2 beat/min였고, 100 lu$\chi$인 경우 서간에 38.7 beat/min, 야간에 36.9 beat/min였으며, 400 lu$\chi$인 경우 서간에 36.8 beat/min, 야간에 35.8 beat/min로 나타났고, \circled2 회복상태에서, 10 lu$\chi$인 경우 서간에 47.1 beat/min, 야간에 46.0 beat/min였고, 100 lu$\chi$인 경우 서간에 47.2 beat/min, 야간에 45.6 beat/min였으며, 400 lu$\chi$인 경우 서간에 48.1 beat/min, 야간에 46.6 beat/min로 나타났다. 3. 자극별 평균생체전위는 \circled1 자극상태에서, 10 lu$\chi$인 경우 서간에 1.22 $\mu\textrm{V}$, 야간에 0.71$\mu\textrm{V}$였고, 100 lu$\chi$인 경우 서간에 0.63 $\mu\textrm{V}$, 야간에 0.90 $\mu\textrm{V}$였으며, 400 lu$\chi$ 인 경우 서간에 1.39 $\mu\textrm{V}$, 야간에 1.63 $\mu\textrm{V}$로 나타났고, \circled2 회복상태에서, 10 lu$\chi$인 경우 서간에 1.26 $\mu\textrm{V}$, 야간에 1.59 $\mu\textrm{V}$였고, 100 lu$\chi$인 경우 서간에 2.63 $\mu\textrm{V}$ 야간에 3.65 $\mu\textrm{V}$였으며, 400 lu$\chi$인 경우 서간에 2.52 $\mu\textrm{V}$, 야간에 3.67 $\mu\textrm{V}$로 나타났다.

광 자극에 대한 향어의 심전도 (Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli)

  • 양용림;김영기
    • 수산해양기술연구
    • /
    • 제37권2호
    • /
    • pp.124-132
    • /
    • 2001
  • 광 자극에 대한 향어, Cyprinus carpio [Linnaeus]의 심전도를 규명하기 위하여, 어체내에 전극을 삽입하여 3가지 광 자극 (10,100,400 lux)에 대하여 심전도를 주간과 야간으로 구분하여 60분간 연속적으로 조사한 심전도를 현황별로 분석한 심전수와 생체전위는 다음과 같다. 1. 향어는 마취후 5분 뒤에 안정상태에 도달하였고, 안정상태에서 평균심전수는 주간에 64.9 beat/min, 야간에 65.3 beat/min였고, 평균생체전위는 주간에 36.9 nV, 야간에 32.9nV로 나타났다. 2. 자극별 평균 심박수는 1) 자극상태에서, 10 lux인 경우 주간에 68.7 beat/min, 야간에 46.0 beat/min였고, 100 lux인 경우 주간에 53.4 beat/min, 야간에 44.1 beat/min였으며, 400 lux인 경우 주간에 53.2 beat/min, 야간에 40.1 beat/min로 나타났고, 2) 회복상태에서, 10 lux인 경우 주간에 67.9 beat/min, 야간에 57.2 beat/min였고, 100 lux인 경우 주간에 68.8 beat/min, 야간에 61.0 beat/min였으며, 400 lux인 경우 주간에 69.6 beat/min, 야간에 63.6 beat/min로 나타났다. 3. 자극별 평균생체전위는 1) 자극상태에서, 10lux인 경우 주간에 59.1 nV, 야간에 24.0 nV였고, 100 lux인 경우 주간에 26.8 nV, 야간에 45.6 nV였으며, 400 lux인 경우 주간에 71.7 nV, 야간에 14.4 nV로 나타났고, 2) 회복상태에서, 10 lux인 경우 주간에 38.8 nV, 야간에 27.3 nV였고, 100 lux인 경우 주간에 29.0 nV, 야간에 39.3 nV였으며, 400 lux인 경우 주간에 66.1 nV, 야간에 21.4 nV로 나타났다.

