• Title/Summary/Keyword: Auxiliary power supply

Search Result 167, Processing Time 0.024 seconds

High Reliability Proto-type Auxiliary Power Supply Development for Satellite (위성용 고 신뢰성 Proto-type 보조전원 공급기 개발)

  • Choo, Won-Gyo;Kim, Hyun-Gu;Woo, Hyung-Je;Koo, Ja-Chun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.94-98
    • /
    • 2010
  • The auxiliary power supply for satellite should make the power safe and support it for subsystems during its operational lifetime. Several contstraints should be required to get high reliability. In this paper, the auxiliary power supply was satisifed and designed to be satisified with some contstraints. Control circuits for the auxiliary power supply used majority voter circuits to remove the single point failure. To verify majority voter circuits, proto-type auxiliary power supply was manufactured and tested.

A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method (최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구)

  • Choe, Gyu-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF

A study on the converter of auxiliary power supply for electric railway vehicles (전기 철도차량용 보조전원장치의 컨버터에 관한 연구)

  • Kim, Jae-Moon;Kim, Yang-Soo;Lee, Jong-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.467-468
    • /
    • 2007
  • This paper describes characteristics of converters of auxiliary power supply for electric railway vehicles. Auxiliary power supply is called Static Inverter(SIV) which supplied lamps, air conditioning and heat equipments, control systems, etc. Simulation results shows that line No.1 cheon contains low harmonics compared with those of KTX.

  • PDF

Design of an Auxiliary Switching Power Supply (보조 전환력 공급의 설계)

  • Luo, Yixiao;Chen, Dezhi;Kwon, Byung-il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1022-1024
    • /
    • 2015
  • An auxiliary switching power supply is designed for the control circuit of a machine integrated with frequency variation based on TOP249Y in this paper. And experiments have been conducted to verify that this power supply can function well even with fluctuating inputs, indicating the validity of this switching power supply and it can be applied to supply some other electrical equipments.

  • PDF

A Study on Noise Reduction for Auxiliary Power Supply of railway Vehicle Using IGBT (IGBT를 이용한 전동차용 보조전원장치의 소음 저감에 관한 연구)

  • 노애숙;김주범;배기훈;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.280-286
    • /
    • 1998
  • In recent years, the interest in noise increases gradually and the low noise level becomes one of the important performances in electrical equipment for railway vehicle. In the auxiliary power supply, most of the noise is made by the current ripple of alternating current reactor(ACL) which filters the output voltage. And this current ripple results from the voltage harmonics across the ACL. So the noise can be reduced by eliminating the voltage harmonics across the ACL. This paper shows harmonic eliminating technique which is making gating signals of upper and lower inverter have a phase difference in the 12-step inverter type auxiliary power supply. This technique was proved by testing on the developed 180KVA auxiliary power supply using IGBT.

  • PDF

Development of Auxiliary Power Supply for Industrial Magnetron (산업용 마그네트론 보조전원 개발)

  • Ryoo, H.J.;Kim, J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.47-49
    • /
    • 2007
  • For the magnetron, two kinds of auxiliary power is required to generate proper heat and electromagnetic field. In this paper the development of filament power supply and magnet power supply for high power industrial magnetron is studied. The filament power supply which is generate proper heat, even it doesn't require high power like main power supplies, has many consideration such as high voltage insulation and power control coordinated with high voltage cathod current to maintain constant heat generation. The novel control method using constant resistance control is proposed for accurate control of filament power supply.

  • PDF

A Study on the Failure code of the MVB Protocol when the Electric locomotive(8200 series) New Auxiliary Power Supply is applied (전기기관차(8200호대) 신규 보조전원장치 적용 시 MVB 통신프로토콜 중 고장코드에 관한 연구)

  • Bae, Young-Kyu;Shin, Hwa-Song;Jeong, Hwi-Seob;Son, Ki-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.2
    • /
    • pp.377-382
    • /
    • 2018
  • In order to partially localize the electric locomotive(8200 series) currently being operated, analysis of the inter-device MVB protocol in the electric locomotive should be performed first. Especially, it is necessary to analyze the operation when a newly developed auxiliary power supply is applied. In this paper, when a new auxiliary power supply applied to a conventional electric locomotive through a newly developed communication control unit using the analyzed protocol, a protocol for a failure codes was analyzed.

A Development of the High Performance IGBT type Auxiliary Power Supply for Railways. (전동차용 고성능 IGBT형 보조전원장치 개발)

  • 김태완;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • This paper presents the h밍h performance [GBT type auxiliary jXlWer supply designt.'Cl by new concept. For t the simplification and higher performance, the direct :3 level PWlVl inverter using the high capacity IGBT and t the 32bit DSP are adopted. The cost as well as bulk and weight is appreciably reduced about 40% lower than t those of conventional one. the electrical efficiency above 94~) o and the audible noise level is less than 65dB. In a addition, the TIID(Total lIannonic Distortion) factor is below 5% an이 the voltage fluctuation on a transient s state is below 10%.w 10%.

  • PDF

Auxiliary Power Supply using Photovoltaic Power Generation for Air-Conditioner (태양광발전을 이용한 에어콘의 보조운전 제어 시스템)

  • 황인호;유권종;송진수;이후기;정찬규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.47-52
    • /
    • 1993
  • Recently, as exactly clean source, the research of photovoltaic power generation is undertaken actively and widely. In this paper, an auxiliary power supply system which is composed of photovoltaic generation and DC-DC boost chopper is described. This system in mainly for Air-conditioner appliances is which AC source is formed through rectifying circuit and without electrical storage battery. There exist two operating modes depending on the power quantity of the solar cells and the load. The control algorithm is discussed.

  • PDF