• Title/Summary/Keyword: Auto-Calibration

Search Result 119, Processing Time 0.025 seconds

PRINCIPAL COMPONENTS BASED SUPPORT VECTOR REGRESSION MODEL FOR ON-LINE INSTRUMENT CALIBRATION MONITORING IN NPPS

  • Seo, In-Yong;Ha, Bok-Nam;Lee, Sung-Woo;Shin, Chang-Hoon;Kim, Seong-Jun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.219-230
    • /
    • 2010
  • In nuclear power plants (NPPs), periodic sensor calibrations are required to assure that sensors are operating correctly. By checking the sensor's operating status at every fuel outage, faulty sensors may remain undetected for periods of up to 24 months. Moreover, typically, only a few faulty sensors are found to be calibrated. For the safe operation of NPP and the reduction of unnecessary calibration, on-line instrument calibration monitoring is needed. In this study, principal component-based auto-associative support vector regression (PCSVR) using response surface methodology (RSM) is proposed for the sensor signal validation of NPPs. This paper describes the design of a PCSVR-based sensor validation system for a power generation system. RSM is employed to determine the optimal values of SVR hyperparameters and is compared to the genetic algorithm (GA). The proposed PCSVR model is confirmed with the actual plant data of Kori Nuclear Power Plant Unit 3 and is compared with the Auto-Associative support vector regression (AASVR) and the auto-associative neural network (AANN) model. The auto-sensitivity of AASVR is improved by around six times by using a PCA, resulting in good detection of sensor drift. Compared to AANN, accuracy and cross-sensitivity are better while the auto-sensitivity is almost the same. Meanwhile, the proposed RSM for the optimization of the PCSVR algorithm performs even better in terms of accuracy, auto-sensitivity, and averaged maximum error, except in averaged RMS error, and this method is much more time efficient compared to the conventional GA method.

Calibration of index tables using electric comparators (전기 마이크로미터를 이용한 회전 눈금원판의 교정)

  • Nam, Ki-Chul;Woo, In-Hun;Kim, Jong-Su;Lim, Jae-Sun;Chung, Myung-Se
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.4
    • /
    • pp.36-42
    • /
    • 1987
  • Very accurate calibration is needed to index tables which are necessary for precision angle measurement. The repeatability of index table is less than 0.2 second, so that attentions should be paid to choosing devices to be used in the calibration of index tables. The auto- collimators have been used in the calibration of index tables, but the repeatability of auto- collimators is bad compared with that of index table. In place of autocollimators, we described a method which uses electric comparators which are possessed by most precision measurement laboratories. Electric comparators are set to measure small angle displacement without interrupting the rotation of index tables and the signals of two electric comparators are added to remove the run-out errors of the shafts of index tables. Two index tables have been calibrated simulataneously by this method and the measurement data have been analyzed by the least squares method. We compare the calibration results with those of methods using autocollimator and auto- matic autocollimator and are able to know that the data of electric comparator method lie between the data of autocollimator methods. The repeatability of measurement is less than 0.02 second. The electric comparator method is economical and capable of reducing the uncertainty of the measurement.

  • PDF

ENOB 8-bit / 49.98dB-SNDR SAR ADC with Auto Zero Calibration Technique for Offset Improvement (Offset 개선을 위해 Auto Zero Calibration 기법을 적용한 8-bit / 49.98dB-SNDR SAR ADC 설계)

  • Chae Eun Jung;Juwon Oh;Young-Gun Pu;Kang-Yoon Lee
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.3
    • /
    • pp.13-18
    • /
    • 2024
  • This paper proposes a circuit utilizing auto zero technology to minimize offset and enhance accuracy in the reference generator and comparator. As evidence, a comparison between pre and post auto zero usage revealed a reduction of approximately 90% in standard deviation. The proposed circuit was implemented using a 55nm CMOS process, with an input frequency of 781.2 Hz. It achieves an Effective Number of Bits (ENOB) of 8.01 bits and a Signal-to-Noise Distortion Ratio (SNDR) of 49.98 dB.

Auto-calibration for the SWAT Model Hydrological Parameters Using Multi-objective Optimization Method (다중목적 최적화기 법을 이용한 SWAT 모형 수분매개변수의 자동보정)

  • Kim, Hak-Kwan;Kang, Moon-Seong;Park, Seung-Woo;Choi, Ji-Yong;Yang, Hee-Jeong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • The objective of this paper was to evaluate the auto-calibration with multi-objective optimization method to calibrate the parameters of the Soil and Water Assessment Tool (SWAT) model. The model was calibrated and validated by using nine years (1996-2004) of measured data for the 384-ha Baran reservoir subwatershed located in central Korea. Multi-objective optimization was performed for sixteen parameters related to runoff. The parameters were modified by the replacement or addition of an absolute change. The root mean square error (RMSE), relative mean absolute error (RMAE), Nash-Sutcliffe efficiency index (EI), determination coefficient ($R^2$) were used to evaluate the results of calibration and validation. The statistics of RMSE, RMAE, EI, and $R^2$ were 4.66 mm/day, 0.53 mm/day 0.86, and 0.89 for the calibration period and 3.98 mm/day, 0.51 mm/day, 0.83, and 0.84 for the validation period respectively. The statistical parameters indicated that the model provided a reasonable estimation of the runoff at the study watershed. This result was illustrated with a multi-objective optimization for the flow at an observation site within the Baran reservoir watershed.

