A research on the performance of retrofit anchors was conducted using adhesives for rehabilitation. From the pull-out tests of the chemical anchors, the effect of the hole diameter, spacer, temperature, moisture, embedment depth, and aging time were investigated. The spacer did not directly increased the pull-out load hilt increased post-yielding resistance therefore the ductility of the retrofit anchors. When the hole was cleaned and dried after the immersion, the pull-out load was greatly increased compared to the wet hole. A design equation was unposed depending on the embedment depth of the anchor bolt.
포장(包裝) 용적(容積) 감소에 따른 수송비(輸送費) 절감(節減) 효과(效果)가 있어 조립시(組立式) 탁자류(卓子類) 가구(家具)의 제작(製作)에 널리 쓰이는 CBA(corner block with anchor bolt) 접합방식(接合方式)은 일정기간(一定期間) 사용(使用)함에 따라 접합부위(接合部位)가 약해지고 그 결과(結果) 구조(構造)가 불안정(不安定)하게 되는 반강접합(半剛接合)(semi-rigid joint) 특유(特有)의 결점(缺點)도 지니고 있다. 따라서 본(本) 연구(硏究)에서는 CBA 접합(接合) 강도(强度)에 영향하는 주요(主要) 설계(設計) 인자(因子)로서 side rail 규격, corner block의 side rail에의 부착시(時) 보강재(補强材)의 효과(效果) 및 corner block관통 anchor bolt의 사용(使用) 수(數) 그리고 corner block의 형태등(等)의 평가(評價)를 하기 위해 22개(個)의 접합군(接合群) 별(別)로 총(總) 88개(個)의 table section 시험체(試驗體)를 제작(製作)한 후(後)그들의 강성(剛性) 계수(係數)(Z - 값) 및 유효강도(有效强度)를 수평 하중(荷重)에 의한 변형측정(變形測定) 실험(實驗)을 통해 결정(決定)한 후 설계(設計) 인자별(因子別) 효과(效果)를 비교 분석(分析)하였다. 분석결과(分析結果), side rail의 높이 증대(增大) 및 corner block 부착시(時) PVAc 수지(樹脂)의 사용효과(使用效果)가 뚜렷하여 유효강도(有效强度)의 유의적(有意的) 향상(向上)을 나타냈고 anchor bolt의 효과(效果) 역시 2개 사용시(使用時)가 1개 사용시(使用時) 보다 훨씬 큰 것으로 나타났다. 또 side rail 높이 와 anchor bolt 사용(使用) 수(數)간에는 상호작용(相互作用) 효과(效果)도 있었다. 그러나 side rail의 두께 효과(效果)는 22mm에서 25mm로 증대(增大)시켰을때 뚜렷한 상승 경향(傾向)은 보여주지 못했다. 한편 corner block의 형태는 MDF를 주재료(主材料)로 사용(使用)한 탁자(卓子) 설계시(設計時)는 두께 25mm, 높이 100mm의 side rail에 PVAc 수지(樹脂)로 보강(補强)하고 mitered corner block에 2개(個)의 anchor bolt를 관통시킨 경우가 유효강도(有效强度) 3171.7 kgf-cm로 22개의 접태군(接台群)들 중 최대치(最大値)를 나타냄으로써 miter type이 rectangular type보다 바람직한 것으로 나타났다. 결론적(結論的)으로 자재(資材)의 효과적(效果的) 이용(利用)을 통한 생산비(生産費) 절감(節減)과 동시(同時)에 구조(構造)의 안정(安定)된 강도적(强度的) 측면(側面)을 고려할 때, 두께 22mm, 높이 75mm의 MDF side rail에 mitered corner block을 PVAc 수지(樹脂)와 나사못을 이용하여 부착한 후(後) 2개(個)의 anchor bolt를 관통시키는 방법(方法)을 가장 합리적(合理的)인 MDF 사용(使用) 조립시(組立式) 탁자(卓子) 설계(設計) 방안(方案)으로 제시(提示)하는 바이다.
