• Title/Summary/Keyword: All Ceramic

Search Result 1,133, Processing Time 0.036 seconds

An in-vitro wear study of human enamel opposing heat-pressed ceramics (2종의 열가압 도재와 법랑질 간의 마모에 관한 연구)

  • Park, Chan-Yong;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the wear characteristics of human enamel opposing 2 heat-pressed ceramics (e.max Press and Empress Esthetic), conventional feldspathic porcelain (Ceramco 3) and type III gold alloy. Material and methods: Intact cusps of extracted premolars were used for enamel specimens. Five disk samples were made for each of two heat-pressed ceramics groups, conventional feldspathic porcelain group and type III gold alloy group. Wear tests were conducted in distilled water using a pin-on-disk tribometer. The amount of enamel wear was determined by weighing the enamel specimens before and after wear tests, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear characteristics. Results: 1. Ceramco 3 led to the greatest amount of enamel wear followed by Empress Esthetic, e.max Press and type III gold alloy. However, there was no significant difference between Ceramco 3 and Empress Esthetic (P>.05), and there were also no significant differences among Empress Esthetic, e.max Press and type III gold alloy (P>.05). 2. The average surface roughness of e.max Press after wear test was smallest followed by Empress Esthetic and Ceramco 3, but there was no significant difference between Empress Esthetic and Ceramco 3 (P>.05). 3. There were no significant differences among the depth of wear tracks of all the groups (P>.05). The group that showed the largest width of wear track was Ceramco 3 followed by Empress Esthetic, e.max Press and type III gold alloy. However, there was no significant difference between e.max Press and Empress Esthetic (P>.05), and there was also no significant difference between Empress Esthetic and Ceramco 3 (P>.05). Conclusion: Within the limits of this study, heat-pressed ceramics were not more abrasive than conventional feldspathic porcelain.

An Comparison of Storability of Several Cultivars Chicon Grown in Different Regions (품종과 재배지역에 따른 치콘의 저장성 비교)

  • Kang, Ho-Min;Kim, Hyuk-Su;Seo, Hyun-Taek;Won, Jae-Hee
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.291-296
    • /
    • 2009
  • This study was conducted to compare the storability of 6 chicory cultivars for producing chicon; 'Vintor', 'Focus', 'Metafora', 'Kibora', 'Nobus', and 'Redoria Red' grown in 2 regions: Chuncheon (plain region) and Pyeongchang (high land region). Chicons were produced from chicory roots that grown for 120days and then stored for over 120days at $2^{\circ}C$ and 90% of RH conditions. To produce chicon, chicory root was forced at $18^{\circ}C$ for 22days with suppling the nutrient solution ($KNO_30.54g{\cdot}L^{-1}$, $Ca(NO_3)_2\;1.02g{\cdot}L^{-1}$, $MgSO_4\;0.36g{\cdot}L^{-1}$, $KH_2PO_4\;0.21g{\cdot}L^{-1}$, $K_2SO_4\;0.10g{\cdot}L^{-1}$, pH 7.0). Chicons produced from 6 different chicory cultivars packed with $25{\mu}m$ ceramic film and stored for 25days at $8^{\circ}C$. The fresh weight of chicon in MAP was maintained to 99.5% of pre-storage weight. The fresh weight of 'Redoria Red' was lowest in all cultivars, and that of Chuncheon region cultivated treatment was lower than Pyeongchang treatment. The $CO_2$ and $O_2$ concentration in chicon MAP were 2% and $10{\sim}17%$. There were not significantly different among cultivars and between regions, although 'Redoria Red' cultivar showed highest $CO_2$ and lowest $O_2$ concentrations. The ethylene concentration in chicon MAP was $1.0{\mu}{\iota}{\cdot}{\iota}^{-1}$ and also didn't show any significant difference among all treatments. Chicon detoriorated visual quality with appearing russet spotting that result from ethylene gas. The visual quality of 'Redoria Red' cultivar decreased faster than the other cultivars. 'Metafora', 'Focus', and 'Kibora' maintained higher firmness of their leaf than the others, and the firmness was higher grown in Pyeongchang region cultivated treatments than in Chuncheon region.

