• Title/Summary/Keyword: Alginate model

Search Result 92, Processing Time 0.026 seconds

Preparation and Release Characteristics of Polymer-Reinforced and Coated Alginate Beads

  • Lee, Beom-Jin;Min, Geun-Hong
    • Archives of Pharmacal Research
    • /
    • v.18 no.3
    • /
    • pp.183-188
    • /
    • 1995
  • Polymeric reinforcement and coatings of alginate beads were carried out to control the release rate of drug from alginate beads. A poorly water-soluble ibuprofen (IPF) was selected as a model drug. A commercially available $Eudragit^{\circledR}$ RS100 was also used as a polymer. Effects of polymeric contents, the presence of plasticizers and amount of drug loading on the release rate of drug were investigated. The release rate of drug from alginate beads in the simulated gastric fluid did not occur within 2 h but released immediately when dissolution media were switched to the simulated intestinal fluid. No significant difference of release rate from polymer-reinforced alginate bead without plasticizers was observed when compared to plain (simple) beads. However, the release rate of drug from polymer-reinforced alginate beads was further sustained and retarded when aluminium tristearate (AT) as a plasticizer was added to polymer. However, polyethylene glycol 400 (PEG400) did not change the release rate of drug from alginate beads although PEG400 was used to improve dispersion of polymer and sodium alginate, and plasticize $Eudragit^{\circledR}$ RS100 polymer. The presence of plasticizer was crucial to reinforce alginate gel matrices using a polymer. As the amount of drug loading increased, the release rate of drug increased as a result of decreasing effects of polymer contents in matrices. The significantly sustained release of drug from polymer-coated alginate beads occurred as the amount of polymer increased because the thickness of coated membrane increased so that cracks and pores of the outer surface of alginate beads could be reduced. The sustained and retarded action of polymer-reinforced and coated beads may result from the disturbance of swelling and erosion (disintegration) of alginate beads. From these findings, polymeric-reinforcement and coatings of alginate gel beads can provide an advanced delivery system by retarding the release rate of various drugs.

  • PDF

A Study on Glycoside Synthesis Using Alginate-enclosed Microspheres (Alginate-enclosed Microspheres를 이용한 배당체 합성에 관한 연구)

  • 김해성;김우식
    • KSBB Journal
    • /
    • v.8 no.4
    • /
    • pp.320-327
    • /
    • 1993
  • Latex microspheres of styrene/acryl copolymer with acrylamide functional group were used for the stable covalent immobilization of an enzyme applicable for enzymatic synthesis of glycoside. The latex microspheres were coated with polyethyleneimine to establish structural and functional properties relevant to the covalent Immobilization with a high retention of activity. Polythyleneimine-coated microspheres satisfactorily immobilized the invertase for methyl fructoside synthesis, and model reaction were formed into alginate-enclosed microspheres biocatalyst. Using the alginate-enclosed microspheres biocatalyst, the yield of model glycoside was obtained as high as 52.2% at concentration of aqueous 30%(v/v) methanol and 0.291mo1/1 sucrose solution with 2U/ml of activity. The present study showed that the latex microspheres were successfully applied to enzymatic synthesis of glycoside.

  • PDF

Effect of mixing method and storage time on dimensional stability of alginate impressions materials (혼합 방법과 보관 시간이 알지네이트 인상재의 체적 안정성에 미치는 효과)

  • Bang, Hyun-Ji;Shim, Hyun-Ah;Cho, Young-Eun;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.86-94
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the volume stability depending on the mixing methods and storage time for the conventional alginate and extended-pour alginate. Materials and methods: An arch-shaped metal model was fabricated, and one conventional alginate and two extended-pour alginates were used to take impressions using different mixing methods (hand and automatic). 120 impressions were taken (40 per each alginate) and stone models were made in accordance with the different storage times (immediate, 2 days, 5 days, and 6 days). The models were scanned with a 3D table scanner and dimensional change was measured by superimposing the scan data. Using SAS 9.4 (SAS Institute Inc., Cary, NC, USA), the general linear model and Tukey's post hoc test was conducted for statistical analysis (P<.001). Results: There was no statistically significant difference in the dimensional accuracy between two mixing methods, and the volume change was minimum when the stone was poured immediately in all groups. Dimensional accuracy showed a statistically significant difference between groups after 2 days of storage, and extended-pour alginate showed higher accuracy after 5 days of storage comparing to conventional one. Large amounts of volume change were showed at 2 - 5 days for conventional alginate and at 5 - 6 days for extended pour alginate. Conclusion: The mixing method of alginate does not affect volume stability. Although extended-pour alginate has better volume stability than conventional alginate for a long time, it is recommended to pour stone as soon as possible.