  • PDF

WPAN에서의 신속한 망 복구를 위한 능동적인 PNC 핸드오버방법 및 PNC Heart Beat 의 비컨 프레임 정렬 방식의 성능분석 (Performance of active PNC Handover and PNC Heart Beat based Beacon Alignment Schemes for Wireless PAN Systems)

  • 남혜진;김재영;전영애;이형수;김세한;윤종호
    • 한국통신학회논문지
    • /
    • 제31권2B호
    • /
    • pp.117-128
    • /
    • 2006
  • 일반적인 IEEE 802.15.3 WPAN에서는 피코넷을 관리하던 PicoNet Coordinator(PNC)가 비정상적으로 망을 떠나게 되거나, 두 개 이상의 피코넷들이 인접해 있을 때 각 PNC로부터 주기적으로 송신되는 비컨 프레임들 사이에 충돌이 발생하게 되면, 각 피코넷에 속한 단말들이 해당 비컨 프레임을 수신하지 못하게 되면서 피코렛의 동작이 와해되는 심각한 문제가 있다. 본 논문에서는 이러한 문제를 해결하기 위하여, 다음과 같은 두 가지의 방안을 제안하였다. 첫 번째는 PNC의 비정상적인 이탈에 대비하기 위해서 각 단말들이 능동적으로 프로브 프레임을 전송하여 해당 PNC의 동작여부를 확인하도록 함으로써 신속히 새로운 PNC를 선출하는 능동적 PNC 핸드오버 방법인 Active Seamless Coordinator Switching(ASCS) 방식이다. 두 번째는 밀집된 피코넷들의 각 PNC가 주기적으로 전송하는 비컨 프레임간의 충돌을 방지하기 위한 것으로써, 각 PNC들이 해당 피코넷의 수퍼프레임 정보를 수납한 Heart Beat(HB) 프레임을 비 주기적으로 전송하여 PNC의 비컨 프레임 송신시점을 조정하도록 함으로써 비컨 프레임간의 충돌을 방지하는 PNC Heart Beat 기반의 비컨 프레임 정렬(PNC HB based Beacon Alignment) 방식이다. 제안된 두 가지 방안에 대하여 모의실험을 통해 성능을 평가한 결과, 각 방식들은 유사한 기존 방식에 비해 피코넷의 와해기간을 단축시킬 수 있어, 각 단말이 겪는 프레임당 평균 지연시간과 수퍼프레임 별 전송효율이 향상됨을 확인하였다. 특히, 제안된 방식은 WPAN규격에서 허용되는 프레임들을 활용할 수 있으므로, 구현성이 높은 장점이 있다.

심전도 신호에서 QRS 군의 왜곡에 기반한 PVC 검출 (PVC Detection Based on the Distortion of QRS Complex on ECG Signal)

  • 이승민;김진섭;박길흠
    • 한국통신학회논문지
    • /
    • 제40권4호
    • /
    • pp.731-739
    • /
    • 2015
  • 부정맥 심전도 신호에는 전도장애 및 발생부위에 따라 다양한 비정상 모양을 띄는 특이심박들이 포함되어 있고, 이들 특이심박은 부정맥 등의 심장질환을 진단하는데 있어 매우 중요하다. 본 논문에서는 심실질환에 관련한 PVC 특이심박 검출 알고리즘을 제안한다. PVC 특이심박에서는 심전도 신호의 구성요소 가운데 QRS 군의 왜곡이 발생하는 특징이 있다. 따라서 QRS 군의 왜곡 정도에 따라 PVC 특이심박을 검출할 수 있다. 먼저 R-peak의 전위, 첨도, 주기를 사용하여 QRS 군의 왜곡을 정량화하고, 이들 값들의 평균과 표준편차를 이용하여 정상 심박과의 왜곡의 정도에 따라 PVC 특이심박을 검출한다. 제안한 알고리즘은 MIT-BIH 부정맥 데이터베이스 중 심실질환과 관계되는 AAMI-V class 타입의 특이심박을 평균 98% 이상을 검출할 수 있었다.

새로운 앙상블 평균법에 의한 임피던스 심장기록법의 트래드밀 운동 중의 심박출량 측정 (Measurement of cardiac output during treadmill exercise by impedance cardiography with a new ensemble average)

  • 김덕원;송철규;오인식;황수관;김원기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 춘계학술대회
    • /
    • pp.7-8
    • /
    • 1990
  • In this study, a new ensemble average technique was developed to measure cardiac output during treadmill exercise. Each dZ/dt peak (C point) was used as a starting point for ensemble averaging, instead of conventionally used R wave of ECG in order to prevent the peak dZ/dt waveform from blurring. In ease of using R wave as a reference, time interval from R wave to the peak of dZ/dt varies for each heart beat. Stroke volume, heart rate, and cardiac output of five male were successfully measured with Balke protocol using the new ensemble average technique.

  • PDF