• Title/Summary/Keyword: Amount of supply

Search Result 1,351, Processing Time 0.03 seconds

Seasonal Patterns of Sediment Supply to Coastal Foredune of Seungbong Island, Korea

  • Woo, Han-Jun;Seo, Jong-Chul;Kweon, Su-Jae;Je, Jong-Geel
    • Ocean and Polar Research
    • /
    • v.24 no.1
    • /
    • pp.39-45
    • /
    • 2002
  • The seasonal patterns of sediment supply were investigated during the period of June 1999 to June 2000 on a coastal foredune of Seungbong Island, Korea. Sediment supply was determined from measurements of geomorphic changes in the foredune and beach along six lines. Most sands were deposited on the dunefoot and foredune area during the winter and spring, from November to April. The largest amount of sands was deposited along the lines 5 and 6 near the sea-dike in the southern tip of the dune area. In general, the sand on the beach was gradually eroded in spring, summer and fall but deposited in winter. Total sediment accumulation over the study period was $484m^3$ for the foredune and $345m^3$ for the beach. The volume of the foredune increased in the winter and spring, whereas the volume of beach increased in the winter. Variation in sediment deposition appears to be controlled primarily by variations in the seasonal wind regime.

Family Restaurants' Manpower Program : An Application of Goal Programming (목표계획법을 활용한 패밀리레스토랑의 인력계획)

  • 박한나
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.16 no.2
    • /
    • pp.79-95
    • /
    • 2005
  • This study clarified the fact that the existing 'manpower supply and demand plans', preceding studies, theoretical researches of the past cannot satisfy the multi-goals of organizations, instead, the existing plans focused on only the number of customers and total amount of service. Next, a necessity of more proper manpower plans that consider comprehensive goals of the organizations is suggested then, this study tried to make the countermeasures. As for studying methods, a priority sequence in the organizations' manpower management's goals is set by AHP(Analytic Hierarchy Process), a business administrative scientific skill. Proper manpower policies of the food service enterprises, which satisfy the organizations' multi-goals, are established by GP(Goal Programming). Based on it, mid and short term 'manpower supply and demand plans' are established. For the purpose of increasing the study's efficiency, example studies are conducted in one family restaurant. The limit of this study is that inner personnel management details such as promotion, new personnel appointments, unemployment, retirement were not considerately considered. Therefore, the future studies should think over those limits and research the labor-force supply from the outside also.

  • PDF

A Study on the Spray and Combustion Characteristics of Direct-injection LPG (직접분사식 LPG의 분무 및 연소 특성에 관한 연구)

  • Hwang, Seong-Ill;Chung, Sung-Sik;Yeom, Jeong-Kuk
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.40-48
    • /
    • 2015
  • As advantages of LPG-DI engine, LPG is directly injected into combustion chamber during compression stroke to reduce compression temperature, prevent knock and spontaneous combustion, and adjust engine output using the amount of directly injected fuel, thereby reducing pumping loss caused by throttle valve. Stratified charge can be supplied nearby spark plugs to allow for overall lean combustion, which improves thermal efficiency and can cope with problems regarding emission regulations. In addition, it is characterized by free designing of intake manifold. Despite the fact that LPG-DI has many advantages as described above, there is lack of detailed investigation and study on spray characteristics, combustion flame characteristics, and ignition probability. In this study, a visualization experiment system that consists of visualization combustion chamber, air supply control system, emission control system, LPG fuel supply system, electronic control system and image data acquisition system was designed and manufactured. For supply of stratified charge in the combustion chamber, alignment of injector and spark plugs was made linear.

