• Title/Summary/Keyword: Area Standard

Search Result 4,517, Processing Time 0.046 seconds

A Comparative Research on the Facility Criteria of Cities·Provinces Education Office and Space Program of Competition School in Chung-buk Province (시·도 교육청별 중·고등학교의 시설기준과 충북지역 현상설계 학교의 스페이스프로그램 비교 연구)

  • Chang, Dong-Hoon;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.3
    • /
    • pp.3-11
    • /
    • 2015
  • Under the establishment and operating regulations of school presented only minimum standard for the founding of the school. Therefore, It is intended to suggest the reasonable space standard of the school facility, through comparison & analysis of facility standard in each city and provincial education office. Especially, The facilities standard of Chungcheongbuk-do Office Of Education has been exceeded standardization of architectural space which is proposed the Ministry of Education, and they has made the various learning space reflected creative ideas by designing all of the new school competition since 2000. In order to deal with reacting the changing method of studying like as the examples of Middle & High school in Chungcheongbuk-do, they need to set aside the enough required area for a head of students and the common space which is more than 40% in the total area according to the various learning space, securing the supporting facilities, and break & movement of the students. Moreover, Each of the city and provincial education offices are needed to establish the standardization of proper area for space organization of the planned school throughout upcoming competition.

Evaluation of the Residual Performance of Partially Charred Components of Old Wooden Structure I - Use of Ultrasonic Velocity and Testing of the Drilling Resistance -

  • Lee, Hyun-Mi;Hwang, Won-Joung;Lee, Dong-Heub;Kim, Hong Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.193-206
    • /
    • 2014
  • Residual performance of old architectural wood which has been damaged was measured using Nondestructive Evaluation (NDE). The wood Pole Tester was used to assess ultrasonic velocity inside wood and drill resistance was determined using an IML-resistograph. For ultrasonic measurements squared timber and circular timber's measurements were separately conducted with 1,300 m/s as the standard ultrasonic velocity. The standard wood samples divided into two parts; a non-sound area (below the standard), and a sound area (above the standard). Furthermore, schematization of wood was compared with results naked eye observation. The drilling resistance test was performed for both length and thickness direction in wood. The internal of the drilling was set at 30 cm (length direction), 5 cm (width direction) and 30cm (thickness direction). A non-sound area was defined as that 1) amplitude is below 20% and 2) carbonization and deterioration are related.

A Study on Proposal of the Refuge Area Standard in Super-High-Rise Building Fire (초고층 건축물 화재시 피난공간 기준 제안에 관한 연구)

  • Park, Sang-Gyu;Roh, Sam-Kew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.76-79
    • /
    • 2008
  • This thesis analyzed the evacuation problem when fire breaks out in the super-high-rise buildings and proposed the refuge areas as a method of seeking for the residents' safety and considered its necessity. And drew out the factors which should be considered to prepare refuge area standard, and demonstrated those drawn factors for solution one by one and then proposed as the refuge standard.

  • PDF

Improvement of the Standard Cost of Development Charge System in Jeju (개발부담금제도에 따른 제주지역의 표준비용 산정 개선방안)

  • Hong, Seung-Jong;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.1421-1429
    • /
    • 2015
  • During the six years from 2006 to 2011, based on a study of projects with an area equivalent to or less than $2,700m^2$ located in Jeju self-governing province, it was shown, through comparison with the pre-existing calculation methods, that there were many problems with the application of the standard cost. Accounting for the uniqueness of Jeju province, the study suggested an alternative method for applying the standard cost, basing it on property usage of either urban area or non-urban area pursuant to the National Land Planning and Utilization Act rather than land type of either mountain area or non-mountain area, with the utilization of T-test and ANOVA raising the reliability of this study.

Evaluation of Raingauge Density and Spatial Distribution: A Case Study for Nam Han River Basin (우량계의 밀도 및 공간분포 검토: 남한강 유역을 중심으로)

