• 제목/요약/키워드: Area Replacement Ratio

검색결과 114건 처리시간 0.032초

쇄석말뚝의 지지력 특성에 관한 모형시험 연구 (A Model Test Study on the Bearing Capacity of the Crushed Stone Pile)

  • 이상익;박용원;김병일;윤길림
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.299-306
    • /
    • 2001
  • Crushed Stone Pile(CSP) is one of the ground improvement methods available to loose sand and clayey ground by forming compacted CSP in the weak soil layer. The effects of this method are enhancement of ground bearing capacity, reduction of settlement and prevention of lateral ground movement in cohesive layer, reduction of liquefaction potential in sandy ground. This study performs model tests in 1.0m${\times}$1.0m${\times}$1.0m and 1.5m${\times}$1.5m${\times}$l.2m model tank to observe bearing capacity of CSP treated ground. The area replacement ratio of CSP composite ground varies 20%, 30% and 40% with square grid pattern. After the composite ground was consolidated under pressure of 0.5kg/$\textrm{cm}^2$ and 1.0kg/$\textrm{cm}^2$, load tests were carried out. The results show that ultimate bearing capacity increases with area replacement ratio and the preconsolidation pressure of ground.

  • PDF

연/강성 하중을 받는 복합지반의 응력분담거동에 대한 원심모형시험 (Centrifugal Model Test on Stress Concentration Behaviors of Composition Ground under Flexible/Stiff Surcharge Loadings)

  • 송명근;배우석;안상로;허열
    • 한국지반환경공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.5-15
    • /
    • 2011
  • 본 연구에서는 조립질 말뚝으로 개량된 점토지반의 응력변화 및 응력분담비의 변화를 파악하기 위하여 말뚝의 종류(GCP, SCP)와 하중재하조건, 치환율을 변화시키면서 원심모형실험을 수행하였다. 강성재하실험 결과, 동일 치환율에서 점토지반에서의 연직응력은 유사한 반면, 말뚝상부에서의 연직응력은 GCP로 보강한 경우가 SCP보다 크게 나타났다. 또한, GCP 및 SCP의 치환율이 증가할수록 평균 응력분담비가 거의 비례적으로 증가하였고, GCP로 개량된 경우 평균 응력분담비가 SCP로 개량된 지반에 비해 크게 평가되었다. 또한 연성재하 실험결과 쇄석다짐말뚝 및 모래다짐말뚝의 치환율이 40%인 경우가 가장 큰 응력분담비를 나타내었으며, GCP로 개량된 경우의 평균 응력분담비가 SCP를 설치한 경우보다 약간 크게 나타났다.

기초분리말뚝 공법의 설계기법 개발 (Development of Design Method of Disconnected Piled Raft Foundation System)

  • 최정인;민기훈;김성호;권오성;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.691-699
    • /
    • 2008
  • In the design of a foundation, settlement of the foundation may exceed allowable design criteria even with a competent bearing stratum. In such a case, a piled-raft foundation system may be adopted using piles as settlement reducing component. In this paper, Disconnected Piled Raft Foundation (DPRF) system, which installs disconnected piles underneath the raft and uses the piles as ground reinforcements, is studied as a cost effective design method against the classical piled-raft foundation system. To this end, large size loading tests were carried out on weathered ground changing area replacement ratio and length of piles. The results indicated that the settlement of the reinforced ground was reduced by 34~87% and the allowable bearing pressure increased by 70% on average from those of the unreinforced original ground, respectively. The correlating formula between the area replacement ratio and the load bearing ratio of piles were derived from the test results and numerical analysis. From the correlation, a design method determining the size and the quantity of the disconnected piles to enhance the bearing capacity of original ground to the desired value was proposed based on one inch settlement criteria.