Estimated Advection Heat in the East/Japan Sea

  • Han, In-Seong;Kang, Yong-Q;Kim, Bok-Kee;Seong, Ki-Tack
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.165-170
    • /
    • 2003
  • A significant surface net heat loss appears around the Kuroshio and the Tsushima Warm Current regions. The area where the surface heat loss occurs should require heat to be supplied by the current to maintain the long-term annual heat balance. Oceanic heat advection in these regions plays an important role in the heat budget. The spatial distribution of the heat supply by the Tsushima Warm Current near the surface was examined by calculating the horizontal heat supply in the surface layer of the East/Japan Sea, directly from historical sea surface temperature and current data. We have also found a simple estimation of the effective vertical scale of heat supply by the current to compensate net heat loss using the heat supplied by the current in the surface 10m layer. The heat supplied by the current for the annual heat balance was large in the Korea/Tsushima Strait and along the Japanese Coast, and was small in the northwestern part of the East/Japan Sea. The amount of heat supplied by the current was large in the northwestern part and small in the southeastern part of the East/Japan Sea. These features suggest that the heat supplied by the Tsushima Warm Current is restricted to near the surface around the northeastern part and extends to a deeper layer around the southeastern part of the East/Japan Sea.

  • PDF

Reaction Characteristics of Rubbers and LPG fuels in LPLi Fuel Supply System (고무류 반응특성이 LPG액상공급시스템의 연료분사기 성능에 미치는 영향)

  • Kim, Chang-Up;Park, Cheol-Woong;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.94-100
    • /
    • 2007
  • The liquid phase LPG injection (LPLi) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type (the second generation technology) fuel supply system. To investigate the characteristics of LPG residue in liquid phase LPG injection system, various rubbers in LPG fuel system were reacted with LPG fuels during 3 months. The experimental results showed that the residue of a cover rubber in a fuel pump after test increased 10 times higher than that before test. Furthermore, the amount of sulfur, nitrogen species which are considered as main sources in deposit formation in the LPLi fuel injector were also found to be higher than that in original LPG fuel. And rubber properties of fuel pump cover were decreased after reaction test compared with those of the original rubber. Therefore, the rubber for fuel pump cover is not suitable for a proper material in LPLi fuel system. And these results can provide more information if a motor company shares the data of core rubber parts in field test LPLi vehicles.

  • PDF

Generator's Maintenance Scheduling to Improve Supply Reliability (공급신뢰도 개선을 위한 발전기 보수계획)

  • 차준민
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.89-95
    • /
    • 1998
  • Maintenance scheduling of generators plays an important role in evaluating supply reliability of power systems. Since generators must be maintained and inspected, the generation planner must schedule planned outages during the year. Several factors entering into this scheduling analysis include: seasonal load-demand profile, amount of maintenance, size of the units, elapsed time from last maintenance, and availability of maintenance crew. This paper proposes a new maintenance scheduling algorithm for the alternatives of long-term generation expansion planning by using LOLP levelization method which is known as an effective method for the generator's maintenance scheduling. To get the best supply reliability of power systems, we change the maintenance period to levelize the reliability over all period. The proposed algorithm is applied to a real size power system and the better reliability results are obtained.

  • PDF

Development of Titanium Metal Surface Anodizing Equipment (티타늄 금속 표면 양극산화장치 개발)

  • Yang, Keun-Ho;Min, Byung-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1307-1312
    • /
    • 2013
  • In this paper, alkaline or acidic solution, in particular the principle of electrolysis to oxidize the metal surface to form a device isolation film is developed. In the past, mainly in the form of pulse voltage is applied to the anode only a unipolar method, but in this paper by using the H-bridge to the amount of the positive (+) voltage and the negative supply voltage, alternating voltage polarity devices were fabricated according to the characteristics of metal specimens with different electrical conditions to form an oxide film on the device was developed. Supply current variable was used for the PWM modulation, (+) and (-) polarity change of the H-bridge bipolar pulse voltage to supply the was that. As a result, a more uniform pores with unipolar film was formed.

