Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load  

Oh, Hyeong-Min (Dept. of Electrical & Information Eng., Seoul Nat'l Univ. of Science and Technology)
Choi, Se-Wan (Dept. of Electrical & Information Eng., Seoul Nat'l Univ. of Science and Technology)
Kim, Tae-Hee (Doosan Heavy Industries & Construction Co., Ltd.)
Lee, Gi-Pung (Doosan Heavy Industries & Construction Co., Ltd.)
Lee, Tae-Won (Doosan Heavy Industries & Construction Co., Ltd.)
Publication Information
The Transactions of the Korean Institute of Power Electronics / v.17, no.4, 2012 , pp. 315-321 More about this Journal
Abstract
The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).
Keywords
indirect current control; active anti-islanding; utility-interactive inverter; critical load;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Z. Yao, L. Xiao, Y. Yan, "Seamless Transfer of Single-Phase Grid-Interactive Inverters between Grid-Connected and Stand-Alone Modes," IEEE Trans. Power Electron., Vol. 25, No. 6, pp. 1597-1603, Jun. 2010.   DOI   ScienceOn
2 J. Kwon, S. Yoon, S. Choi, "Indirect Current Control for Seamless Transfer of Three-Phase Utility Interactive Inverters," IEEE Trans. Power Electron., Vol. 27, No. 2, pp. 773-781, Feb. 2012.
3 F. D. Mango, M. Liserre, A. Dell'Aquila, A. Pigazo, "Overview of Anti-Islanding Algorithms for PV Systems. Part I:Passive Methods," Power Electronics and Motion Control Conf., pp. 1878-1883, 2006.
4 IEEE Standard for Interconnecting Distributed Resources With Electric Power Systems, IEEE 1547, 2003.
5 N. Pogaku, M. Prodanovic, and T. C. Green, "Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid," IEEE Trans. Power Electron., Vol. 22, No. 2, pp. 613-625, Mar. 2007.
6 R. Tirumala, N. Mohan, and C. Henze, "Seamless transfer of grid-connected PWM inverters between Utility-Interactive and Stand-Alone Modes," IEEE APEC 2002, pp. 1081-1086, 2002.
7 G. Shen, D. Xu, X. Yuan, "A Novel Seamless Transfer Control Strategy Based on Voltage Amplitude Regulation for Utility-interconnected Fuel cell Inverters with an LCL-filter," IEEE PESC 2006, pp. 1-6, 2006.
8 S. Jung, Y. Bae, T. Yu, S. Choi, H. Kim. "A Low Cost Utility Interactive Inverter for Residential Fuel Cell Generation," IEEE Trans. Power Electron., Vol. 22. pp. 2293-2298, Nov. 2007.   DOI
9 L. Wang, C. Singh, A. Kusiak, "Guest Editorial: Special Issue on Integration of Intermittent Renewable Energy Resources into Power Grid," IEEE System Journal, Vol. 6. pp. 2-3, March 2012
10 T. Hwang, K. Kim, B. Kwon, "Control strategy of 600kW E-BOP for molten carbonate fuel cell generation system," ICEMS 2008, pp. 2366-2371, 2008.