관 경사출구에 부착된 플랜지가 음향반사계수에 미치는 영향 (The effect of the flange attached to the inclined exit of tube on the sound reflection coefficient)

  • 백두산;양윤상;이동훈;조재형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.618-621
    • /
    • 2014
  • This research is to review the possibility of reducing the noise radiated from the tube exit by controling the sound reflection coefficient at the inclined exit. The sound reflection coefficient at the inclined exit of flanged tube was measured by both transfer function method and standing wave ratio method. Accuracy on the sound reflection coefficient measured by transfer function method was verified through comparison with sound reflection coefficient measured by standing ratio method. The flanged tube had lower sound reflection coefficient than the tube which have no flange. Also the sound reflection coefficient was decreased in accordance with increasing the inclined angle of unflanged tube.

  • PDF

Measurement of Refractive Index of Solid Medium by Critical Angle Method When Air Gap is Present

  • Lim, Hwan-Hong;Kwon, Moon-Soo;Choi, Hee-Joo;Kim, Byoung-Joo;Cha, Myoung-Sik
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.210-214
    • /
    • 2008
  • A critical angle method was used to measure the index of refraction of a solid medium when an air gap between the prism and the medium is present. The gap effect was analyzed both numerically and experimentally. Since the total internal reflection is severely disturbed by the large gap, determination of the critical angle and the resulting refractive index becomes ambiguous and inaccurate. By using an index matching fluid, we could determine the index of refraction with an uncertainty of ${\pm}2{\times}1^{-3}$ even when the gap is as large as 1 ${\mu}m$.

지형측량을 위한 무 프리즘 토털스테이션 정확도 평가 (Accuracy Evaluation of Non-prism Total Station for Topographic Surveying)

  • 서동주
    • 한국측량학회지
    • /
    • 제24권5호
    • /
    • pp.433-441
    • /
    • 2006
  • 최근 전자기술의 발달로 대상물에 접촉하지 않고, 장비에서 발사된 레이저가 측정대상물에 직접 반사되어 거리를 측정 가능하게 하였다. 더욱이 3차원위치를 결정할 수 있는 무 프리즘 토털스테이션이 등장하여 도로, 공항, 항만 등의 토목분야 뿐 아니라 구조물변위, 계측 등의 건축분야에 그 활용이 증대되고 있다. 따라서 본 연구에서는 무 프리즘 토털스테이션의 정확도를 평가하기 위하여 관측거리에 따른 재료 및 반사각도별로 관측하여 정확도를 분석하였고, 그 활용성을 위하여 지형측량에 적용하였다. 연구한 결과는 무 프리즘 토털스테이션은 반사각도가 $90^{\circ}$일 때는 재료와 상관없이 매우 양호한 값으로 분석되었다, 점차적으로 반사각도가 예각으로 증가할 때 RMSE는 높아지는 양상이 보였다. 그리고 관측거리에 따른 재료 및 반사각도별로 회귀분석 한 결과, 관측거리와 반사각도는 상관성이 있는 것으로 판단되며, 재료와는 상관성이 없는 것으로 분석되었다. 일반적인 지형측량에 있어서 무프리즘 토털스테이션을 적절히 활용한다면, 교통의 흐름이 많은 곳의 도로, 경사각이 높은 암벽의 절리면, 기타 위험지역에서 측량자의 안전과 신속한 측량작업을 제공할 것으로 판단된다.

플랩형 부유 방파제의 파랑 반사 및 전달 특성 (Wave Reflection and Transmission Characteristics of Flap-type Floating Breakwaters)

  • 정신택;박우선;김정대
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.2141-2145
    • /
    • 2008
  • 저면에 힌지로 연결된 3종류의 부유 플랩 시스템을 대상으로 수리모형실험을 실시하였다. 이 시스템은 입사파를 반사시키고, 구조적 감쇄 및 점성 감쇄를 이용하여 파랑에너지를 감소시켜 차폐 해역을 제공한다. 다양한 파랑조건에 대하여 파랑의 반사, 전달, 플랩의 회전각 등을 분석하였다. 외해 날개벽을 부착한 형태가 파랑의 전달을 최소화시킬 수 있다.

  • PDF

동해 천해환경에서 측정된 중주파수 전달손실 측정: Rayleigh 및 HFBL 모델과의 비교 (Measurements of mid-frequency transmission loss in shallow waters off the East Sea: Comparison with Rayleigh reflection model and high-frequency bottom loss model)

  • 이대혁;오래근;최지웅;김성일;권혁종
    • 한국음향학회지
    • /
    • 제40권4호
    • /
    • pp.297-303
    • /
    • 2021
  • 천해 환경에서 음파가 장거리 전파되는 경우, 해저면의 비균질성으로 인해 일반적으로 사용하는 Rayleigh reflection 모델을 적용한 음파전달 모의 결과보다 더 큰 전달손실을 보이는 것으로 알려지고 있다. 이에 따라 미 해군은 경험식 기반의 해저면 반사손실(High-Frequency Bottom Loss, HFBL) 모델을 적용하여 음파 전달을 예측하고 있다. 본 연구에서는 여름철 동해 천해환경에서 중주파수(2.3 kHz, 3 kHz)를 이용한 해상실험 전달손실 측정 및 분석이 수행되었다. BELLHOP 모델을 통해 고유음선을 추적한 결과, 임계각보다 낮은 수평입사각에 대해서만 음파가 수 km 이상 장거리 전파되었으며, Rayleigh reflection 모델 기반의 전달손실 예측값과 실측 전달 손실 값과의 차이는 전달거리가 증가함에 따라 점차 증가하는 경향을 보였다. 큰 수평입사각 영역에서 Rayleigh reflection 모델과 HFBL 모델을 비교하여 HFBL의 입력값인 해저면 province 값을 추정한 후, 이를 적용한 전달 손실을 모의하여 실측 전달 손실 값과 비교하였다. 그 결과 BELLHOP 모델의 반사 손실 모델로 경험식 기반의 HFBL을 적용하여 전달 손실을 모의했을 때, 실측 전달 손실과 일치하는 것을 확인할 수 있었다.