Assessment of Adequacy of Urban Water Supply (도시 상수도 공급량 산정의 적정성 평가)

  • Kim, Jang Jin;Chang, Hyung Joon;Lee, Ho Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.4
    • /
    • pp.61-67
    • /
    • 2021
  • In this study, the adequacy of water supply critical factors of urban design was examined. The supply of water supply is analyzed in various ways as the design progresses. Starting with basic data collection and analysis a supply and demand plan is established to calculate the amount of water supply and in this study the adequacy of population estimation and original unit calculation was evaluated. Among the second new cities where actual data can be secured Wirye New Town was selected as the study target area. Related data were analyzed to confirm the future population and the original unit and compared with the measured data. As of September 2020, the population of Wirye New Town was 93,977, showing the appropriateness of about 84% with a planned population of 110,990 confirming that the planned population and the actual population were almost similar. In the case of the original unit, it was calculated as 314 liters per person in Seoul and 320 liters per person in Seongnam at the time of design. As a result, it was found that there was some agreement in the population estimation while examining the supply in the planned city. In the case of Korea, there is a lot of interest in revitalizing the existing city, away from continuous development. Therefore it is judged that there is a need for further research on the adequacy of supply for the old city center.

Estimated Food Cost to Maintain Basic Living Expenditure (기본생계비를 위한 식품비 산정에 관한 연구)

  • Mun, Hyeon-Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.4 no.2
    • /
    • pp.245-253
    • /
    • 1998
  • In this study, the food cost for the urban worker's living expenses was estimated for the Korea Labor Union. The urban workers living expenses are minimum of healthy and decency level expenses with allowances for minimum quality of life. Thus, the food cost should be enough for purchasing proper kinds and amount of foods which can supply sufficient nutrient to maintain health and which should reflect current food consumption patterns. To estimate the food cost, the Korean Recommended Dietary Allowances was used to calculate the amount of nutrients which should be supplied. The National nutrition survey and the Food balance sheet, were used to estimate the current consumption patterns for the kind and amount of food. To estimate price for each food item, the market survey was executed in six large cities. Also, to verify the estimated food cost, actual food costs were surveyed. For 5 kinds of model household, dietary allowances were calculated for the each nutrient. Using the Korean food guides, the number of serving for each food group were decided for the model households. In each food group, the amount and kind of foods were decided by the current food consumption pattern. The kind and amount of food were adjusted by the amount of calculated nutrient. When the amount of nutrient was between 90% and 110% of the recommended dietary intake, it was accepted. With these amount and kinds of foods, the food cost were calculated using the market survey. Considering extra expenses for the eating-out and processed foods, extra expenses are added. As a results, for single person family, the estimated food cost was 149,210won per month. For two, three, four and five person family, the estimated food costs were 245,179won, 381,182won, 501,669won and 687,980won per month, respectively. The estimated food cost were lower in the single and two person family than the actual food cost by the survey. The cost for eating-out gave major differences. In the future, to estimate food cost, the food consumption patterns for the different kind of household, sex and age should be studied carefully. Also, the pattern of eating-out should by analyzed.

  • PDF

Low Temperature Methane Steam Reforming for Hydrogen Production for Fuel Cells

  • Roh, Hyun-Seog;Jun, Ki-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.153-156
    • /
    • 2009
  • Low temperature methane steam reforming to produce $H_2$ for fuel cells has been calculated thermodynamically considering both heat loss of the reformer and unreacted $H_2$ in fuel cell stack. According to the thermodynamic equilibrium analysis, it is possible to operate methane steam reforming at low temperatures. A scheme for the low temperature methane steam reforming to produce $H_2$ for fuel cells by burning both unconverted $CH_4$ and $H_2$ to supply the heat for steam methane reforming has been proposed. The calculated value of the heat balance temperature is strongly dependent upon the amount of unreacted $H_2$ and heat loss of the reformer. If unreacted $H_2$ increases, less methane is required because unreacted $H_2$ can be burned to supply the heat. As a consequence, it is suitable to increase the reaction temperature for getting higher $CH_4$ conversion and more $H_2$ for fuel cell stack. If heat loss increases from the reformer, it is necessary to supply more heat for the endothermic methane steam reforming reaction from burning unconverted $CH_4$, resulting in decreasing the reforming temperature. Experimentally, it has been confirmed that low temperature methane steam reforming is possible with stable activity.