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Study on Acknowledge and State of Clinical Experience for 3-years Dental Technology Department (3년제 치기공과 임상실습에 대한 인식 및 실태조사 - 일부 치과기공소 소장을 중심으로 -)

  • Park, Myung-Ja
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.41-57
    • /
    • 1995
  • This study was conducted to collect and analyze previous information in order to manage efficience, improve experience effect and promote employment rate. The questionnaire interview with 27 chief of dental Laboratory refered clinical experience in technology department about clinical experience in 14 Jumior colleges were also investigated. The results were summarried as follows : The portion of age of 35-39 among chief of dental Laboratory was 40.7% which was the highest, that of male was 96.3%, that of junior college graduate was 97.5%, that of 10years experience was 92.6% and that of ceramic technician was 85.2%, 63.0% dental laboratory for clinical experience was a bore space of 30pyong. Aspect of dental laboratory management, manufacturing all part of prosthetic restoration was 29.6%, othodontic appliance and ceramic restoration was 7.4%, 3.8%, each. The percentage of 40.7 was having connection with 30-3a dental clinics and referring case per day was 10-19 cases(40.7%), manufacturing time of referred prosthetic restoration was 3-4 days(77.8%), places preparing seminar room for education was 29.6%, above a place of 40pyong was 11.1% 30-34 pyong and 35-39 pyong was 7.4% each. During training of 2 years education course student, 18.5% was rack of thorough occupational career. While 44.4% will want the more salary among 3years education course student, 74.1% will expect the more dental techmicians would engaged in their field, 51.9% will hope improve of their theory and practice, 29.6% be expected better skill and 14.8% be expected better theory. Attitude of clinical experience places was distributed by 59.3% of offering only experience chance, 25.9% of wasting time and 29.0% of annoying. The big emphasis of climical experience was thorough occupational career(44.4%). The clinical experience places of our college were selected after direct visiting, so their condition of management was not that bad but most of dental laboratory were poor in management state and working environment. Therefore it is difficult to choose appropriate places and dental Laboratory are also limited manpower and time as suppliers. So that it recommended to induce flexible management of experience period by interval and rotation of experience places among college and to applicate intern-system for employment ant industry-college cooperation aspect.

  • PDF

The study on the entry of dental technicians in the public health center for a manpower supply and demand plane (Centering around a denture insurance policy in 2012) (인력수급 대책을 위한 치과기공사의 보건지소 진출에 관한 연구 - 2012년 틀니보험화 정책을 중심으로 -)