  • PDF

모래다짐말뚝으로 개량된 복합지반의 거동에 관한 원심모형실험 - 응력집중을 중심으로 - (Centrifugal Model Test on the Behaviors of Composite Ground Improved with Sand Compaction Piles - Focused on Stress Concentration of SCPs -)

  • 배우석;오세욱;신방웅
    • 대한토목학회논문집
    • /
    • 제26권1C호
    • /
    • pp.19-24
    • /
    • 2006
  • 본 연구에서는 저치환율의 모래다짐말뚝으로 개량된 복합지반에서 SCP와 주변지반 사이의 응력 분담 효과를 평가하기 위하여 원심모형시험을 수행하였다. 모래다짐말뚝은 동결법에 의해 형성하였으며, 응력분담거동을 관찰하기 위하여 말뚝과 주변점토지반에 압력계를 설치하였다. 원심모형실험결과, 응력집중비는 주로 하중조건과 면적치환비 그리고 경과시간에 따라 영향을 받는 것으로 나타났다.

실내시험을 이용한 저치환 보강지반의 평가 (Evaluation of the Low Replacement Reinforced Ground Using Laboratory Tests)

  • 배우석
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.131-137
    • /
    • 2008
  • SCP(Sand Compaction Pile) method that forms a composite ground by driving compacted sand piles into the soft ground. This method is one of the soil improvement techniques for reinforcing and strengthening soft ground deposits. This thesis describes the investigation on the behavior of soft ground reinforced with SCP by low improvement ratio. Direct shear test and consolidation test carried out to verified behavior of composite ground reinforced with SCP. Test results were discussed with reference to the amount of consolidation settlement, variation of shear resistance with area replacement ratio and effect of the stress concentration. And, laboratory model loading test carried out to verified the effect of the location and failure mode of reinforced embankment. Residual shear strength varies with the area replacement and constrict load in the low replacement ratio. Calculated stress concentration ratio overestimate than proposed valve by experimental, theoretical and analytical method. As regards the location, improving right below of the top of the slope was more effective than below of the toe of the slope. This thesis carried out to obtain fundamental information of behavior of the composit ground. Hereafter, centrifuge test that reproduce stress state of the in-situ must be necessary through the further study about pile penetration, reinforce position and construct time.

고로슬래그 미분말을 사용한 콘크리트의 방청성능에 관한 연구 (A Study on the Rust-protection Performance of Concrete using Ground Granulated Blast-furnace Slag)

  • 박상준;김동석;원철;이상수;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 2001
  • In this paper, rust-protection performance of concrete using ground granulated blast-furnace slag are discussed. 4 kinds of W/B in combination with 3 kinds of replacement ratio of ground granulated blast-furnace slag and 2 kinds of chloride ion contents of are selected as experimental parameters. According to the experimental results, as the replacement ratio of ground granulated blast-furnace slag is increased, the corrosion area of steel bar tends to be decreased. However, as the autoclave cycle and chloride ion contents are increased, the corrosion area of steel bar is increased. In conclusion, when the replacement ratio of ground granulated blast-furnace slag is 50%, the strength and rust-protection performance appear to be most excellent.

  • PDF

폐콘크리트 분말의 분말도가 모르타르의 품질특성에 미치는 영향 (The Effect on the Quality Properties of Mortar by Surface Area of Waste Concrete Powder)

  • 최연왕;문대중;김성수;정재권;김용직
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.365-368
    • /
    • 2005
  • Waste concrete powder(WCP) has been estimated with a great value-added material as by-product of waste concrete manufactured to fine and coarse aggregate for concrete, because it is able to utilized for cement clinker and concrete admixture. Experimental tests were performed as such plastic viscosity of paste, flow and compressive strength of mortar by surface area of WCP. As a result, flow and 28days compressive strength of mortar was decreased according to increased replacement ratio of WCP as compared to control mortar. Also, plastic viscosity of paste used WCP1 and WCP2 was decreased with increasing replacement ratio, but WCP3 was increased with increasing replacement ratio.

