Browse > Article
http://dx.doi.org/10.9711/KTAJ.2019.21.3.363

A study on structural performance of steel brackets in vertical shaft connected to double-deck tunnel  

Shin, Young-Wan (Hakyong Engineering Co., Ltd.)
Min, Byeong-Heon (Dept. of Civil Engineering, Hoseo University)
Nam, Jung-Bong (Hakyong Engineering Co., Ltd.)
Lee, Sang-Hwan (Hakyong Engineering Co., Ltd.)
Publication Information
Journal of Korean Tunnelling and Underground Space Association / v.21, no.3, 2019 , pp. 363-375 More about this Journal
Abstract
Since the double-deck tunnel is deeply constructed in the city, it is necessary to secure the installation space of air supply and exhaust, escape passage stairs, elevator, distribution facilities and connection tunnels in the vertical shaft for the double-deck tunnel. Also, in order to minimize the effect of construction on adjacent area, it is necessary to construct the concrete structures at high speed in vertical shaft after tunnel excavation. Therefore, the slabs and the stairs in vertical shaft are needed to be constructed using precast concrete, and the rapid construction techniques of bracket for supporting the inner precast structure are needed. The bracket installation methods include cast-in-place concrete, precast concrete and steel. In this study, the improvement of the steel brackets with good economical efficiency and good workability was carried out in consideration of the improvement of the construction speed. We have developed a new bracket that is optimized through bracket shape improvement, anchor bolt position adjustment and quantity optimization. As a result of the structural performance test, it was confirmed that the required load supporting capacity was secured. As a result of structural performance test for bar type anchor bolt and bent anchor anchor bolt, it was confirmed that the required load carrying capacity was secured and that the load bearing capacity of bent anchor bolt was large.
Keywords
Vertical shaft; Steel brackets; Embeded anchor bolt; Structural performance test; Support capacity;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kang, S.H., Kim, D.H., Kim H.T., Song, S.W. (2017), "Study on the structure of the articulation jack and skin plate of the sharp curve section shield TBM in numerical analysis", Journal of Korean Tunnelling and Underground Space Association, Vol. 19, No. 3, pp. 421-435.   DOI
2 Kim, B.Y., Lee, D.S., Kim, T.K., Kim, Y.J. (2016), "A experimental study on the structural performance of precast bracket under precast road deck slab of double deck tunnel", Journal of the Korean Society of Civil Engineers, Vol. 37, No. 4, pp. 647-657.   DOI
3 Lee, H.S., Moon, H.K. (2016), "Numerical study on the connection type of inner-slab in double deck tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 18, No. 5, pp. 441-451.   DOI
4 Moon, H.K., Song, I.C., Kim, J.W., Lee, H.Y. (2017), "A study on the maintenance methods of the multi-purpose double-deck tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 19, No. 1, pp. 83-93.   DOI