• Title/Summary/Keyword: Amount of switching

Search Result 171, Processing Time 0.034 seconds

The Relationship between Domain Switching and Acoustic Emission in (Pb,La)$TiO_3$ Ferroelectric Ceramacs ((Pb,La)$TiO_3$ 강유전체 세라믹에서 분역반전과 Acoustic Emission의 관계)

  • 최동구;최시경
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.6
    • /
    • pp.672-678
    • /
    • 1996
  • The relationship between domain switching and acoustic emission (AE) during poling was investigated using the tetragonal ferroelectric ceramics with composition of (Pb,La)TiO3+0.01MnO2 The amount of AE generation during poling increased with increasing dc electric field and raising temperature. It was confirmed that the change of the amount of AE generation with poling condition resulted from the difference of the amount of 90$^{\circ}$ domain switching and total amount of AE generation for 10 minutes was approximately proportional to the amount of 90$^{\circ}$domain switching. The A generations of two specimens which have different tetragonality rations(c/s rations) 15 at% and 24at% La-doped were also investigated. The sample with c/a ratio of 1.012 where 90$^{\circ}$ domains are dominate had larger amount of AE generation and 90$^{\circ}$ domain switching compared with the sample with c/a ratio of 1.004 where 180$^{\circ}$ domains are dominant.

  • PDF

The Effects of Customers' Chemyeon and Relationship Benefits on Switching Behavior for Apparel Purchases (의류소비자의 체면중시와 관계혜택이 전환행동에 미치는 영향)

  • Suh, Yong-Han
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.900-906
    • /
    • 2008
  • This study investigated factors influencing consumers' switching behavior in apparel purchasing situation. As customer switching behavior is getting more and more important, a considerable amount of researches have focused on how service providers acquire and sustain customers. The field of customers' switching behavior has been relatively well researched over the years, at least from the perspective of the cultural value(Chemyen). The purpose of this study is to understand customer' switching behavior to relationship benefits and Chemyeon. The sample was consisted on 182 females over 20 years old living in Ulsan and Gyungnam province. The data was analyzed by frequency, reliability, factor analysis, and structural equation model analysis. Findings showed that Chemyeon was shown to reduce customer' switching behavior. Also, three factors of relationship benefits(economic benefit, social·psychological benefit, and special treatment benefit) had negative effects on customer' switching behavior.

Dual Frequency Switchable Flexoelectric Cholesteric Devices

  • Chien, Liang-Chy;Shi, Lei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.105-108
    • /
    • 2005
  • We demonstrate an electro-optical device based on the flexoelectric effect of a short-pitched cholesteric liquid crystal. By using a dual-frequency switchable nematic, a small amount of chiral dopant and a small amount of phase-separated polymer localized on the surface, we were able to create a device that operates in amplitude (flexoelectric) and phase(dielectric) modes. At high frequency the dual frequency liquid crystal suppresses the phase mode at higher voltage, which improves the switching speed, and thereby preserving the in-plane-switching mode.

  • PDF

A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter (양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법)

  • Song, Y.J.;Park, S.I.;Jeong, H.G.;Han, S.B.;Jung, B.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF

Fast Context Switching Architecture in Embedded Systems (빠른 문맥전환을 위한 임베디드 시스템 구조)

  • Son, Jeongho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2010
  • In real-time embedded systems, the responsibility is the most important thing because it is related to human life. Context switching is a part of which can slow down the responsibility. We therefore should minimize the amount of state that needs to be saved during context switching. In this paper, we introduce a new architecture (Register Farm) for context switching which can exchange two contexts in one cycle time. Although it might increase the cost of MCU design and the complexity of circuit, it cannot miss any interrupt during context switching. Consequently, Register Farm architecture can make embedded systems spread out in human life because it can increase reliability and responsibility in real time embedded systems.

Development of Control Algorithms Considering the Effect of a Control Sampling Period on the Total Amount of Switching for a Switched System (컨트롤 샘플링 주기가 스위칭 시스템의 결합-분리 횟수에 미치는 영향을 고려한 제어 알고리듬 개발)

