Performance test of Chemical Anchor Bolts for Concrete Repair

콘크리트보수용 접착제를 이용한 Anchor Bolt의 인발지지력 산정에 관한 실험적 연구

  • Kim, Yon-Gon (Department of safety Engineering, Hankyong National University)
  • 김용곤 (한경대학교 안전공학과)
  • Published : 2002.06.30

Abstract

A research on the performance of retrofit anchors was conducted using adhesives for rehabilitation. From the pull-out tests of the chemical anchors, the effect of the hole diameter, spacer, temperature, moisture, embedment depth, and aging time were investigated. The spacer did not directly increased the pull-out load hilt increased post-yielding resistance therefore the ductility of the retrofit anchors. When the hole was cleaned and dried after the immersion, the pull-out load was greatly increased compared to the wet hole. A design equation was unposed depending on the embedment depth of the anchor bolt.

Keywords

References

  1. ACI Committee 349, Code requirements for nuclear safety related concrete structures (ACI 349-90), American Concrete Institute, Detroit, 1990
  2. Fuchs, W., Eligehausen, R., and Breen, J. E., 'Concrete capacity design (CCD) approach for fastening to concrete,' ACI Structural Journal, Vol. 92, No. 1, January-February 1995, pp. 73-94
  3. Cook, R. A., Collins, D. M., Klingner, R. E., and Polyzois, D., 'Load deflection behavior of cast-in-place and retrofit concrete anchors,' ACI Structural Journal, Vol. 89, No. 6, November- December 1992, pp. 639-649
  4. Choi, D., Kim, Y., 'Pull-out test of retrofit anchors using deformed reinforcement and adhesive,' KCI Concrete Journal, Vol. 11, No. 3, July 1999, pp. 201-210
  5. Choi, D., Kim, Y., 'Direct shear test of retrofit anchors using deformed reinforcement and adhesive,' K.CI Concrete Journal, Vol. 12, No. 1, January 2000, pp. 91-100