The effect of disinfectants for Alginate impression (알지네이트 인상체에 대한 상업성 소독제의 효과)

  • Kim, Seon-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.243-250
    • /
    • 2001
  • To evaluate the effect of disinfectants for Alginate impression, several commercially available disinfectants were tested to Alginate model contaminated by Methicillin resistant Staphylococcus aureus. Alginate specimens were artificially contaminated by Staphylococcus aureus and soaking in four commercially available disinfectants for 1, 5, 10 minutes and colonies were counted for each case. Significant reduction of bacterial colony counts was noted after soaking in 0.5% and 0.05% sodium hypochlorite and after soaking in 2% glutaraldehyde, but not after soaking in Hypochlorus add. Commercially available sodium hypochlorite and glutaraldehyde were found to be effective disinfectants for Alginate impression. But hypochlorus add was not adequate disinfectant.

  • PDF

Preparation and pH-Sensitive Release Behavior of Alginate/Activated Carbon Composite Magnetic Hydrogels

  • Han, Min-Hee;Yun, Ju-Mi;Lee, Young-Seak;Kim, Hyung-Il
    • Carbon letters
    • /
    • v.11 no.2
    • /
    • pp.122-126
    • /
    • 2010
  • The alginate-based hydrogel was prepared as a pH-sensitive drug delivery system. To enhance the drug loading capacity, activated carbon was introduced as a drug absorbent. The iron oxide was incorporated into the alginate matrix for the magnetic transferring to the target organ. The activated carbon and iron-oxide were dispersed uniformly in the alginate hydrogel. The drug release from the alginate/activated carbon composite hydrogel was carried out in various pH conditions with vitamin B12 and Lactobacillus lamnosers as model drugs. The fast and sustainable release of drug was observed in the basic condition due to the pH-sensitive solubility of alginate. The novel drug delivery system having pH-sensitive release property and magnetic movement to target place was developed by using the alginate/activated carbon composite magnetic hydrogels.

Effects of $\gamma$-Irradiation on the Antiallergic Activity of Alginate

  • Song, Eu-Jin;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Park, Jin-Gyu;Kim, Jae-Hun;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Food Science and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.1003-1009
    • /
    • 2008
  • This study was performed to determine the effects of $\gamma$-irradiation on the antiallergic activity of alginate. An alginate aqueous solution was $\gamma$-irradiated at 3, 5, 7, 10, 20, and 100 kGy. First, the molecular weight (Mw) of alginate rapidly decreased as the $\gamma$-irradiation dose increased up to 20 kGy. Then, the antiallergic activity of the $\gamma$-irradiated alginate was measured. Interlukin (IL)-4 cytokine and IgE level were significantly decreased in the $\gamma$-irradiated alginate groups as compared to the control group in vitro. The mice intraperitoneally administered with the $\gamma$-irradiated alginate exhibited lower ovalbumin-specific IgE and IgG1 level in serum than the control mice. Furthermore, the $\gamma$-irradiated alginate suppressed total and ovalbumin-specific IgE secretions in the splenocytes. Increased IL-2 level was observed in the culture supernatants of the splenocytes that were obtained from the mice administerd with the $\gamma$-irradiated alginate, while IL-4 level decreased. The present study indicates that $\gamma$-irradiated alginate can suppress allergy in a mouse allergy model.

Kinetics of Water Vapor Absorption by Sodium Alginate-based Films

  • Seog, Eun-Ju;Zuo, Li;Lee, Jun-Ho;Rhim, Jong-Whan
    • Preventive Nutrition and Food Science
    • /
    • v.13 no.1
    • /
    • pp.28-32
    • /
    • 2008
  • Water vapor sorption by sodium alginate-based films may result in swelling and conformational changes in the molecular structure and affecting the water vapor barrier properties. Sodium alginate film specimens were dried in a vacuum freeze dryer and their moisture content was determined by an air-oven method. The water vapor absorption was determined at two different levels of water activities (0.727 and 0.995) and at three temperatures (10, 20, and $30^{\circ}C$), and kinetics were analyzed using a simple empirical model. Reasonably good straight lines were obtained with plotting of 1/($m-m_0$) vs 1/t. It was found that water vapor absorption kinetics of sodium alginate films were accurately described by a simple empirical model. The rate of water vapor sorption increased with increase in temperature and it showed temperature dependency following the Arrhenius equation. The activation energies varied from 49.18$\sim$149.55 kJ/mol depending on the relative humidity.