  • Joung, Jin-Wook;Chung, Lan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.67-76
    • /
    • 2009
  • Recently, the active interaction control (AIC) system was proposed as a semi-active control system. The AIC system consists of a primary structure and an auxiliary structure. The objective of the AIC system is to control the response of the primary structure through engagement and disengagement between the primary and auxiliary structures. Previous switching control algorithms have been shown to be effective in reducing the response of the primary structure. However, they have the main drawback of requiring an excessive engagement-disengagement frequency and high interaction force. In this paper, the regions in which the switching is activated and the regions in which the switching is deactivated are described separately, to effectively determine the engagement or the disengagement. The general relationship between the switching regions and the deactivated switching regions selected according to the engagement-disengagement conditions is described within the newly-developed comprehensive switching framework. The proposed engagement-disengagement conditions are designed within a comprehensive switching framework, to reduce engagement-disengagement frequency and interaction force. Furthermore, the effect of a control sampling period on the AIC system is explained in terms of the engagement-disengagement frequency. The effectiveness of the proposed algorithms and the effect of the control sampling period are considered for a single degree of freedom model under free vibration. It is observed that increasing the duration of stay by using a large control sampling period prevents the AIC system from activating the possible chance of switching. The proposed algorithms are shown to be effective, both in restricting ineffective switching and in reducing interaction force.

Applicable Method for Average Switching Loss Calculation in Power Electronic Converters

  • Hasari, Seyyed Abbas Saremi;Salemnia, Ahmad;Hamzeh, Mohsen
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1097-1108
    • /
    • 2017
  • Accurate calculation of the conduction and switching losses of a power electronic converter is required to achieve the efficiency of the converter. Such calculation is also useful for computing the junction temperature of the switches. A few models have been developed in the articles for calculating the switching energy losses during switching transitions for the given values of switched voltage and switched current. In this study, these models are comprehensively reviewed and investigated for the first time for ease of comparison among them. These models are used for calculating the average amount of switching power losses. However, some points and details should be considered in utilizing these models when switched current or switched voltage presents time-variant and alternative quantity. Therefore, an applicable technique is proposed in details to use these models under the above-mentioned conditions. A proper switching loss model and the presented technique are used to establish a new and fast method for obtaining the average switching power losses in any type of power electronic converters. The accuracy of the proposed method is evaluated by comprehensive simulation studies and experimental results.

Linerly Graded Encoder for High Resolution Angle Control of SRM Drive

  • Lee, Sang-Hun;Lim, Heon-Ho;Park, Sung-Jun;Ahn, Jin-Woo;Kim, Cheul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.185-192
    • /
    • 2001
  • In SRM drive, the ON·OFF angles of each phase switch should be accurately controlled in order to control the torque and speed stably. The accuracy of the switching angles is dependent upon the resolution of the encoder and the sampling period of the microprocessor, that are used to provide the information of the rotor position and to control the SRM power circuit, respectively. However, as the speed increases, the amount of the switching angle deviation from the preset values is also increased. Therefore, the low cost encoder suitable for the practical and stable SRM drive is proposed and the control algorithm to provide the switching signals using the simple digital logic circuit is also presented in this paper, As a result, a stable high speed SRM drive can be achieved by the high resolution switching angle control and it is verified from the experiments that the proposed encoder the logic controller can be a powerful candidate for the practical low cost SRM drive.

  • PDF

Bipolar Resistance Switching Characteristics of $NiO_{1+x}$ films with Adding Higher-Valence Impurities

  • Kim, Jong-Gi;Son, Hyeon-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.370-370
    • /
    • 2010
  • The effects of adding higher-valence impurities on the bipolar resistive switching characteristics of Pt/$NiO_{1+x}$/TiN MIM stacks and physical properties were investigated. $NiO_{1+x}$ films with 14% W deposited at 20% oxygen partial pressure exhibited the bipolar resistance switching characteristics in Pt/$NiO_{1+x}$/TiN MIM stacks, while $NiO_{1+x}$ films with 8.2% W show unipolar resistance switching behavior. The relationship of W-doping and the crystallinity was studied by X-ray diffraction. The metallic Ni contents and $WO_x$ binding states with W amount was investigated by XPS. Our result showed that the metallic Ni, $WO_x$ binding states, and crystallinity in $NiO_{1+x}$ played an important role on the bipolar resistive switching.

  • PDF

Improved Hysteresis Current Control Regulator for High-efficiency Switching (고효율 스위칭을 위한 개선된 히스테리시스 전류제어기)

  • Hong, Sun-Ki;Park, Jin-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1606-1610
    • /
    • 2012
  • Hysteresis current regulator has been used widely because of its simple principle and structure. However, when the current band width is too narrow or the applied voltage is relatively too high, the switching frequency may increase abruptly and it generates a large amount of heat. Thus, this study will suggest a better and simple method to reduce the switching frequency. For single phase current control, the proposed hysteresis current control is executed by adding 0 mode state and comparing the slope of the current reference. This simple method decreases the generated switching frequency and significantly reduces the generated heat. This proposed method was proved with simulations and experiments comparing with the classical hysteresis current control method.