DOI QR코드

DOI QR Code

Measurement of Refractive Index of Solid Medium by Critical Angle Method When Air Gap is Present

  • Received : 2008.08.19
  • Accepted : 2008.09.11
  • Published : 2008.09.25

Abstract

A critical angle method was used to measure the index of refraction of a solid medium when an air gap between the prism and the medium is present. The gap effect was analyzed both numerically and experimentally. Since the total internal reflection is severely disturbed by the large gap, determination of the critical angle and the resulting refractive index becomes ambiguous and inaccurate. By using an index matching fluid, we could determine the index of refraction with an uncertainty of ${\pm}2{\times}1^{-3}$ even when the gap is as large as 1 ${\mu}m$.

Keywords

References

  1. G. P. Agrawal, Nonlinear fiber optics (Academic Press, San Diego 1989), Ch. 3
  2. R. W. Boyd, Nonlinear optics (Academic Press, San Diego 1992), Ch. 2
  3. N. E. Yu, Y. Lee, C. Jung, and J. Lee, "Efficient singlepass optical parametric generation and amplification using a periodically poled stoichiometric lithium tantalate," J. Opt. Soc. Korea, vol. 11, no 4, pp. 192-195, 2007 https://doi.org/10.3807/JOSK.2007.11.4.192
  4. W. L. Bond, "Measurement of the refractive indices of several crystals," J. Appl. Phys., vol. 36, pp. 1674-1677, 1965 https://doi.org/10.1063/1.1703106
  5. M. S. Shumate, "Interferometric Measurement of Large Indices of Refraction," Appl. Opt., vol. 5, no.2, pp. 327-331, 1966 https://doi.org/10.1364/AO.5.000327
  6. J. F. H. Nicholls, B. Henderson, and B. H. T. Chai, "Accurate determination of the indices of refraction of nonlinear optical crystals," Appl. Opt. vol. 36, no. 33, pp. 8587-8594, 1997 https://doi.org/10.1364/AO.36.008587
  7. U. Schlarb and K. Betzler, "Interferometric measurement of refractive indices of $LiNbO_3$," Ferroelectrics, vol. 126, no. 1, pp. 39-44, 1992 https://doi.org/10.1080/00150199208227032
  8. T. Yamaguchi and H. Takahashi, "Ellipsometric method for separate measurements of n and d of a transparent film," Appl. Opt., vol. 14, no. 8, pp. 2010-2015, 1975 https://doi.org/10.1364/AO.14.002010
  9. A. C. Adams, D. P. Schinke, and C. D. Capio, "An evaluation of the prism coupler for measuring the thickness and refractive index of dielectric films on silicon substrates,"J. Electrochem. Soc., vol. 126, pp. 1539-1543, 1979 https://doi.org/10.1149/1.2129324
  10. R. Ulrich and R. Torge, "Measurement of Thin Film Parameters with a Prism Coupler," Appl. Opt., vol. 12, no. 12, pp. 2901-2908, 1973 https://doi.org/10.1364/AO.12.002901
  11. www.atago.net
  12. H. Li and S. Xie, "Measurement method of the refractive index of biotissue by total internal reflection," Appl. Opt., vol. 35, no.10, pp. 1793-1795, 1996 https://doi.org/10.1364/AO.35.001793
  13. Q. W. Song, C. Y. Ku, C. Zhang, R. B. Gross, R. R. Birge, and R. Michalak, "Modified critical angle method for measuring the refractive index of bio-optical materials and its application to bacteriorhodopsin," J. Opt. Soc. Am. B., vol. 12, no. 5, pp. 797-803, 1995 https://doi.org/10.1364/JOSAB.12.000797
  14. H. Onodera, I. Awai, and J. Ikenoue, "Refractive-index measurement of bulk materials: prism coupling method," Appl. Opt., vol. 22, no. 8, pp. 1194-1197, 1983 https://doi.org/10.1364/AO.22.001194
  15. J. D. Jackson, Classical Electrodynamics, $3^{rd}$ ed. (John Wiley and Sons, New York 1999), Ch. 7
  16. I. H. Malitson, "Interspecimen comparison of the refractive index of fused silica," J. Opt. Soc. Am., vol. 55, pp. 1205-1209, 1965 https://doi.org/10.1364/JOSA.55.001205
  17. J. H. Wray and J. T. Neu, "Refrective index of several glasses as a. function of wavelength and temperature," J. Opt. Soc. Am., vol. 59, pp. 774-776, 1969 https://doi.org/10.1364/JOSA.59.000774
  18. B. Edlen,"The refractive index of air,"Metrologia, vol. 2, pp. 71-80, 1966 https://doi.org/10.1088/0026-1394/2/2/002
  19. www.nist.gov

Cited by

  1. A study on the brilliance by critical angle of gem and measurement theory of refractive index using refractometer vol.21, pp.3, 2011, https://doi.org/10.6111/JKCGCT.2011.21.3.105
  2. Nondestructive Optical Measurement of Refractive-index Profile of Graded-index Lenses vol.13, pp.4, 2009, https://doi.org/10.3807/JOSK.2009.13.4.468
  3. Refractive index measurement of nanoparticles by immersion refractometry based on a surface plasmon resonance sensor vol.654, 2016, https://doi.org/10.1016/j.cplett.2016.05.013