자기효과를 이용한 광 Scanner의 반사각 개선 (Improvement of Reflection Angle of Optical Scanner Utilizing Magnetic Effect)

  • 김흥근;박경일;신광호;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1718-1720
    • /
    • 2004
  • This paper is focused on the improvement of reflection angle of an optical scanner by changing a shape of a torsion bar attached with an optical scanner reflector(mirror). In order to improve the light efficiency of the optical scanner by virtue of the magnetic effect, which tiny magnets are attached under both ends of the optical scanner reflector. and hence the optical scanner reflector was operated in relatively lower driving voltage. By changing the torsion bar's shape I type into S type, we've got the lower resonant frequency(32.5Hz) of an optical scanner than that of conventional one(50Hz). According to these results. The reflection angle of an optical scanner with magnets was much larger in the range of about 14.8$^{circ}$ without a magnet. By making use of a magnetic actuator instead of a conventional electrostatic actuator, the optical scanner was less influenced from outdoor dust or moisture.

  • PDF

RLS-90 및 CRTN 모델에 의한 도로 인접건물에서의 도로소음 영향 예측 및 고찰 (Prediction and Evaluation of the Road Traffic Noise according to the Conditions of Road-side Building Using RLS-90 and CRTN Model)

  • 이장욱;김명준
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.425-432
    • /
    • 2009
  • Recently, reduction of road traffic noise in residential buildings has become one of the most important subjects. To reduce the road traffic noise, noise impact assessment by the road traffic prediction model is required before building construction. For reasonable road traffic noise prediction, it is required to analysis of various factors in road traffic prediction models. This paper was studied the road traffic noise propagation factors such as distance from road to building, receiver height, alignment angle of building and reflection coefficient of the building facade by two calculation models, RLS-90 and CRTN. The result showed that noise reduction was generally higher at bottom stories by ground absorption effect. The reflection coefficient of the building facade was affect of additional sound pressure level by facade reflecting. And alignment angle of building at $90^{\circ}$ was performed effective noise reduction better than $0^{\circ}$.

Reflection of plane waves from the boundary of a thermo-magneto-electroelastic solid half space

  • Singh, Baljeet;Singh, Aarti
    • Coupled systems mechanics
    • /
    • 제10권2호
    • /
    • pp.143-159
    • /
    • 2021
  • The theory of generalized thermo-magneto-electroelasticity is employed to obtain the plane wave solutions in an unbounded, homogeneous and transversely isotropic medium. Reflection phenomena of plane waves is considered at a stress free and thermally insulated surface. For incidence of a plane wave, the expressions of reflection coefficients and energy ratios for reflected waves are derived. To explore the characteristics of reflection coefficients and energy ratios, a quantitative example is set up. The half-space of the thermo-magneto-electroelastic medium is assumed to be made out of lithium niobate. The dependence of reflection coefficients and energy ratios on the angle of incidence is illustrated graphically for different values of electric, magnetic and thermal parameters.

PCS 시스템 셀설계를 위한 전파예측 모델 (A Propagation Prediction Model for Planning a Cell in the PCS System)

  • 김송민
    • 전자공학회논문지T
    • /
    • 제35T권3호
    • /
    • pp.103-112
    • /
    • 1998
  • 본 논문에서는 전파경로를 해석할 때 기하광학적 영상법과 전파송출법의 단점을 보완하여 계산속도를 향상시킴은 물론 전파의 입사각과 반사각에 따른 전파경로, 진행파의 수평경로 그리고 반사횟수를 동시에 처리 할 수 있는 알고리즘을 제안하였다. 제안 알고리즘을 활용한 전파예측모델을 제안하고, 반복된 반사에 의해 전파가 진행하는 경우, 임의 지점의 전파경로 손실을 쉽게 계산할 수 있다. 마지막으로 광주광역시 광산구 월곡동에 있는 SK텔레콤 전남지사 주변의 실제 도로 상황을 샘플로 취하여 제안 전파예측 모델을 시뮬레이션하여, 일반적인 타당성을 입증하였다.

  • PDF

경사형 타공판을 이용한 소파장치 개발 (Development of a Wave Absorbing System Using an Inclined Punching Plate)

  • 조일형;홍석원
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2004
  • In this paper, the performance of a wave absorbing system using an inclined punching plate, was investigated. Using the multi-domain boundary element method (BEM), the reflection coefficients of an inclined punching plate were tested with various design parameters, such as inclined angle, porosity, and wave frequencies. To confirm the numerical solutions, the systematic model test was conducted at 2-D tank and square tank. The numerical results were in good agreement with the experimental results within the entire frequency range. It was found that an inclined punching plate had an excellent wave absorbing efficiency, compared to a horizontal one. Also, the optimal range of an inclined angle had an excellent wave absorbing efficiency, compared to a horizontal one the optimal range of the inclined angle is 10°<β<20°. The developed wave absorber was installed at KRISO's square basin, and is working effectively for various model tests.