• Title/Summary/Keyword: Auxiliary power system

Search Result 424, Processing Time 0.028 seconds

Improved ZVT AC/DC PFC Boost Converter (개선된 ZVT AC/DC PFC Boost 컨버터)

  • Ryu, Jong-Gyu;Kim, Yong;Bae, Jin-Yong;Gye, Sang-Bum;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.172-175
    • /
    • 2005
  • Recently international regulations governing the amount of harmonic currents(e.g IEC 61000-3-2) became mandatory and active Power factor correction (PFC) pre-regulator circuit became inevitable for the AC/DC converters. Among these topologies, the boost topology represents an optimum solution for a PFC pre-regulation in a high power application. This paper propose improved ZVT(Zero Voltage Transition) AC/DC PFC Boost using the average current control employing a soft-switching technique of the auxiliary switch with a minimum number of components. The conventional ZVT PFC Boost Converter has a disadvantage that the auxiliary switch turns off hard, which influences the overall efficiency and the EMI problem. In this paper, an improved ZVT PFC Boost converter using active snubber is proposed to minimize the switching loss of the auxiliary. The prototype of 100kHz, 640W system was implemented to show the improved performance.

  • PDF

Inquiry of New Topology for Grid-connected Photovoltaic Inverter (PV용 계통연계형 인버터의 새로운 Topology 고찰)

  • 정영석;유권종
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.248-251
    • /
    • 1999
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper propose transformerless system topology an inquiry the validity using simulation.

  • PDF

Analysis of Faults of Large Power System by Memory-Limited Computer (소형전자계산기에 의한 대전력계통의 고장해석)

  • Young Moon Park
    • 전기의세계
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 1972
  • This paper describes a new approach for minimizing working memory spaces without loosing too much amount of computing time in the analysis of power system faults. This approach requires the decomposition of alrge power system into several small groups of subsystems, forms individual bus impedance matrics, store them in the auxiliary memory, later assembles them to the original total system by algorithms. And also the approach uses techniques for diagonalizing primitive impedances and expanding the system bus impedance matrices by adding a fault bus. These scheme ensures a remarkable savings of working storage and continous computations of fault currents and voltages with the voried fault locations.

  • PDF

Induction Heated Load Resonant Tank High Frequency Inverter with Asymmetrical Auxiliary Active Edge-Resonant Soft-Switching Scheme

  • Saha Bishwajit;Fathy Khairy;Kwon Soon-Kurl;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.200-202
    • /
    • 2006
  • In this paper, a novel type of auxiliary active snubbing circuit assisted quasi-resonant soft-switching pulse width modulation inverter is proposed for consumer induction heating equipments. The operation principle of this high frequency inverter is described using switching modes and equivalent circuits. This newly developed series resonant high frequency inverter can regulate its high frequency output AC power under a principle of constant frequency active edge resonant soft-switching commutation by asymmetrical PWM control system. The high frequency power regulation and actual power conversion efficiency characteristics of consumer induction heating (IH) products using the proposed soft-switching pulse width modulation (PWM) series load resonant high frequency inverter evaluated. The practical effectiveness and operating performance of high frequency inverter are discussion on the basis of simulation and experimental results as compared with the conventional soft-switching high frequency inverter.

  • PDF

Source Side Power Factor Correction for Utility Interactive Photovoltaic System (계통연계형 태양광 발전 시스템에서의 전원측 역율 개선)

  • 조영준;김홍성;목형수;최규하;김한성
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.386-392
    • /
    • 1997
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reserve margin in summer. As one of the remedies about this problem, the small scale utility interactive photovoltaic system(UIPVS) is considered for auxiliary power source. For this system one of problems to be solved technically, system operating power factor. Generally in case of small scale system, system is operated in unity power factor. But this unity power factor operating mode decrease power factor viewed from utility because UIPVS supply active power to utility. Therefore this paper propose UIPVS with power factor correcting function and this system is analyzed.

  • PDF

A Study on Design of the Compensation System for Wind Energy Generation by Power Storage Apparatus (동력저장장치를 이용한 풍력발전 보상 시스템 설계에 관한 연구)

  • 윤석암;차인수;백행래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. In addition, most of them have very low usage efficiency because of the characteristic changes of wind. For the solution of these problems and for enough generation regardless of districts and geographical features the rotation energy stored in a spring drives a compact generator and then electric power is stored at battery and supplied to the load continuously according to the lack of wind force. In this paper, the fabricated system consisting of a wind generator and power storage apparatus was introduced and its operation characteristics were analyzed.

  • PDF

High Efficiency Resonant Converter for Bidirectional Power Transfer (고효율 특성을 갖는 양방향 공진컨버터)

  • Park, Jun-Hyoung;Lee, Seung-Min;Kim, Eun-Soo;Hwang, In-Gab;Kong, Young Su
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.429-436
    • /
    • 2013
  • In this paper, For achieving the high gain and resonant characteristics in both of the power flow directions, a bidirectional resonant dc-dc converter with auxiliary switches is proposed. Auxiliary switches are connected in the primary and secondary side of the bidirectional resonant dc-dc converter, respectively. A 800W prototype bidirectional resonant dc-dc converter for interfacing the 400V DC buses in the energy storage system is built and tested to verify the validity and applicability of this proposed converter.

Automotive HID ballast using auxiliary winding (보조권선을 사용한 자동차 헤드라이트용 고압방전등 안정기)

  • 이규찬;조보형
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.449-454
    • /
    • 1999
  • A new scheme of the automotive High Intensity Discharge (HlD) lamp ballast systems is proposed. The p proposed scheme consists of the high frequency IX DC converter and the low frequency DC-AC inverter, like t that the conventional HID ballast system. However, this system separates the input voltage of the ignitor from t the dc link voltage, which results in the use of lower voltage rating power devices for the HID lamp ballast s system, comparlu with convention띠 system. As a result, proposed system has a lower cost and higher e efficiency. This paper presents th$\varepsilon$ design and anlaysis of the propoSlU ballast and some 앉아、nmental results.

  • PDF

Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System (HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로)

  • Jung, Jae-Hun;Cho, Han-Je;Goo, Beob-Jin;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.