플랜트의 유황 저장 탱크는 강재로 구성되며, 탱크 저면은 앵커볼트에 의해 Ring Wall 형상의 콘크리트 기초와 연결된다. 탱크 내 유황이 내부 열원에 의해 고온상태를 유지하기 때문에, 유황 저장 탱크는 상온의 유체를 저장하는 다른 탱크에 비해 큰 체적팽창을 겪게 된다. 일반적으로 탱크 기초의 구조설계는 기초의 내외부의 온도차를 하중으로 적용한 구조해석이 수행되는데, 이 방법은 탱크의 열팽창 특성이 앵커볼트에 의해 집중하중 형태로 콘크리트 기초에 전달되는 현상을 고려할 수 없다. 이는 온도하중의 영향을 과소평가하게 되며, 앵커볼트에 인접한 콘크리트의 균열을 야기한다. 본 연구는 앵커볼트에 의한 온도 하중전달 메커니즘을 고려한 하중 평가식을 제안함으로써, 콘크리트 기초에 작용하는 하중을 보다 합리적으로 결정하고자 한다. 이를 위해 탱크 바닥판과 앵커볼트가 포함된 유한요소모델을 이용해 앵커볼트 개수 증감에 따른 온도하중의 변화를 분석하였으며, 분석결과를 이론해와 결합해 앵커볼트에 의해 전달되는 하중을 평가할 수 있는 명시적인 형태로 해를 제시하였다. 제안된 식의 유효성을 확인하기 위해 실제 플랜트 현장의 유황 저장 탱크 설계에 적용하였으며, 실무적으로 사용 가능함을 보였다.
This paper investigates the seismic behavior of an electrical cabinet considering the influence of equipment-anchor-interaction (EAI) that is generally not taken into consideration in a decoupled analysis. The hysteresis behavior of an anchor bolt in concrete was thereby considered to highlight this interaction effect. To this end, the experimental behavior of an anchor bolt under reversed cyclic loading was taken from the recently developed literature, and a numerical model for the anchor hysteresis was developed using the component approach. The hysteresis properties were then used to calibrate the multi-linear link element that is implemented as a boundary condition for the cabinet incorporating the EAI. To highlight this EAI further, the nonlinear time history analysis was performed for a cabinet considering the hysteresis behavior comparative to a fixed boundary condition. Additionally, the influence on the seismic fragility was evaluated for the operational and structural condition of the cabinet. The numerical analysis considering the anchor hysteresis manifests that the in-cabinet response spectra (ICRS) are significantly amplified with the corresponding reduction in the seismic capacity of 25% and 15% for an operational and structural safety condition under the selected protocols. Considering the fixed boundary condition over a realistic hysteresis behavior of the anchor bolt is more likely to overestimate the seismic capacity of the cabinet in a seismic qualification procedure.
본 연구에서는 콘크리트 궤도 침목 내에 설치되는 인서트에 예기치 못하게 침투된 수분의 결빙압이 앵커볼트의 인발강도에 미치는 영향을 유한요소해석을 통해 고찰하였다. 3차원 유한요소해석모델은 콘크리트 침목의 현장실험 결과, 도면 및 레일체결장치의 제원 실측치를 기반으로 수립되었으며, 비선형구성방정식과 파괴 모델은 측정된 압축강도로부터 CEB-FIP 1990 모델코드를 이용하여 추정하였다. 해석모델의 적정성은 철도기술연구원에서 수행한 현장 인발시험 결과 및 실내시험 결과와의 비교를 통해 확인하였다. 다양한 인자, 즉 결빙위치, 앵커볼트 초기 체결력의 크기 및 콘크리트 압축강도에 따른 해석을 수행하였으며, 그 결과를 제시하였다. 해석결과에 의하면, 매립전내 침투수의 결빙력은 균열손상의 가장 가능성 있는 직접적인 원인 중 하나로 간주될 수 있음을 확인하였다. 또한, 외측매립전의 결빙력이 내측 매립전 보다 작은 것으로 나타났으나 그 차이는 크지 않았다.
