• Title/Summary/Keyword: Alignment mechanism

Search Result 154, Processing Time 0.02 seconds

Failure Mechanism and Test Method for Reliability Standardization of Solder Joints (솔더조인트의 신뢰성 표준화를 위한 취성파괴 메커니즘 및 평가법 연구)

  • Kim, Kang-Dong;Huh, Seok-Hwan;Jang, Joong-Soon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.85-90
    • /
    • 2011
  • With regard to reliability of solder joint, the significant failures include open defects that occurs from alignment problem, Head in Pillow by PCB's warpage, the crack of solder by CTE mismatch, and the crack of IMC layer by mechanical impact. Especially as PCB down-sizing and surface finish is under progress, brittle failure of IMC layer between solder bump and PCB pad becomes a big issue. Therefore, it requires enhancing the level of difficulty in the existing assessment method and improving the measurement through the study on the mechanism of IMC formation, growth and brittle failure. Under this circumstance, this study is intended to suggest the direction of research for improving the reliability on the crack such as improvement of IMC brittle fracture.

Mechanism of Orientation of Liquid Crystal Molecules for Polarized UV-exposed Polyimide Alignment Layers (폴리애미드 배향막의 편광 자외선 조사에 따른 액정 배향 메카니즘)

  • 김일형;김욱수;하기룡
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.209-217
    • /
    • 2002
  • We studied the mechanism of orientation of polyimide molecules which were irradiated by polarized UU (PUV) using polarized Fourier transform infrared (FT-IR) spectroscopy and ultraviolet (UV) spectroscopy, According to the measured UV spectra, we found PI films mainly absorb UV light less than 350 nm wavelength, therefore, UV light less than 360 nm induces photochemical reaction of PI. PUV irradiation of PI films caused decrease of all peak intensities in the FT-IR spectra. except the newly formed broad peak at $3244 cm^{-1}$, due to degradation of the PI molecules. The remaining PI molecules after photo-degradation showed predominantly perpendicular molecular orientation to the irradiated PUV polarization direction, due to the preferential degradation of PI molecules parallel to irradiated PUV polarization direction. However the rubbing of PI films induced reorientation of the PI molecules parallel to the rubbing direction. We also investigated the alignment of the liquid crystal by rubbing or PUV irradiation. Liquid crystals align perpendicular to the PUV polarization direction and parallel to the rubbing direction.

Physicochemical Characteristics of UV/Ozone Treated Polydimethylsiloxane(PDMS) Wrinkle Structures (UV/Ozone 처리를 통한 Polydimethylsiloxane(PDMS) 주름 구조의 물리화학적 특성 분석)

  • Park, Hong-Gyu;Park, Seung-Yub
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.5
    • /
    • pp.321-327
    • /
    • 2022
  • In this paper, a wrinkled structure was formed on the PDMS surface through UV/Ozone treatment, and the wrinkle structure formation mechanism was revealed through physicochemical characterization. A wrinkle structure was formed on the PDMS surface through UV/Ozone treatment for 30 min, and periodic wrinkle formation on the PDMS surface was confirmed by cross-sectional imaging of the scanning electron microscope. In addition, through x-ray photoelectron spectroscopy spectral analysis, it was confirmed that the silica-like-surface of SiOx on the PDMS surface was formed by UV/Ozone. The results of this study not only improve the understanding of the mechanism of wrinkle structure formation on the PDMS surface by UV/Ozone treatment, but also can be used as a basic study to adjust the amplitude and period of the wrinkle structure according to UV/Ozone irradiation conditions in the future.contact angles and the surface energies of FSAMs, it was confirmed that pretilt angles of LC molecules increased according to the alkyl chain length. High optical transparency and uniform homeotropic LC alignment characteristics of FSAMs showed the possibility of FSAMs as an LC alignment layers.

