무효전력 제어를 통한 새로운 독립운전 검출법 (A Novel Method for Anti-Islanding Using Reactive Power Control)

  • 정진범;최봉주;안강순;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

고조파 주입에 의한 계통연계형 태양광발전시스템의 고립운전 검출 (Islanding Detection by Harmonic Current Injection Method for Utility Interactive Photovoltaic System)

  • 고재석;채영민;강병희;최규하
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.199-210
    • /
    • 2003
  • 본 논문에서는 계통연계형 태양광발전시스템의 고립운전방지를 위한 새로운 고리운전 검출기법을 연구한다. 이를 위하여 계통연계형 태양광발전시스템 및 고립운전시의 특성에 대하여 기술하였다. 또한 고립운전의 검출특성을 향상시키기 위한 새로운 검출기법을 제시하고 해석하였으며 검출시험을 위한 부하조건 선정을 위한 부하임피던스 곡선을 해석적으로 유포하였다 ACSL 시뮬레이션 및 실험을 통하여 제시한 고립운전 검출기법 및 해석결과를 검증하였다.

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법 (Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load)

  • 오형민;최세완;김태희;이기풍;이태원
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

유효전력변동방식을 이용한 새로운 단독운전 검출기법 연구 (A Novel Active Anti-islanding Method using Effective Power Variation)

  • 유병규;정영석;미키히코 마츠이;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.213-215
    • /
    • 2006
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent the phenomenon, various anti-islanding methods have been studied. This paper proposes the variation method of inverter output current magnitude to prevent the islanding phenomenon as a novel method, which causes the large frequency variation of inverter output voltage after islanding. Unlike most active anti-islanding method deteriorating power quality, this novel method will have high performance of islanding detection and good power quality. For the verification of the proposed method, the simulated result and analyses are presented.

  • PDF

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.

PV-AF시스템에서 단독운전 방지기법 및 기존 단독운전 방지기법의 시뮬레이션 해석 및 비교 (A Simulation for Anti-islanding Method in PV-AF System and Existing Anti-islanding Method)

  • 김경훈;서효룡;이석주;박민원;유인근;전진홍;김슬기;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.206-207
    • /
    • 2007
  • Islanding is the electrical phenomenon in a part of a power network disconnected from the utility, where the loads are entirely supplied by PV systems, and where the voltage and frequency are maintained around nominal values. But islanding may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards[4]. Therefore, islanding must be detected and stopped. The existing anti-islanding methods have NDZ(None-detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, It is proved that PV-AF system has originally the function of anti-islanding without not only NDZ and but current distortion

  • PDF

계통연계형 태양광발전 인버터를 위한 주기적인 영전류 구간을 가지는 새로운 AFD 단독운전 검출기법 (Novel AFD method of islanding detection with a periodic zero current for improving on islanding detection for grid-connected Photovoltaic inverters)

  • 고문주;최익;최주엽;송승호;이기옥
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.17-23
    • /
    • 2006
  • This paper proposes a novel active frequency drift (AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. In this paper, injecting the periodic zero current into the basic AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 1547 with various load conditions. Detection of islanding is verified using simulation tool PSIM.

개선된 DFT을 이용한 무효전력변동 단독운전 검출기법의 성능 개선 (Performance Improvement of an Anti-Islanding Algorithm using the Variation of Reactive Power with an Improved DFT Method)

  • 강덕홍;최대근;이교범
    • 전력전자학회논문지
    • /
    • 제15권3호
    • /
    • pp.179-187
    • /
    • 2010
  • 본 논문에서는 무효전력변동기법을 사용하여 단독운전을 검출을 하기 위해서 선행되어야 하는 주파수 검출 방법 중에서 개선된 이산푸리에변환(Discrete Fourier Transform; DFT), 즉 Goertzel 알고리즘을 이용한 단독운전 검출기법을 제안한다. 실제 태양광 발전 시스템의 설치를 위해서는 전기사고나 시스템에 악영향을 유발하는 단독운전 검출기법의 연구가 선행되어야 한다. 적용하는 주파수 검출방법은 Goertzel 알고리즘을 이용한 기법으로 기존의 영점검출기법과 가상의 2상 PLL(Phase Locked Loop)에 비하여 외란의 영향에 강인하며 빠른 검출이 가능하다. 시뮬레이션 및 실험을 통하여 기존의 주파수검출기법인 영점검출기법과 가상의 2상 PLL을 이용한 주파수 검출과 제안하는 알고리즘을 비교하고 그의 우수성을 검증하였다.

Positive Feedback을 이용한 무효전력 P&O 단독운전 검출기법 (Reactive Power P&O Islanding Detection Method using Positive Feedback)

  • 이종원;박성열;이재연;최세완
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.410-416
    • /
    • 2022
  • A grid-connected inverter with critical loads uses mode transfer control to supply stable voltage to the load. An islanding detection method should also be used to quickly detect the grid fault and disconnect the inverter from the grid. However using the existing islanding detection method to detect islanding is difficult due to the small fluctuation of the voltage and frequency of the point of common coupling. This study proposes a reactive power P&O islanding detection method by using the positive feedback technique. The proposed method always injects a small variation of reactive power. When a grid fault occurs, the injected reactive power accelerates the reactive power injection reference. As a result, the reactive power reference value and the sensed reactive power become mismatched, and islanding is detected. Reducing the amount of real-time injected reactive power results in high efficiency and power factor. The simulation and experimental results of a 3 kW single-phase inverter are provided to verify the proposed islanding detection method.

계통연계형 태양광발전시스템의 새로운 단독운전 검출기법 (Novel islanding detection method for grid connected PV system)

  • 정영석;소정훈;유병규;유권종;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1705-1707
    • /
    • 2005
  • This paper proposes a novel active frequency drift(AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic(PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction(cf) enables the islanding detection to drift up(or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD methods, which have a certain value of cf only, is inefficient and difficult to design the appropriate cf value analytically to meet the limit of harmonics. In this paper, the periodic chopping fraction based on an AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with the power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also good performance of islanding detection compare with the conventional AFD method.

  • PDF