  • PDF

대형토조시험을 이용한 모래다짐말뚝이 적용된 복합지반의 침하 및 하중전이특성 (The Characteristics of the Composite Ground with Sand Compaction Pile(SCP) using Large Soil Box)

  • 김우석;박언상;김재권;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.974-981
    • /
    • 2005
  • Because general laboratory tests for sand compaction pile method including unit-cell test device have fixed outside diameter, as area replacement ratio increase, diameter of sand pile increase. These condition can bring about overestimation of stiffness of composite ground. In addition, existing large soil box which consist of bellows type loading plate can occur serious mistake in checking the amount of drained water because there are additional drainage along the inside wall in device. Overcoming these shortcoming, this paper developed modified large scale soil box consist of piston type load plate. In this study, using this device, series of modified large scale soil box tests were performed, and investigated the settlement and stress transportation characteristics with area replacement ratio in sand compaction pile method.

  • PDF

저치환율 SCP에 의한 복합지반의 압밀 과정중에 발생하는 응력분담거동과 그 메커니즘 (Stress Sharing Behaviors and its Mechanism During Consolidation Process of Composition Ground Improved by Sand Compaction Piles with Low Replacement Area Ratio)

  • 유승경
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.301-310
    • /
    • 2003
  • 저치환율 샌드콤팩션파일공법(SCP공법)을 합리적으로 설계하기 위해서는 압밀중에 발생하는 복합지반 내부의 모래말뚝과 점토 양자의 상호역학거동을 정확히 파악하고 그 메커니즘을 이해하여야 할 필요성이 있다. 본 논문에서는 저치환율 SCP공법에 의해 개량된 복합지반의 압밀중에 발생하는 역학적 상호작용을 규명하기 위하여 일련의 수치해석을 실시하였다. 수치해석은 탄점소성 압밀 유한요소법을 적용하였으며, 그에 대한 신뢰성은 SCP에 의해 개량된 복합지반의 압밀거동에 대한 일련의 모형실험 결과와의 비교를 통해 검증할 수 있었다. 또한, 수치해석의 결과들로부터 저치환율의 모래말뚝이 타설된 복합지반의 모래말뚝과 점토에 대해 압밀중에 발생되는 각각의 역학거동과 복합지반 내부에 대한 응력분담 메커니즘에 대하여 규명하였다.

GCP로 개량된 복합지반의 관통률에 따른 응력분담비 (Stress Concentration Ratio According to Penetration Rate of Composite Ground Reinforced with GCP)

  • 나승주;김대현;이익효;이강일
    • 한국지반신소재학회논문집
    • /
    • 제16권2호
    • /
    • pp.35-45
    • /
    • 2017
  • 쇄석다짐말뚝(GCP)은 연약지반의 지지력 증가와 침하량 감소를 실현할 수 있어 연약지반 개량에 활발하게 사용되고 있다. 그리고 GCP 설계에 필요한 응력분담비는 치환율, 상재하중, 깊이, 관통률 등에 따라 달라진다. 그동안 많은 연구자들이 현장 실내 실험, 수치해석 연구를 통해 GCP로 개량된 복합지반의 응력분담비를 제안하였지만 명확하게 제시되지 못한 실정이다. 본 연구에서는 GCP공법의 합리적인 설계법 제안을 위한 기초연구로써, 유한요소해석프로그램인 ABAQUS 6.12-4를 이용하여 GCP로 개량된 복합지반을 모델링하여 치환율과 관통률에 따른 침하량과 응력분담비를 분석하고자 하였다, 그 결과, 최상부 지점을 제외한 다른 지점에서의 응력분담비의 값은 관통률 60%일 때 1.21~5.36, 관통률 80%일 때 1.19~5.45, 관통률 100%일 때 2.16~5.60 이었다. 이는 관통률과 치환율이 증가할수록 응력분담비의 값은 크게 증가함을 알 수 있다.