• Title/Summary/Keyword: Analytical performance

Search Result 2,982, Processing Time 0.027 seconds

Predictive analysis on explosive performance of methylnitroimidzole derivatives (메틸나이트로이미다졸 유도체의 화약성능 예측분석)

  • Rim, One Kwon
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.347-352
    • /
    • 2015
  • Chemical properties such as heat of formation and density of methylnitroimidazole derivatives were predicted and analyzed by using density functional theory (DFT). Successive addition of energetic nitro groups into an imidazole ring increases both the heat of formation and the density. Using the chemical property values computed by DFT, explosive performance was analyzed with the Cheetah program, and compared with those of TNT, RDX, and HMX, which are currently used widely in military systems. When both C-J pressure and detonation velocity were used as explosive performance, methyldinitroimidazole derivatives show better performance than TNT, while methyltrinitroimidzole is almost close to RDX. Since methylnitroimidazole derivatives have a good merit, i.e. low melting point for melt loading, they are forecasted to be used widely in various military and civilian application.

The Research on Consumers' Actual Value for Environmental Performance of houses (주택의 환경 성능에 대한 소비자의 실질적 가치에 대한 연구)

  • Park, Min-Sun;Hagishima, Aya;Chun, Chung-Yoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.318-323
    • /
    • 2008
  • First aim of this study is to investigate consumer's actual value for environment related performance of house by using three different method, Ranking, Analytical Hierarchy Process (AHP) and Conjoint Analysis method. Second aim is to estimate consumers' monetary value about environment related factor through Marginal Willing to Pay(MWTP), and third aim is to find out the difference of values between the groups classified according to respondents' characteristics. A questionnaire survey was carried out in Seoul in order to clarify the preference and monetary value of four selected attributes. They are environmental performance, residents' health, home automation and increase of floor area. As a result, people showed high values in the order of health, environmental consideration, increase of floor area and home automation. Moreover, it was found out that MWTP for environmental performance and health are higher than market price. In addition, the group of high age and group of female showed high values for the reduction of $CO_2$ emission

  • PDF

Dynamic stiffness analysis of steel-concrete composite beams

  • Li, Jun;Huo, Qiji;Li, Xiaobin;Kong, Xiangshao;Wu, Weiguo
    • Steel and Composite Structures
    • /
    • v.16 no.6
    • /
    • pp.577-593
    • /
    • 2014
  • An exact dynamic stiffness method is introduced for investigating the free vibration characteristics of the steel-concrete composite beams consisting of a reinforced concrete slab and a steel beam which are connected by using the stud connectors. The elementary beam theory is used to define the dynamic behaviors of the two beams and the relative transverse deformation of the connectors is included in the formulation. The dynamic stiffness matrix is formulated from the exact analytical solutions of the governing differential equations of the composite beams in undamped free vibration. The application of the derived dynamic stiffness matrix is illustrated to predict the natural frequencies and mode shapes of the steel-concrete composite beams with seven boundary conditions. The present results are compared to the available solutions in the literature whenever possible.

Performance Evaluation of Multibuffered Multistage Interconnection Networks under Nonuniform Traffic Pattern (복수버퍼를 가진 다단상호연결네트웍의 비균일 트래픽 환경하에서의 해석적 모델링)

  • Mun Yongsong
    • Journal of Internet Computing and Services
    • /
    • v.5 no.1
    • /
    • pp.41-49
    • /
    • 2004
  • Analytical performance evaluation is crucial for justifying the merit of the design of Multistage Interconnection Networks(MINs) in different operational conditions. While several analytical models have been proposed for the performance evaluation of MlNs, they are mainly for uniform traffics. Even the models for nonuniform traffics have various shortcomings. In this paper, an accurate model for the performance evaluation of multi buffered banyan-type MIN's under nonuniform traffic condition is obtained. The accuracy of proposed models are conformed by comparing with the results from simulation.

  • PDF

Mutation Analysis in β2-Adrenergic Receptor Gene by Denaturing High Performance Liquid Chromatography (DHPLC) (DHPLC를 이용한 β2-교감신경수용체 유전자에서의 돌연변이 분석)

  • Park, Sang-Bum;Oh, Chung-Hun;Kim, Jong-Wan;Jang, Won-Cheoul
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.190-195
    • /
    • 2002
  • We analysed mutation of ${\beta}_2$-adrenergic receptor gene that controls bronchial asthma by denaturing high performance liquid chromatography (DHPLC) according to ion-pair reversed-phase high performance liquid chromatography (IP-RP-HPLC). We extracted genomic DNA from 50 asthma patients, amplified DNA using PCR, and analysed PCR product by DHPLC. As a result, we obtained that mutation frequency was 15 (30%) among 50 cases. Consequently DHPLC mutation detection was confirmed that the result of direct sequencing was coincide exactly.