  • Lee, Jong-Do;Kim, Jeong-Sook;Park, Kwang-Sig
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.417-433
    • /
    • 2010
  • Purpose: This study evaluated the manpower planning of dental technicians. Methods: Methods : Survey was conducted regarding subject's general characteristics, characteristics of dental technician's occupational view and working conditions, and reason to enter into branches of the public health enter. The survey sample consisted of 323 dental technicians (221 male/ 102 female). Survey was conducted for one month from August 1 to September 1 in 2010. Following results were obtained. Results: 1. Regarding general characteristics of the subjects, there was a slight male predilection with 68.4%. Subjects in their 40s occupied the highest proportion of 32.2%. Majority of subjects worked in the big cities (71.5%). Favored working places were dental laboratory (57.6%) and dental hospital or dental clinic (19.5%). Although no position is available in the public sector such as public health center or health care civil servant, 9.3% preferred working in the public health center. Public sector is more favored than 2-year technical colleges or dental supply and equipment companies. In respect to education, 57% of the subjects graduated college. 67.8% were married. Subjects who specialize in the porcelain or all-ceramic were 57.9%. With regard to current position, head of the dental laboratory was most common. 2. Following occupation characteristics were found. Economic reason took the highest proportion when deciding their occupation (39.9%) followed by gaining social experience (36.5%). Majority of the subjects (76.5%) wanted to work as dental technicians until their retirement. 71.5% pursuit to become a manager of the dental laboratory. 76.1% agreed on opening a dental technician position in the public health center. Regarding an authority to lead developing the dental technician position in the public sector, majority of the subject chose ministry of health and welfare (35.6%) and Korean dental technologist association (34.7%). Employment (average, 30%) and turnover rate (average, 36.5%) of dental technology college graduates ranged from 40% to 60%. Most important factors for the employment were practical experience (41.2%) and competency (34.4%). With regard to job satisfaction, so-so as 46.7% and satisfactory was 42.7% 3. In respect to the reason for opening a position in the public health center, 'It is needed to continue denture rogram for elderly patients' obtained the highest score (4.14 point). 'Institutional devices are required to open a position for dental technicians as a public healthcare provider' received high score (4.11 point). 4. Concerning the working conditions, 'professional knowledge is required' received the highest score (4.23) followed by 'too short maternity and parental leave' (4.21). 5. Relationship between general characteristics of the subjects and favor of working in the public health center was investigated. Significant differences were found according to the current and favored working area, favored occupation, education level, marital status, and specialty. Working in the public health center was favored by following subjects: working in mid- or small-sized cities (4.16 point, p<0.05); PhD degree-holder (4.59 point, p<0.01). 6. Among general characteristics of the subjects, significant difference of working conditions was found in the following factors: gender; working areas; favored working areas; favored working positions, and education level. Majority of subjects favored working in big cities and currently work in big cities although satisfaction was comparatively low (3.75 score). 7. Future plan to work in public health center was evaluated according to occupational characteristics. Subject's intention to work in the public healthcare center was significantly affected by opening of dental technician position, leading authority, average turnover rate, and factors affecting employment. Working in the public health care center was favored by the following subjects: Dental technicians who actively supported opening of the dental technician position (4.34 point, p<0.001); subjects who thought the Korean dental technologist association is responsible for the opening of positions in the public sector (4.26 point, p<0.001); and subjects who thought that attitude and character are important for the employment (p<0.001). 8. Concerning difference of working conditions according to the occupational characteristics, significant difference was demonstrated by factors such as a reason to choose to be a dental technician, work plan, pursuing position, responsible authority, average employment rate, and job satisfaction. High standard of working conditions was required in subjects who selected to be a dental technician for the leisure time after work (s.05 point, p<0.01), who planted to work until their marriage (4.25 point, p<0.001), and who pursuit to be a manager (3.98, p<0.05). 9. In respect to influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.068 and age affected the working condition with significant difference according to the pvalue. 10. Regarding influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.335 and work plan, opening of dental technician position in the public sector, and responsible authority had significant influence over the subject's intention to work in the public health center according to the p-value. 11. With regard to the influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.091 and reason to choose to be a dental technician, work plan, and responsible authority significantly affected subject's working conditions. Conclusion: Korean society is becoming a super-aged society according to several statistics. As aged population is rapidly increasing, national health insurance plans to cover denture for senior citizen over 75 years old from 2012. Therefore, dental technicians are urgently needed in the public health centers all over the nation. Many subjects in this study planed to work until their retirement and recognized dental technician's expertise. Ministry of health and welfare and Korean dental technologist association should co-operate each other to prepare foundation and institutional devices for dental technicians to advance into the public health center. This will improve oral health of the population. This study showed urgency of medical facilities and services which meets increasing number of aged population and welfare of the population.