Detection and Kinetics of Mucosal Pathogenic Bacteria Binding with Polysaccharides

  • Chung, Kyong-Hwan;Park, Jung-Soon;Hwang, Hyun-Soo;Kim, Jin-Chul;Lee, Ki-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.7
    • /
    • pp.1191-1197
    • /
    • 2007
  • The detection and kinetics of mucosal pathogenic bacteria binding on polysaccharide ligands were studied using a surface plasmon resonance biosensor. The kinetic model applied curve-fitting to the experimental surface plasmon resonance sensorgrams to evaluate the binding interactions. The kinetic parameters for the mucosal pathogenic bacteria (Pseudomonas aeruginosa, Pseudomonas fluorescens, Serratia marcescens) with the alginate ligand were determined from a kinetic model. In addition, the binding interactions of the mucosal pathogenic bacteria with polysaccharide binding pairs (Pseudomonas aeruginosa/alginate, Streptococcus pneumoniae/pneumococcal polysaccharide, Staphylococcus aureus/pectin) were also compared with their kinetic parameters. The rate constants of association for Pseudomonas aeruginosa with the alginate ligand were higher than those for Pseudomonas fluorescens. Serratia marcescens had no detectable interaction with the alginate ligand. The adhesion affinity of Pseudomonas aeruginosa with alginate was higher than that for the other binding pairs. The binding affinities of the pathogenic bacteria with their own polysaccharide were higher than that of Staphylococcus aureus with pectin. Measuring the contact angle was found to be a feasible method for detecting binding interactions between analytes and ligands.

Preparation and evaluation of GFP-containing microspheres for oral vaccine delivery system (경구용 백신수송체용 GFP 함유 마이크로스피어의 제조 및 평가)

  • Jiang, Ge;Park, Jong-Pil;Kwak, Son-Hyok;Hwang, Sung-Joo;Maeng, Pil-Jae
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.253-258
    • /
    • 2000
  • In order to design the oral vaccine delivery system, we prepared the alginate micro spheres containing GFP (green fluorescent protein) as a model drug by spray method. To optimize the preparation conditions of microspheres, we investigated the effects of various parameters including nozzle pressure, nozzle opening angle, and concentrations of sodium alginate and calcium chloride. The prepared microspheres were evaluated by measuring their sizes, loading efficiency, and morphology. The particle size of microspheres was affected by the concentration of sodium alginate and calcium chloride, nozzle pressure, and nozzle opening angle. As the concentration of sodium alginate increased, GFP loading efficiency and particles size of microsphere also increased. However, it was observed to be difficult to spray the sodium alginate solution with concentration greater than 1.5% (w/v), due to high viscosity. The pressure over $3\;kgf/cm^2$ didn't affect the size of particles. As a result, the spraying method enabled us to prepare microspheres for oral vaccine delivery system. In this study, microspheres prepared with 1% (w/v) sodium alginate had greater loading efficiency and better spherical shape.

  • PDF

Selective adsorption of Ba2+ using chemically modified alginate beads with enhanced Ba2+ affinity and its application to 131Cs production

  • Kim, Jin-Hee;Lee, Seung-Kon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3017-3026
    • /
    • 2022
  • The 131Cs radioisotope with a short half-life time and high average radiation energy can treat the cancer effectively in prostate brachytherapy. The typical 131Cs production processes have a separation step of the cesium from 131Ba to obtain a high specific radioactivity. Herein, we suggested a novel 131Cs separation method based on the Ba2+ adsorption of alginate beads. It is necessary to reduce the affinity of alginate beads to cesium ions for a high production yield. The carboxyl group of the alginate beads was replaced by a sulfonate group to reduce the cesium affinity while reinforcing their affinity to barium ions. The modified beads exhibited superior Ba2+ adsorption performances to native beads. In the fixed-bed column tests, the saturation time and adsorption capacity could be estimated with the Yoon-Nelson model in various injection flow rates and initial concentrations. In terms of the Cs elution, the modified alginate showed better performance (i.e., an elution over 88%) than the native alginate (i.e., an elution below 10%), indicating that the functional group modification was effective in reducing the affinity to cesium ions. Therefore, the separation of cesium from the barium using the modified alginate is expected to be an additional option to produce 131Cs.