• 제목/요약/키워드: Auxiliary power system

검색결과 423건 처리시간 0.023초

개선된 ZVT AC/DC PFC Boost 컨버터 (Improved ZVT AC/DC PFC Boost Converter)

  • 유종규;김용;배진용;계상범;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-175
    • /
    • 2005
  • Recently international regulations governing the amount of harmonic currents(e.g IEC 61000-3-2) became mandatory and active Power factor correction (PFC) pre-regulator circuit became inevitable for the AC/DC converters. Among these topologies, the boost topology represents an optimum solution for a PFC pre-regulation in a high power application. This paper propose improved ZVT(Zero Voltage Transition) AC/DC PFC Boost using the average current control employing a soft-switching technique of the auxiliary switch with a minimum number of components. The conventional ZVT PFC Boost Converter has a disadvantage that the auxiliary switch turns off hard, which influences the overall efficiency and the EMI problem. In this paper, an improved ZVT PFC Boost converter using active snubber is proposed to minimize the switching loss of the auxiliary. The prototype of 100kHz, 640W system was implemented to show the improved performance.

  • PDF

PV용 계통연계형 인버터의 새로운 Topology 고찰 (Inquiry of New Topology for Grid-connected Photovoltaic Inverter)

  • 정영석;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.248-251
    • /
    • 1999
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper propose transformerless system topology an inquiry the validity using simulation.

  • PDF

소형전자계산기에 의한 대전력계통의 고장해석 (Analysis of Faults of Large Power System by Memory-Limited Computer)

  • 박영문
    • 전기의세계
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 1972
  • This paper describes a new approach for minimizing working memory spaces without loosing too much amount of computing time in the analysis of power system faults. This approach requires the decomposition of alrge power system into several small groups of subsystems, forms individual bus impedance matrics, store them in the auxiliary memory, later assembles them to the original total system by algorithms. And also the approach uses techniques for diagonalizing primitive impedances and expanding the system bus impedance matrices by adding a fault bus. These scheme ensures a remarkable savings of working storage and continous computations of fault currents and voltages with the voried fault locations.

  • PDF

Induction Heated Load Resonant Tank High Frequency Inverter with Asymmetrical Auxiliary Active Edge-Resonant Soft-Switching Scheme

  • Saha Bishwajit;Fathy Khairy;Kwon Soon-Kurl;Lee Hyun-Woo;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.200-202
    • /
    • 2006
  • In this paper, a novel type of auxiliary active snubbing circuit assisted quasi-resonant soft-switching pulse width modulation inverter is proposed for consumer induction heating equipments. The operation principle of this high frequency inverter is described using switching modes and equivalent circuits. This newly developed series resonant high frequency inverter can regulate its high frequency output AC power under a principle of constant frequency active edge resonant soft-switching commutation by asymmetrical PWM control system. The high frequency power regulation and actual power conversion efficiency characteristics of consumer induction heating (IH) products using the proposed soft-switching pulse width modulation (PWM) series load resonant high frequency inverter evaluated. The practical effectiveness and operating performance of high frequency inverter are discussion on the basis of simulation and experimental results as compared with the conventional soft-switching high frequency inverter.

  • PDF

계통연계형 태양광 발전 시스템에서의 전원측 역율 개선 (Source Side Power Factor Correction for Utility Interactive Photovoltaic System)

  • 조영준;김홍성;목형수;최규하;김한성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.386-392
    • /
    • 1997
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reserve margin in summer. As one of the remedies about this problem, the small scale utility interactive photovoltaic system(UIPVS) is considered for auxiliary power source. For this system one of problems to be solved technically, system operating power factor. Generally in case of small scale system, system is operated in unity power factor. But this unity power factor operating mode decrease power factor viewed from utility because UIPVS supply active power to utility. Therefore this paper propose UIPVS with power factor correcting function and this system is analyzed.

  • PDF

동력저장장치를 이용한 풍력발전 보상 시스템 설계에 관한 연구 (A Study on Design of the Compensation System for Wind Energy Generation by Power Storage Apparatus)

  • 윤석암;차인수;백행래
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.43-48
    • /
    • 2001
  • 기존의 풍력발전시스템은 풍속이 감소되면 블레이드가 저속으로 회전하기 때문에 보조발전의 도움이 없이는 자가 발전이 어려워서 한정된 풍속 조건에서만 작동이 가능하며, 풍속의 특성 때문에 풍력에너지의 이용효율이 대부 분 매우 낮다는 문제점이 있다 이와 같은 종래의 문제점을 해결하고 지역이나 지형에 크게 구애됨이 없이 풍속에 의해 발전이 이루어지다가 풍속의 저하로 출력된 전력이 적어지면 태엽에 저장된 회전에너지로 소형발전기를 운전 하여 축전지에 전력을 저장하여 부하에 전력을 연속적으로 공급하게 한다. 본 논문에서는 동력저장장치와 풍력발전기로 구성된 시스템을 설계 제작하여 풍력발전의 보상을 위한 동력저장 장치 시스템의 동작 특성을 분석하였다.

  • PDF

고효율 특성을 갖는 양방향 공진컨버터 (High Efficiency Resonant Converter for Bidirectional Power Transfer)

  • 박준형;이승민;김은수;황인갑;공영수
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.429-436
    • /
    • 2013
  • In this paper, For achieving the high gain and resonant characteristics in both of the power flow directions, a bidirectional resonant dc-dc converter with auxiliary switches is proposed. Auxiliary switches are connected in the primary and secondary side of the bidirectional resonant dc-dc converter, respectively. A 800W prototype bidirectional resonant dc-dc converter for interfacing the 400V DC buses in the energy storage system is built and tested to verify the validity and applicability of this proposed converter.

보조권선을 사용한 자동차 헤드라이트용 고압방전등 안정기 (Automotive HID ballast using auxiliary winding)

  • 이규찬;조보형
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.449-454
    • /
    • 1999
  • 본 논문에서는 자동차 헤드라이트용 고압방전등 안정기의 새로운 전력변환 구조를 제안한다. 제안된 전력변환 구조는 기존의 안정기와 같이 고압방전등의 전력제어를 하는 고주파 DC-DC 컨버터와 저주파 DC-AC 인버터로 구성되어 있지만, 컨버터에 보조권선을 사용하여 고압방전등의 점등개시용 절연파괴전압을 얻기 위한 고압변압기의 1차측 전압을 DC-DC 컨버터의 직류단과 분리하여 공급하게 되어 있다. 따라서 기존의 시스템에 비해 작은 전압 정격을 가지는 소자를 사용할 수 있어 시스템의 효율 향상 및 가격 절감을 할 수 있다.

  • PDF

HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로 (Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System)

  • 정재헌;조한제;구법진;노의철;정용호;백승택
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.