DOI QR코드

DOI QR Code

Performance Improvement of an Anti-Islanding Algorithm using the Variation of Reactive Power with an Improved DFT Method

개선된 DFT을 이용한 무효전력변동 단독운전 검출기법의 성능 개선

  • Received : 2010.02.23
  • Accepted : 2010.03.26
  • Published : 2010.06.20

Abstract

This paper proposes a new anti-islanding method for single-phase grid-connected photovoltaic (PV) systems using Goertzel algorithm. The proposed scheme is based on inducing increases or decreases of frequencies of load voltage and current that is in the form of existences or periodical variations of the reactive power components. The frequency detection is needed to apply this power variation method to the grid-connected power converter. The proposed method is able to get a fast detection for anti-islanding without the effect of harmonics and noises. The simulation and experiment results validate the effectiveness of the proposed method.

본 논문에서는 무효전력변동기법을 사용하여 단독운전을 검출을 하기 위해서 선행되어야 하는 주파수 검출 방법 중에서 개선된 이산푸리에변환(Discrete Fourier Transform; DFT), 즉 Goertzel 알고리즘을 이용한 단독운전 검출기법을 제안한다. 실제 태양광 발전 시스템의 설치를 위해서는 전기사고나 시스템에 악영향을 유발하는 단독운전 검출기법의 연구가 선행되어야 한다. 적용하는 주파수 검출방법은 Goertzel 알고리즘을 이용한 기법으로 기존의 영점검출기법과 가상의 2상 PLL(Phase Locked Loop)에 비하여 외란의 영향에 강인하며 빠른 검출이 가능하다. 시뮬레이션 및 실험을 통하여 기존의 주파수검출기법인 영점검출기법과 가상의 2상 PLL을 이용한 주파수 검출과 제안하는 알고리즘을 비교하고 그의 우수성을 검증하였다.

Keywords

References

  1. S.P. Chowdhury, S. Chowdhury, and P.A. Crossley, "Islanding protection of active distribution networks with renewable distributed generator: A comprehensive survey", Electric Power Systems Research 79, pp. 984-992, 2009. https://doi.org/10.1016/j.epsr.2008.12.012
  2. B. Yu, M. Matsui, J. So, and G. Yu, "A high power quality anti-islanding method using effective power variation", Solar Energy, Vol. 82, No. 4, pp. 268-378, April, 2008.
  3. F. D. Mango, M. Liserre, and A. Dell'aquila, "Overview of Anti-Islanding Algorithms for PV System. Part 2: Active Methods", Power Electronics and Motion Control Conference, pp. 1884-1889, Aug, 2006.
  4. P. Mahat, Z. Chen, and B. J. Birgitte, "Review of Islanding Detection Methods for Distributed Generation", Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies, pp. 2743-2748, 2008, April.
  5. Z. Ye, A. Kolwalkar, Y. Zhang, P. Du, and R. Walling, "Evaluation of anti-islanding schemes based on nondetection zone concept", IEEE Trans. on Power Electronics, Vol. 19, No. 5, pp. 1171-1176, 2004. https://doi.org/10.1109/TPEL.2004.833436
  6. M. E. Ropp, "Analysis and Performance Assessment Of the Active Frequency Drift Method Of Islanding prevention", IEEE Trans. on Energy Conversion, Vol. 14, No. 3, pp. 811-816, 1999.
  7. J. W. Choi, Y. K. Kim, and H. G. Kim, "Digital PLL control for single-phase photovoltaic system", IEE Proceedings Electric Power Applications, Vol. 153, No. 1, pp. 40-46, 2006. Jan. https://doi.org/10.1049/ip-epa:20045225
  8. E. Jacobsen, R. Lyons, "The sliding DFT", IEEE Signal Processing Magazine, Vol. 20, No. 2, pp. 74-80, 2003, March. https://doi.org/10.1109/MSP.2003.1184347
  9. K. P. Sozanski, "Sliding DFT Control Algorithm for Three-Phase Active Power Filter", IEEE Applied Power Electronics Conference and Exposition 2006, pp. 1223-1229, 2006, March.
  10. 김재형, 지용혁, 원충연, 정용채, "개선된 DFT를 이용한 위상 추종방법", 전력전자학술대회 논문집, pp. 91-93, 2008. 6.

Cited by

  1. High Precise Measurement of Grid-Connected Inverter using DFT vol.17, pp.2, 2012, https://doi.org/10.6113/TKPE.2012.17.2.93