Development of Auto-calibration System for Micro-Simulation Model using Aggregated Data (Case Study of Urban Express) (집계자료를 이용한 미시적 시뮬레이션 모형의 자동정산체계 개발 (도시고속도로사례))

  • Lee, Ho-Sang;Lee, Tae-Gyeong;Ma, Guk-Jun;Kim, Yeong-Chan;Won, Je-Mu
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.1
    • /
    • pp.113-123
    • /
    • 2011
  • The application of micro-simulation model has been extended farther with improvement of computer performance and development of complicated model. To make a micro-simulation model accurately replicate field traffic conditions, model calibration is very crucial. Studies on calibration of micro-simulation model have not been enough while lots of studies on calibration of macro-simulation model have been continued in our country. This paper presents an auto-calibration of parameter values in micro-simulation model(VISSIM) using genetic algorithm. RMSE(Root Mean Square Error) of collected volume on the urban expressway versus simulated volume is set as MOP(measure of performance) and objective function of optimization is set as to minimize the RMSE. Applying to urban expressway(Nae-bu circular) as a case study, it shows that RMSE of optimized parameter values decrease 60.4%($19.3{\longrightarrow}7.6$) compared to default parameter values and the proposed auto-calibration system is very effective.

Semi-Auto Camera Calibration Method for 3D Information Generation (3차원 공간정보 생성을 위한 반자동 카메라 교정 방법)

  • Kim, Hyungtae;Paik, Joonki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.127-135
    • /
    • 2015
  • In this paper, we propose the semi-auto camera calibration method including user input. The proposed method estimates the vanishing points using user defined reference lines and defines the constraint for reducing outlier in vanishing points estimation process. The proposed camera calibration method based on both algebraic and geometric method improves a calibration performance for difficult condition, which represents that existing method can't calibrate a image. Experimental results show that the proposed method calibration accuracy higher than existing method.

3D Reconstruction using the Key-frame Selection from Reprojection Error (카메라 재투영 오차로부터 중요영상 선택을 이용한 3차원 재구성)

  • Seo, Yung-Ho;Kim, Sang-Hoon;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.38-46
    • /
    • 2008
  • Key-frame selection algorithm is defined as the process of selecting a necessary images for 3D reconstruction from the uncalibrated images. Also, camera calibration of images is necessary for 3D reconstuction. In this paper, we propose a new method of Key-frame selection with the minimal error for camera calibration. Using the full-auto-calibration, we estimate camera parameters for all selected Key-frames. We remove the false matching using the fundamental matrix computed by algebraic deviation from the estimated camera parameters. Finally we obtain 3D reconstructed data. Our experimental results show that the proposed approach is required rather lower time costs than others, the error of reconstructed data is the smallest. The elapsed time for estimating the fundamental matrix is very fast and the error of estimated fundamental matrix is similar to others.

Development of Automatic Calibration System for PC-Based Pure Tone Audiometer (PC 기반 순음청력검사기를 위한 자동보정시스템 개발)

  • Kim, Jin-Dong;Kang, Deok-Hun;Song, Bok-Deuk;Lee, Il-Woo;Kong, Soo-Keun;Kwon, Soon-Bok;Jeon, Gye-Rok;Shin, Bum-Joo;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2586-2594
    • /
    • 2010
  • A pure tone audiometer should be able to produce both pure tone and masking noise with exact sound pressure level and frequency. For such purpose, it is unavoidable to periodically calibrates pure tone audiometer. However, manual acoustic calibration requires not only attention but also long time. It is possible to execute automatically calibration using software if it is PC-based pure tone audiometer. In this paper, we describe auto-calibration software for PC-based pure tone audiometer and dedicated sound level meter which has been implemented upon PC by us. To verify auto-calibration module, we examine whether output of PC-based audiometer calibrated through auto-calibration of this paper satisfies RETSPL of IEC or not.

Camera Motion and Structure Recovery Using Two-step Sampling (2단계 샘플링을 이용한 카메라 움직임 및 장면 구조 복원)

  • 서정국;조청운;홍현기
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.347-356
    • /
    • 2003
  • Camera pose and scene geometry estimation from video sequences is widely used in various areas such as image composition. Structure and motion recovery based on the auto calibration algorithm can insert synthetic 3D objects in real but un modeled scenes and create their views from the camera positions. However, most previous methods require bundle adjustment or non linear minimization process [or more precise results. This paper presents a new auto' calibration algorithm for video sequence based on two steps: the one is key frame selection, and the other removes the key frame with inaccurate camera matrix based on an absolute quadric estimation by LMedS. In the experimental results, we have demonstrated that the proposed method can achieve a precise camera pose estimation and scene geometry recovery without bundle adjustment. In addition, virtual objects have been inserted in the real images by using the camera trajectories.

A Simple Auto Calibration Method for CCD Camera With High Distortion Lens (왜곡율이 큰 렌즈가 부착된 CCD 카메라를 위한 간단한 자동 보정 방법)

  • 한기태;김회율
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.260-272
    • /
    • 2000
  • In this paper, we propose a simple auto calibration method for a CCD camera with wide an91e lens that causes high degree of distortion. We formulate a cubic warping equation for the relationship between the cross points on the distorted calibration target and the corresponding points from the standard grid image, and calibrate distorted images using the computed parameters. The experiment has been performed with the distorted images resulted from wide angle CCD camera. The experimental results show that the proposed method, in terms of the average and maximum distorted error, has higher accuracy than the existing methods because of maintaining the calibration ratio more than 95 percent. The proposed method is applicable to wide variety of images regardless a type of lens or distortion.

  • PDF