  • Yoo, Chul-Sang;Kim, In-Bae;Ryoo, So-Ra
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.2
    • /
    • pp.173-181
    • /
    • 2003
  • This study has evaluated the raingauge network of Nam-Han River Basin by assuming that the rainfall field is homogeneous in space and its spatial correlation structure is exponential. The results of the study was compared with the standard of WMO. Summarizing the results are as follows: (1) The Nam-Han River Basin is not the mountain area, nor the plain area of the WMO standard. However, the correlation length of the downstream part is longer than that of the upstream part, enough to differentiate the rainfall fields in both areas. (2) It seems that the standard for the evaluation of the raingauge network of Nam-Han River Basin should be decided to represent upper 50% of correlations derived, when the maximum intervals between neighboring gauges are estimated to be 18.2km for the upstream area and 21.1km for the downstream area. Simply evaluating the raingauge density, the Nam-Han River Basin has enough raingauges exceeding the WMO standard for the mountain area in the temperate region. (3) Evaluation of the spatial distribution of raingauges in the Nam-Han River Basin shows that its spatial distribution Is not in a proper level, especially when applying the WMO standard for the mountain area in the temperate region. However, when applying the new standard proposed in this study, only five to six more raingauges are required to be added.

A Study to Determine of Acceptable Noise Regulations on Roadside Noise Abatement (도로변 방음대책 수립시 합리적인 소음규정 적용에 대한 연구)

  • Son, Jung-Gon;Kim, Jeung-Tae;Jo, Yun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.550-555
    • /
    • 2011
  • The road traffic noise has emerged major noise as the overcrowding of the urban population and the explosion of car storage capacity. There are limits for establishing the measures to meet noise standard because of the increase of high-rise building and insufficient distance between residential areas and road in urban center areas. Therefore, this study analyze the problem of the application of national road noise standard, and present the alternatives to achieve environmental standards in conjunction with the soundproofing measures. To reduce the population ratio exposed to road noise on seoul motorway, we suggest some action plane are as follows: i) Roadside noise standard of nighttime beside daytime is the first noise reduction goals ii) Noise standard of Noise and vibration control act is priority in case of existing area iii) Noise standard of basic environmental policy act is priority in case of new area.

  • PDF

Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles (토목 발파가 소음, 진동, 부유 분진에 미치는 영향)

  • Jeong, Jin Do;Jeong, Yeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

A Study on the Status of Illumination Environment in Workplaces (업무공간의 조명 환경 실태 조사 연구)

  • Choi Han-Hee;Ha Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.6
    • /
    • pp.167-174
    • /
    • 2004
  • The purpose of this study is to examinethe present illumination conditions in office environment and to suggest an efficient illumination plan in office planning process. Illumination conditions in work environment were surveyed in 6 offices to investigate whether the present illumination conditions were appropriate to the work type. The results of this study are as follows: Most of the general Illuminance level in the area of work were all at an adequate level, except one. The average Illuminance level in the all meeting rooms were met for the standard. Illuminance in the all reception area were extremely over the standard, The illuminations of this area were rather designed according to the image of the company than the standard. As for the illumination method in the area of general work, four offices used a general lighting by a direct lighting type, while two offices used a general lighting and a task lighting at the same time. This survey suggested that first, each company should consider illumination plan in the building planning process, second, illumination plan considering the type of places is needed, and third, illumination environment may be differentiated according to the work type. In conclusion, efficient illumination environment should be considered in office building planning process, especially In terms of illumination materials and methods.

A Study on the Maneuvering Area of Ship in Moving at Single Point Mooring (SPM 이안 선박의 조종영역에 관한 연구)

  • Kim, Jin-Soo
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.23
    • /
    • pp.78-97
    • /
    • 2007
  • SPM, which is an abbreviation of Single Point Mooring, also called as SBM(Single Buoy Mooring), is a special buoy besides the quays of the harbor for mooring ships, and is normally a 3m wide cone or cylinder shaped steel drum fixed underwater so it won't move, and is used for mooring cargo-work at outer port by laid-up ships and large crude oil carrier. The work of VLCC SPM mainly is accomplished on the open sea. On the open sea as a result of meteorological condition and the ocean wave influence, When the weather condition is get bed, peremptorily moving to the safety place, because of the gale and the billow, almost happened frequently, the pilot is unable to go on board and the tug is also unable to be used Now because of the bad weather the VLCC SPM moving to the other safety place frequently happened in the ulsan port. the construction of new harbor, it constructed many break water around SPM. So that it is necessary to propose the new standard about how to maneuvering area actually. The standard for handling ranges of the SPM operations was tested and verified by a simulation.. So that it is necessary to propose the new standard about how to maneuvering area actually.

  • PDF

An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings (건축물의 중수도 설치기준에 대한 제도적 개선방안)

  • Kong, Young Hyo
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.