• Title/Summary/Keyword: Apparent Discharge

Search Result 64, Processing Time 0.023 seconds

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

UHF Sensor Location Optimization for Partial Discharge Signals Detection Method (UHF 센서 위치 최적화로 부분방전 신호 검출 방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.409-413
    • /
    • 2014
  • GIS partial discharge that occurred in the UHF band signal is effectively detected by the method to IEC60270 5pc the apparent minimum discharge can be detected over the GIS arrangement of the sensor interior and exterior of the UHF in accordance with the optimized position signal by considering the damping ratio is selected so that the signals can be obtained to be mounted. 362kV, 800kV GIS is installed on the internal and external sensors are UHF band signal attenuation is set by measuring the reference value, but the operation, 170kV case 362kV, 800kV on the basis of the measurement data and to be installed and operated. When 170kV per 1Bay by installing the built-in sensor 1 for detecting a partial discharge signal, But, GIS signal attenuation is large in the case of an internal partial discharge signal is not detected in some cases. Where the attenuation is great UHF signal of the sensor by increasing the quantity of partial discharge signals were acquired to allow relocation. The greater the spacing between the sensor and the sensor is applied simplifies the installation and reduces the cost in terms of maintenance of appropriate optimal position is calculated to detect the partial discharge signal is needed. Thus 170kV GIS signal power attenuation of a partial discharge by measuring the UHF sensor, and by relocating the proper position is calculated in accordance with the sensor signal decay rate and minimize the error of omission in detecting a partial discharge signal was optimized.

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

Improvement of Printing Properties of PET Micro Filament Fabrics Using Low Temperature Plasma Technology(I) (저온 plasma 기술에 의한 PET 극세사직물의 날염성 개선(I))

  • 조규민;이종훈
    • Textile Coloration and Finishing
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 1995
  • In order to improve dyeability of poly(ethylene terephthalate)(PET) micro filament fabrics, the effect of the prior oxygen low temperature plasma on the subsequent dyeing(deep dyeing, printing) was examined in various conditions. The apparent concentration of dyed PET micro filament fabrics was increased by $O_{2}$plasma treatment. Higher discharge power levels and higher reactor pressure values created more significant effect. The wettability was significantly increased by $O_{2}$ plasma treatment. Therefore, it is predicted that introducing hydrophilic group on the surface of material can improve the apparent concentration of PET micro filament fabrics.

  • PDF

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

CFCs 조사를 위한 지하수 시료채취방법 비교 및 평가

  • 고동찬;이대하;성현정;강철희;고경석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.21-23
    • /
    • 2002
  • Two sampling methods for chlorofluorocarbons(CFCs) in groundwater were compared and assessed with groundwater samples in Jeju Island. CFCs concentrations from copper tube method were widely variable among triplicates and higher than those from flame-sealed glass ampule method. For the copper tube method, this is aggravated by rubber packings in the faucet of discharge line of wells, which was removed for the glass ampule method. The poor reproducibility and apparent contamination of results by copper tube method is due to the improper sealing of copper tubes and materials in water discharge line. This suggests that it is more difficult to achieve complete isolation from the atmosphere in the copper tube method and that materials that could release CFCs should be avoided along the sampling flow lines. It seems that the flame-sealed glass ampule method is more relevant for groundwater sampling for CFCs though it requires more complicated equipments and procedures.

  • PDF

The study on the misfiring characteristics for the temperature variation (AC PDP의 온도 변화에 따른 오방전의 특성에 관한 연구)

  • Kim, Goon-Ho;Lee, Don-Kyu;Lee, Young-Kwon;Kim, Gyu-Seop;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.165-167
    • /
    • 2002
  • Stable reset and address discharge are very important when they show apparent display. But the shape of reset and address discharge and wall-charge distribution change, according to the variation on temperature. Namely, it is very difficult to show exact picture. This study represents how Dynamic Margin is height and dielectric thickness. When barrier rib height is $100{\mu}m$ and dielectirc thickness is $40{\mu}m$, it is responded the most sensitively by decreasing temperature.

  • PDF

Investigation of Changeable Discharge colour Controlled by Electronic Circuit (전자적 제어에 의한 가변색방전의 개발에 관한 연구)

  • 오철한;박덕규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.5
    • /
    • pp.164-169
    • /
    • 1983
  • A method to control the luminous colour of a gaseous discharge tube has been investigated by using the saw-tooth wave of which rise-time was controlled by an electronic circuit. The luminous colour of a Ne - Hg lamp was changed from red to blue continuously and vice versa, and it's luminous characteristics are as follows: (a) With D.C. potentials, it showed blue colour and the relative intensity of the colour is increased first and saturated at about 17 mA as the discharge current is increased. (b) When the rise-time of the saw-tooth wave is about 10 $\mu\textrm{s}$, the red colour which is caused by Ne - excitation is dominant, and when about 200 $\mu\textrm{s}$, only the blue colour which is caused by Hg - excitation is shown. (c) With saw-tooth pulse, the relative intensity of blue is increased similarly as that with D.C. potential as the current peak of each pulse is increased, while that of red is increasing continuously and it's intensity shows about twice than blue. (d) The spectrum of red colour contains Ne - excitation lines and Hg - blue lines, but the apparent luminous colour is red because Ne - red lines are more plenty than Hg-blue lines. The spectrum of blue colour presents only Hg-blre lines.

  • PDF

A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices (저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구)

  • Kil Gyung-Suk;Song Jae-Yong;Moon Seung-Bo;Cha Myung-Soo;Hwang Don-Ha;Kang Dong-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

Concordance Rate Between the Ratings of Clinician and Self Ratings of Worker on a Functional Capacity Evaluation

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.71-80
    • /
    • 2016
  • Background: Functional capacity evaluations (FCEs) are designed to systematically assess the capacity to perform work-related tasks and to determine worker's ability to return to the previous job following work-related injuries. These evaluations may be rated either by clinician or worker. There has been a lack of consensus between the two scoring methods. Objects: This study aimed: 1) to confirm if the data are fit to the Rasch rating scale model and 2) to investigate the item-level concordance rate between the ratings of clinician and injured worker of the FCE. Methods: A cross-sectional study was conducted with a sample (n=124) of a rehabilitation program with the Occupational Rehabilitation Data Base for workers with low back pain. The functional capacity evaluation at admission and discharge was administered to clinicians and workers. The data were analyzed using both classical test theory-based Pearson's r and intra-class coefficient followed by item-level analysis with Rasch rating scale model. Results: All items of the FCE, except sitting items rated by clinician at admission and handling items rated by both clinician and worker throughout admission and discharge, were acceptable fit statistics with minor out of ranges for a misfit criterion. This may indicate that the items of the FCE overall fit to the Rasch rating scale model. Few problematic items responding differently to clinician and worker both at admission and discharge were detected with the differential item functioning analysis despite the excellent concordance rate using the two conventional statistics-sitting and handling items at admission and handling item at discharge. Conclusion: The item-level speculations using Rasch analysis of the FCE demonstrate that the ratings of clinician and self ratings of worker were psychometrically acceptable though there was an apparent discrepancy between the raters both at admission and discharge.