Comparison Study of Water Tension and Content Characteristics in Differently Textured Soils under Automatic Drip Irrigation (자동점적관수에 의한 토성별 수분함량 및 장력 변화특성 비교 연구)

  • Kim, Hak-Jin;Ahn, Sung-Wuk;Han, Kyung-Hwa;Choi, Jin-Yong;Chung, Sun-Ok;Roh, Mi-Young;Hur, Seung-Oh
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.341-348
    • /
    • 2013
  • Maintenance of adequate soil tension or content during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil tension and content for precision irrigation would allow optimal soil water condition to crops and minimize the adverse effects of water stress on crop growth and development. This research reports on a comparison of soil water tension and content variations in differently textured soils over time under drip irrigation using two different water management methods, i.e. pulse time and required water irrigation methods. The pulse time-based irrigation was performed by turning the solenoid valve on and off for preset times to allow the wetting front to disperse in root zone before additional water was applied. The required water estimation method was a new water control logic designed by Rural Development Administration that applies the amount of water required based on a conversion of the measured water tension into water content. The use of the pulse time irrigation method under drip irrigation at a high tension of -20 kPa and high temperatures over $30^{\circ}C$ was not successful at maintaining moisture tensions within an appropriate range of 5 kPa because the preset irrigation times used for water control could not compensate for the change in evapotranspiration during day and night. The response time and pattern of water contents for all of the tested soils measured with capacitance-based sensor probes were faster and more direct than those of water tensions measured with porous and ceramic cup-based tensiometers when water was applied, indicating water content would be a better control variable for automatic irrigation. The required water estimation-based irrigation method provided relatively stable control of moisture tension, even though somewhat lower tension values were obtained as compared to the target tension of -20 kPa, indicating that growers could expect to be effective in controlling low tensions ranging from -10 to -20 kPa with the required water estimation system.

Synthesis and Phase Relations of Potassium-Beta-Aluminas in the Ternary System K2O-MgO-Al2O3 (K2O-MgO-Al2O3 3성분계에서 K+-β/β"-Al2O3의 합성 및 상관계)

  • Ham, Choul-Hwan;Lim, Sung-Ki;Lee, Chung-Kee;Yoo, Seung-Eul
    • Applied Chemistry for Engineering
    • /
    • v.10 no.7
    • /
    • pp.1086-1091
    • /
    • 1999
  • $K^+-{\beta}/{\beta}"-Al_2O_3$ in the ternary system $K_2O-MgO-Al_2O_3$ was directly synthesized by solid state reaction. The phase formation and phase relation were carefully investigated in relation to starting composition, calcining temperature and time, and dispersion medium. The optimal synthetic condition was also examined for the formation of ${\beta}"-Al_2O_3$ phase with a maximum fraction. As a composition range, the mole ratio of $K_2O$ to $Al_2O_3$ was changed from 1:5 to 1:6.2 and the amount of MgO used as a stabilizer was varied from 4.2 wt % to 6.3 wt %. The calcining temperature was selected between $1000^{\circ}C$ and $1500^{\circ}C$. At $1000^{\circ}C$, the ${\beta}/{\beta}"-Al_2O_3$ phases began to form resulted from the combining of ${\alpha}-Al_2O_3$ and $KAlO_2$ and increased with temperature rising. All of ${\alpha}-Al_2O_3$ phase disappeared to be homogenized to the ${\beta}/{\beta}"-Al_2O_3$ phase at $1200^{\circ}C$. Near the temperature at $1300^{\circ}C$, the fraction of ${\beta}"-Al_2O_3$ phase showed a maximum value with the composition of $K_{1.67}Mg_{0.67}Al_{10.33}O_{17}$. At temperatures above $1300^{\circ}C$, the fraction of ${\beta}"-Al_2O_3$ phase decreased gradually owing to $K_2O$ loss caused by a high potassium vapor pressure, and the appropriate calcining time was about 5 hours. Acetone was more effective than distilled water as a dispersion medium for milling and mixing.