IGRINS : Collimating Mirror Mount Opto-mechanical Design

  • Rukdee, Surangkhana;Park, Chan;Chun, Moo-Young;Yuk, In-Soo;Lee, Sung-Ho;Lee, Han-Shin;Kim, Kang-Min;Jeong, Hwa-Kyung;Strubhar, Joseph;Jaffe, Daniel T.
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.30.4-31
    • /
    • 2011
  • The Korea Astronomy and Space Science Institute (KASI) and the Department of Astronomy at the University of Texas at Austin (UT) are developing a near infrared wide-band high resolution spectrograph, IGRINS (Immersion Grating Infrared Spectrograph). The white-pupil design of the instrument optics uses 7 cryogenic mirrors including 3 aspherical off-axis collimators and 4 flat fold mirrors. Two of the 3 collimators are H- and K-band pupil transfer mirrors and they are designed as compensators for the system alignment in each channel. Therefore, their mount design will be one of the most sensitive parts in the IGRINS optomechanical system. The design work will include the computer-aided 3D modeling and finite element analysis (FEA) to optimize the structural stability of the mount models. The mount body will also include a tip-tilt and translation adjustment mechanism to be used as the alignment compensators.

  • PDF

Manufacturing of Micro-needle Using Micro-EDM Process (마이크로 EDM공정을 이용한 마이크로 바늘의 제조)

  • Lee, Choon-Mee;Kwon, Won Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.285-291
    • /
    • 2017
  • Micro-needles are used as transferring devices for sampling of tiny constitute substances from biological bodies. Typically, nickel is used as a coating to improve the rigidity of micro-needles. This study introduces the methodology to manufacture a WC needle with very high hardness and toughness. Micro-EDM technology was used to manufacture micro-needles with holes $130{\mu}m$ in diameter and $2300{\mu}m$ in length. A micro-needle was aligned to the micro-EDM electrode using a custom two degree-of-freedom alignment system. A three-step manufacturing technique was developed to drill a micro-hole using a WC electrode. In the first process, an electrode $105{\mu}m$ in diameter was used to make a hole. Electrodes of 90 and $105{\mu}m$ diameters were used in the second and third process, respectively. Consequently, a WC micro-needle with an inner hole of $135{\mu}m$ diameter, length of $2300{\mu}m$, and outer diameter of $300{\mu}m$ was developed.

A Proton Beam Shaping using an Extreme Aspect Ratio Micro-hole (극대세장비 마이크로 홀을 이용한 양성자 빔 집적 응용)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Seong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.737-744
    • /
    • 2012
  • EDM is the manufacturing process that uses the thermal energy to machine electrically conductive part. Despite a lot of research has been conducted for decades, the best aspect ratio of the micro hole using micro-EDM has not been over 30, yet. In the present study, new fabrication scheme was introduced to increase the aspect ratio of micro hole dramatically. Micro holes with less than 10 aspect ratio were aligned and welded together to manufacture a micro hole with extreme aspect ratio. Alignment of the micro hole with over 380 aspect ratio was conducted by the home-made apparatus installed with microscope and laser beam. The micro hole with extreme aspect ratio was used to shape pencil beam from proton beam generated from MC-50 cyclotron. The pencil beam was utilized to machine test specimen whose result was compared with GEANT4 computer simulation. It was shown that the experimental and simulation result were closer as the aspect ratio of the micro hole was bigger.

Narrative Review of Clinical Impact of Head-Hip Offset Following Adult Spinal Deformity Surgery

  • Sunho Kim;Seung-Jae Hyun;Jae-Koo Lee;Ki-Jeong Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.2
    • /
    • pp.137-145
    • /
    • 2024
  • In adult spinal deformity (ASD) surgery, mechanical failure (MF) has been a significant concern for spine surgeons as well as patients. Despite earnest endeavors to prevent MF, the absence of a definitive consensus persists, owing to the intricate interplay of multifarious factors associated with this complication. Previous approaches centered around global spinal alignment have yielded limited success in entirely forestalling MF. These methodologies, albeit valuable, exhibited limitations by neglecting to encompass global balance and compensatory mechanisms within their purview. In response to this concern, an in-depth comprehension of global balance and compensatory mechanisms emerges as imperative. In this discourse, the center of gravity and the gravity line are gaining attention in recent investigations pertaining to global balance. This narrative review aims to provide an overview of the global balance and a comprehensive understanding of related concepts and knowledge. Moreover, it delves into the clinical ramifications of the contemporary optimal correction paradigm to furnish an encompassing understanding of global balance and the current optimal correction strategies within the context of ASD surgery. By doing so, it endeavors to furnish spine surgeons with a guiding compass, enriching their decision-making process as they navigate the intricate terrain of ASD surgical interventions.