An experimental study was carried out to determine pullout behavior of a new type of anchor bolt that used deformed reinforcement and a commercial adhesive. Concrete slabs and columns with about 20-MPa compressive strength were used for 136 pullout tests performed. Test variables included anchor diameter (10 mm ~ 32 mm). embedment depth (10$\Phi$ or 15$\Phi$), edge effect. and Presence of transverse reinforcement in existing concrete. In Tyre-S test. where the edge or reinforcing steel effect was not included, the anchor Pullout strengths increased with increasing anchor diameters. Anchors with 15$\Phi$ embedment depth had higher Pullout strengths than those with 100 embedment depth The largest average Pullout load of 208 kN was determined for anchors made with D25 reinforcement and with 15$\Phi$ embedment depth. In Type-E tests, where the anchors were installed close to the edge of existing concrete, there were reductions in pullout strengths when compared to those determined in Type-S tests. In Type-ER tests, influence of the reinforcement in existing concrete on the anchor pullout strengths was examined using reinforced concrete and plain concrete columns Test results indicated that existing transverse reinforcement (column ties) did not help increase the pullout strength. The overall pullout test results revealed that the new anchor bolt can develop large pullout strengths while the anchors can be made of materials that are readily available in the market.
From the result of precise field investigation and stability examination for the rock slope, following results were acquired. 1. The weathering rock itself, existing fault zone and underground water complexly effect cut slope so that plane destruction may appear by fault zone. 2. The reinforcement force was decided by the result of limit equilibrium. 3. For rock cut slope, the Rock Bolt was judged as the most proper method to the cut slope as comparing/analyzing Rock Anchor, Rock Bolt and method after relaxing the slope.
The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.
복층터널은 도심지에서 대심도로 시공되는 특성이 있으므로 복층터널용 수직구는 급기 및 배기구, 대피통로 계단, 엘리베이터, 배전시설, 접속터널 등의 설치공간의 확보가 필요하다. 또한 복층터널용 수직구는 도심지에 시공되는 특성상 공사영향 최소화를 위하여 터널굴착 완료 후 수직구 내부 콘크리트 구조물의 급속시공이 필요하다. 따라서 수직구 내부 슬래브 및 계단용 콘크리트 시공의 프리캐스트화가 필요하며 이러한 수직구 내부 프리캐스트 구조물 지지를 위한 브래킷의 급속시공기술이 필요하다. 브래킷 형태 사례조사 결과 현장타설 방식, 프리캐스트 방식, 철재브래킷 방식 등이 있는데 본 연구에서는 시공속도 향상을 고려하여 경제성이 양호하고 시공성이 우수한 철재브래킷을 개선한 새로운 브래킷에 대하여, 직선형 매립 앵커볼트와 꺾임형 매립 앵커볼트에 대한 구조성능시험결과 소요하중 지지능력을 확보하는 것을 확인하였고 꺾임형 매립 앵커볼트의 하중지지능력이 보다 큰 것을 확인하였다.
비상디젤발전기는 원전의 안전성에 큰 영향을 미치는 매우 중요한 기기이다. 본 연구에서는 세 종류의 비상디젤발전기를 대상으로 가동중 진동을 계측하여 기초시스템에 따른 가동중 진동의 저감효과를 비교하였다. 대상 원전은 영광 5호기, 울진 2호기 및 울진 3호기 원전의 비상디젤발전기로 하였다. 영광 5호기와 울진 3호기의 비상디젤발전기는 동일한 종류의 비상디젤발전기로서 기초형식만 앵커볼트 고정과 스프링-댐퍼시스템을 이용한 면진으로 구분된다. 울진 2호기 비상디젤발전기는 기초부분에 seismic block을 설치하고 코일스프링을 이용하여 진동저감효과를 고려하였으므로 좋은 비교가 될 것이다. 이러한 진동계측의 목적은 기초형태에 따른 진동저감 효과를 비교해 보기 위함이다. 결과적으로 스프링-댐퍼 시스템이 진동저감과 시스템의 안정적 거동측면에서 좋은 효과를 보이고 있음을 알 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.