Analytical evaluation of a modular CFT bridge pier according to directivity

  • Kim, Dongwook;Jeon, Chiho;Shim, Changsu
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1193-1203
    • /
    • 2016
  • This paper focuses on the analytical behavior of modular circular concrete-filled tubular (CFT) column with enhanced bracing details. To design a full-scale bridge pier of multiple circular concrete-filled tubes, numerical analysis was used to evaluate structural performance according to load directivity. In previous research (Ma et al. 2012, Shim et al. 2014), low cycle fatigue failure at bracing joints was observed, so enhanced bracing details to prevent premature failure are proposed in this analysis. The main purpose of this research is to investigate seismic performance for the diagonal direction load without premature failure at the joints when the structure reaches the ultimate load. The ABAQUS finite-element software is used to evaluate experimental performance. A quasi-static loading condition on a modular bridge pier is introduced to investigate structural performance. The results obtained from the analysis are evaluated by comparing with load-displacement responses from experiments. The concrete-filled tubes with enhanced bracing details showed higher energy dissipation capacity and proper performance without connection failure for a diagonal load.

Performance Evaluation of Multistage Interconnection Networks under Nonuniform Traffic Pattern (비균일 트래픽 환경하에서 다단상호연결네트웍의 해석적 성능 모델링 및 평가)

  • Mun Young-song
    • Journal of Internet Computing and Services
    • /
    • v.4 no.5
    • /
    • pp.43-49
    • /
    • 2003
  • Analytical performance evaluation is crucial for justifying the merit of the design in different operational conditions. While several analytical models have been proposed for the performance evaluation of Multistage Interconnection Networks(MINs), they are mainly for uniform traffics. Even models for nonuniform traffics have several shortcomings such as they only consider output buffered structure or do not consider blocking conditions. In this paper the mere accurate models than any other ones so far have been proposed for the performance evaluation of banyan-type MIN's under nonuniform traffic condition is obtained. The accuracy of proposed model is conformed by comparing with the results from simulation.

  • PDF

Seismic retrofit of structures using added steel column friction dampers

  • Mohammad Mahdi Javidan;Asad Naeem;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • v.49 no.3
    • /
    • pp.257-270
    • /
    • 2023
  • In this study, the feasibility and applicability of a friction damper with a vertical installation scheme are investigated. This device is composed of a steel section and two friction hinges at both ends which dissipate seismic energy. Due to its small width and vertical installation scheme, the proposed damper can minimize the interference with architectural functions. To evaluate the performance of the proposed damper, its mechanical behavior is theoretically evaluated and the required formulas for the yield strength and elastic stiffness are derived. The theoretical formulas are verified by establishing the analytical model of the damper in the SAP2000 software and comparing their results. To further investigate the performance of the developed damper, the provided analytical model is applied to a 4-story reinforced concrete (RC) structure and its performance is evaluated before and after retrofit under the Maximum Considered Earthquake (MCE) hazard level. The seismic performance is thoroughly evaluated in terms of maximum interstory drift ratio, displacement time history, residual displacement, and energy dissipation. The results show that the proposed damper can be efficiently used to protect the structure against seismic loads.

Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber (소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가)

  • Lee, Suk-Jo;Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.344-354
    • /
    • 2005
  • This study was carried out to evaluate the performance of a small chamber sampling and analytical method for the measurement of total volatile organic compounds (TVOC) and formaldehyde (HCHO) emission from building materials. While VOC was determined by the adsorbent tube sampling and sequential thermal desorption coupled with GC/MSD analysis, formaldehyde sampled with DNPH-silica cartridge was analyzed by HPLC. Wide-range performance criteria such as repeatability, desorption efficiency, emission chamber recovery test, duplicate precision, breakthrough volume and method detection limits were investigated for the evaluation of small chamber method. The overall precision of the small chamber sampling and analytical methods was estimated within 20~30% for target compounds. In conclusion, this study demonstrated that the small chamber sampling and analytical method can be reliably applied for the measurement of building materials pollutants.

A Survey of Total Aflatoxins in Food Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Liquid Chromatography Tandem Mass Spectrometry(LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 식품 중 총아플라톡신 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hee;Cho, Sung-Hye;Park, Joon-Shik;Kwon, Eun-Young;Lee, Eun-Jin;Kim, So-Hee;Kim, Dai-Byung
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.488-493
    • /
    • 2007
  • A survey for total aflatoxins (aflatoxins $B_1$, $B_2$, $G_1$, and $G_2$) was conducted on 245 cereals and processed cereal products, and 148 nuts and processed nut products in Korea, for a total of 393 commercialized ed samples. The total aflatoxins were quantified by the immunoaffinity column clean-up method with high performance liquid chromatography (HPLC) - fluorescence detection (FLD), and were confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). Total aflatoxins(AFs) were detected in 37 samples (9.4% incidence), including 2 millet samples, 1 mixed cereal (sunsik), 1 powdered malt sample, 2 processed cereal products, 6 peanut samples, 22 peanut butter samples, and 1 sample each of almonds, adlay tea, and a processed nut product. The contamination levels were $0.04-2.65{\mu}g/kg$ for aflatoxin $B_1$, and $0.04-5.51{\mu}g/kg$ for total aflatoxins. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected aflatoxins, and all 37 samples showing aflatoxins by HPLC-FLD were confirmed by LC-MS/MS.