A study on real time inspection of OLED protective film using edge detecting algorithm (Edge Detecting Algorithm을 이용한 OLED 보호 필름의 Real Time Inspection에 대한 연구)

  • Han, Joo-Seok;Han, Bong-Seok;Han, Yu-Jin;Choi, Doo-Sun;Kim, Tae-Min;Ko, Kang-Ho;Park, Jung-Rae;Lim, Dong-Wook
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.14-20
    • /
    • 2020
  • In OLED panel production process, it is necessary to cut a part of protective film as a preprocess for lighting inspection. The current method is to recognize only the fiducial mark of the cut-out panel. Bare Glass Cutting does not compensate for machining cumulative tolerances. Even though process defects still occur, it is necessary to develop technology to solve this problem because only the Align Mark of the panel that has already been cut is used as the reference point for alignment. There is a lot of defective lighting during panel lighting test because the correct protective film is not cut on the panel power and signal application pad position. In laser cutting process to remove the polarizing film / protective film / TSP film of OLED panel, laser processing is not performed immediately after the panel alignment based on the alignment mark only. Therefore, in this paper, we performed real time inspection which minimizes the mechanism tolerance by correcting the laser cutting path of the protective film in real time using Machine Vision. We have studied calibration algorithm of Vision Software coordinate system and real image coordinate system to minimize inspection resolution and position detection error and edge detection algorithm to accurately measure edge of panel.

Study of Properties of HfO2 thin film for Low Power Mobile Information Device (저전력 휴대용 통신단말을 위한 이온빔 처리된 HfO2 박막의 특성 연구)

  • Kim, Won Bae;Lee, Ho Young
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.89-93
    • /
    • 2015
  • Ion-beam irradiation(IB) on $HfO_2$ surface induced high-performance liquidcrystal(LC) driving at a 1-V threshold with vertical alignment of liquid crystals(LC). The high-k materials Atomic layer deposition was used to obtain LC orientation on ultrathin and high-quality films of $HfO_2$ layers. To analyze surface morphological transition of $HfO_2$ which can act as physical alignment effect of LC, atomic force microscopy images are employed with various IB intensities. The contact angle was measured to elucidate the mechanism of vertical alignment of LC on $HfO_2$ with IB irradiation. Contact angle measurement show the surface energy changes via IB intensity increasing.

Comparison of Glenohumeral Stabilization Exercise and Scapular Stabilization Exercise on Upper Extremity Stability, Alignment, Pain, Muscle Power and Range of Motion in Patients With Nonspecific Shoulder Pain

  • Jeon, Na-young;Chon, Seung-chul
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.38-46
    • /
    • 2016
  • Background: Shoulder stabilization commonly involves two components: the glenohumeral stabilization exercise (GSE) and scapular stabilization exercise (SSE). Despite the fact that the shoulder stabilization has advantageous merit, to our knowledge, only a few studies have compared the superior of the GSE and the SSE. Objects: The purpose of this study was to assess the effects of GSE in patients with nonspecific shoulder pain. Methods: Thirty subjects with nonspecific shoulder pain were randomly divided into an experimental group and control group, each with 15 patients. The experimental group used an GSE, whereas the control group did SSE. All subjects were measured in shoulder stability, scapular symmetric alignment, pain, muscle power, and range of motion before and after the intervention. Results: GSE resulted in significantly better shoulder stability (p=.046, from $8.67{\pm}7.54$ score to $13.93{\pm}9.40$) in the experimental group compared with SSE in the control group. However, no significant effects were observed for scapular symmetric alignment including the angles of inferior scapular distance (p=.829) and inferior scapular height difference (p=.735), pain (p=.113), muscle power including shoulder flexion (p=.723) and abduction (p=.897) and range of motion including shoulder flexion (p=.853) and abduction (p=.472). Conclusion: These findings suggest that GSE may be more effective in increasing the shoulder stability than the SSE in patients with nonspecific shoulder pain, probably through a centralization effect on the shoulder mechanism.