  • PDF

Effects of Active Modified Atmosphere Packaging on the Storability of Fresh-cut Paprika (Active MAP가 파프리카 신선편이 저장성에 미치는 영향)

  • Choi, In-Lee;Yoo, Tae-Jong;Jung, Hyun-Jin;Kim, Il-Seop;Kang, Ho-Min;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.227-232
    • /
    • 2011
  • The processing techniques are need to use the non-marketable paprika fruit because paprika that is difficult crop for cultivation and produced easily non-marketable fruits, such as physiological disorder fruit, malformed fruit, and small size fruit. This study was carried out to investigate the proper active modified atmosphere packaging (MAP) condition for enhancing the storability of fresh-cut paprika fruit. The fresh-cut paprika (cv 'Score', seminis) put into $7cm{\times}0.7cm$ size and packed them in 20 g bags. The active MAP and vacuum treated paprika fruits were packaged with LLDPE/Nylon, EVOH, Tie film, and injected partial pressures of $CO_2$ and $O_2$, and $N_2$ in the packages immediately after sealing to treat active MAP. The ratio of $CO_2$, $O_2$, and $N_2$ of active MAP conditions were 0 : 20 : 80 (air), 5 : 5 : 90, 30 : 10 : 60, 10 : 70 : 20 and vacuum treatment did not contain any gas. The passive packaging treated paprika packaged with $40{\mu}m$ ceramic film. After 7 days of storage at $9^{\circ}C$, the fresh weight decreased less than 2% in all treatments, and showed lower in 5 : 5 : 90 ($CO_2:O_2:N_2$) active-MAP treatment and higher in vacuum treatment than other treatments. The $CO_2$ and $O_2$ concentration in packages did not change remarkably in active-MA treatments except 30 : 10 : 60 active-MAP treatment that showed sharply decreased $O_2$, concentration and increased $CO_2$ concentration at $1^{st}$ day of storage at $9^{\circ}C$. The ethylene concentration in package was the highest in 30 : 10 : 60 active-MAP treatment and the lowest in the passive MAP treatment that packaged with gas permeable film during $9^{\circ}C$ storage for 7 days. The 30 : 10 : 60 active-MAP treatments were not proper condition to storage fresh-cut paprika. The visual quality was maintained higher in 0 : 20 : 80 (air), 5 : 5 : 90, and 10 : 70 : 20 active MAP treatments and passive MAP treatment than others and the firmness, off-odor, and electrolyte leakage was investigated at 7th day of storage at $9^{\circ}C$. The 5 : 5 : 90 and 10 : 70 : 20 active-MAP treatment showed higher firmness and lower off-odor than other treatments after $7^{th}$ day of storage at $9^{\circ}C$. In addition, the electrolyte leakage was reduced less than 20% at 0 : 20 : 80 (air), 5 : 5 : 90, 10 : 70 : 20, and passive MA treatments. Therefore, 10 : 70 : 20 ($CO_2:O_2:N_2$) and 0 : 20 : 80 (air) might be recommended for proper active MAP conditions.

Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea (국내 시판되는 16가지 연무기/압축기의 성능 평가)

  • Kim, Hyun Jung;Lee, Cho Ae;Hwang, Eun Kyung;Han, Man Young;Ann, Uk Sung;Cho, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1235-1241
    • /
    • 2003
  • Purpose : We assessed the dynamic characteristics of 16 nebulizer/compressor combinations currently available in Korea. Methods : The 16 nebulizer/compressor combinations(Pariboy Type 38/Long life, Pariboy Type N/Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie 2/Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, Chang Woo ASI-Pro/Medel jet pulse) were evaluated in terms of particle size and mass output. In addition, we determined the effects of nebulizer fill volume on mass output. Results : Pariboy Type N/Long life has the highest respirable mass of 0.184 mg/min and Mesmed Neb-300/Own has the lowest 0.019 mg/min. Pariboy Type N/Long life has the highest mass output of 0.68 mg/min and the shortest mass median aerodynamic diameter(MMAD) of $3.76{\mu}m$. All combinations other than Pariboy Type N/Long life produced a MMAD of over $5{\mu}m$. MMAD over a 5 min nebulization ranged 3.76 to $9.83{\mu}m$. There were no significant effects of fill volume on mass output. Conclusion : We concluded that there is a wide variation in performance of nebulizer/compressor combinations. The characteristics of nebulizer/compressor combinations should be considered in selecting products.