• 제목/요약/키워드: Alginate impression

검색결과 33건 처리시간 0.025초

탄성고무인상재에 따른 초경석고 모형의 정밀도에 관한 연구 (ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS)

  • 김기홍;장익태;임순호
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.301-312
    • /
    • 1999
  • The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone mod els were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were made with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to poly-sulfide, exress, and alginate in reproducing full arch mode (p<0.05) 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate(p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05) 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).

  • PDF

치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향 (Effect of interproximal undercut on the dimensional accuracy of impression)

  • 이주리;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.330-336
    • /
    • 2015
  • 목적: 본 연구의 목적은 치간 유두의 소실로 인해 치아 사이에 언더컷이 존재하는 경우 이것이 인상체의 정확도에 영향을 미치는지 알아보고자 하는 것이다. 재료 및 방법: 2종류의 부가중합형 실리콘 인상재($Extrude^{(R)}$ Wash, $Imprint^{TM}$ II Quick Step Light Body)와 한 종류의 알지네이트 인상재(Cavex Impressional)로 상악 주모형의 인상을 채득하여 얻은 실험모형상의 두 점 사이의 거리를 측정하여 주모형과 비교하여 모형의 변형 정도를 측정하였다. 세 종류의 인상재에서 얻은 실험 모형들을 치간 유두가 존재하는 군과 존재하지 않는 군으로 나눠 총 6개의 군을 평가하였으며, 각 군당 6개의 모형을 측정하였다. 삼차원 광학 스캐너로 실험모형을 스캔한 후, 하나의 모형당 6개의 두 점 사이의 거리를 삼차원 디지털 계측 소프트웨어 상에서 측정하였다. 측정 거리의 변화 정도를 백분율로 계산하여 모형의 변형률을 구하였으며, 이것을 이원분산분석을 이용하여 유의수준 .05에서 분석하였다. 결과: 측정거리 6개 중 3개에서 인상재에 따라 통계적으로 유의한 차이를 보였다. 반면, 치간 유두의 존재 여부에 따른 차이는 알지네이트 인상재에서 하나의 측정 거리에서만 유의한 차이를 보였을 뿐(P=.047), 다른 측정거리들과 인상재에서는 통계적으로 유의성 있는 차이를 나타내지 않았다. 결론: 치간 유두의 소실로 인한 언더컷의 존재가 부가중합형 실리콘 인상재와 알지네이트 인상재의 체적 정확도에 미치는 영향은 크지 않았다.

AN STUDY ON THE DIMENSIONAL CHANGE OF PLASTER TO TIME WITH IMPRESSION MATERIALS

  • 최석순
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.43-46
    • /
    • 1988
  • The purpose of this investigation was to determined the dimensional change of plaster to time with impression materials. This study was carried out through the literature & experiment, using 4sorts of the Impression Materials(Alginate, Impression Agar, Silicone Rubber, Polysulfide Rybber)and 5 treatments(1hr, 11/2 hrs, 2hur, 3hur, 6hur). The results of this experiment were as follows : 1. Main effect of Impression Meterials & tretments was statistically significant.(P<0.01). 2. The effect of 2-way interaction of Impression materials & Treatments was also statistically significant.(P<0.01) 3. Though this study was the difference of degree according to the materials. All Impression Materials were tended to be constained according to over the time.

  • PDF

폐렴을 동반한 턱관절 탈구환자에서 인상채득 중 유발된 급성 호흡장애 (Acute Respiratory Distress during Impression Taking in a TMJ Dislocation Patient with Pneumonia)

  • 손정석;오지현;유재하;김종배
    • 대한치과마취과학회지
    • /
    • 제14권2호
    • /
    • pp.119-126
    • /
    • 2014
  • Difficulty in breathing can be very disconcerting to a patient who is conscious yet unable to breath normally. The common causes of acute respiratory distress include hyperventilation, vasodepressor syncope, asthma, heart failure, and hypoglycemia. In most of these situations, the patient does not exhibit respiratory distress unless an underlying medical disorder becomes acutely exacerbated. Examples of this include acute myocardial infarction, anaphylaxis, cerebrovascular accident, hyperglycemia, and hypoglycemia. A major factor that leads to the exacerbation of respiratory disorders is undue stress, either physiologic or psychologic. Psychologic stress in dentistry is the primary factor in the exacerbation of preexisting medical problems. Therefore, the most dental patient should be cared gently as the stress reduction protocol. This is a case report of acute respiratory distress with vasodepressor syncope during alginate impression taking of mandibular teeth in a long-standing temporomandibular joint dislocated 93-years-old pneumonic patient.

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제46권3호
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

알지네이트 인상재의 정확한 사용법 (Correct methods for using alginate Impression materials)

  • 김우현;김경남
    • 대한치과의사협회지
    • /
    • 제43권9호통권436호
    • /
    • pp.576-581
    • /
    • 2005
  • 오늘날 알지네이트 인상재는 다른 어떠한 인상재보다 널리 사용되고 있다. 이는 알지네이트 인상재가 ①사용하기 쉽고, ②환자에게 거부감이 적고, ③특수한 장비의 사용이 필요하지 않으며, ④정확히 사용하면 상당히 정밀한 인상이 가능하기 때문이다. 알지네이트 인상재의 정확한 사용법을 정리한다.

  • PDF

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석 (Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions)

  • 주용훈;이진한
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.316-328
    • /
    • 2015
  • 목적: 보관 조건과 석고 주입 시간에 따라 알지네이트 인상체로부터 제작된 모형의 정확성을 알아보고자 하였다. 연구 재료 및 방법: 채득된 알지네이트 인상체는 습도가 유지되는 항습조에 보관하는 것과 진료실 내의 공기 중에 노출되는 상태로 보관 조건을 달리하였다. 보관 조건에 따라 각각 즉시, 채득된 후 10분, 30분, 180분, 360분으로 나누어 보관한 후에 석고 모형을 제작하였다. 제작된 석고 모형을 3D 레이저 스캐너로 삼차원 디지털 모형을 구성하였고 구성된 디지털 모형의 참고점에서 거리를 측정하여 변형률을 비교하였다. 또한 각 실험군의 삼차원 디지털 평균 모형을 제작한 후 중첩을 시행함으로써 표면 변위가 발생한 부위와 크기를 확인하였다. 결과: 인상 채득 즉시 제작한 모형의 변형률이 가장 작게 나타났고, 공기 중에 보관한 인상체보다 항습조에 보관한 인상체의 변형률이 작게 나타났다. 석고 주입 시간이 증가함에 따라서 변형률도 증가하였으며, 석고 주입 시간이 180분을 지나면 보관 조건에 관계없이 대구치 부위에서 변형률과 표면 변위가 증가한다. 결론: 알지네이트 인상체로부터 제작된 모형의 정확성을 위해서는 인상 채득 후, 즉시 모형을 제작해야 한다. 보관이 필요한 경우에는 100% 상대습도가 유지되는 항습조를 이용하고, 보관 시간은 180분을 넘지 않도록 해야 정확한 모형을 얻을 수 있다.

합성수지 재료에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구 (Retentive Force of Adjustable Dental Impression Trays with Different Synthetic Resin Materials)

  • 이인섭;이진한;김유리;동진근
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.11-21
    • /
    • 2006
  • The adjustable dental impression trays were made for being adjusted their width automatically along the width of patient's dental arch. The purpose of this study was to investigate the retentive force of adjustable dental impression trays made of different synthetic resin materials. Three pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) synthetic resin, polyurethane synthetic resin and polycarbonate synthetic resin with a hole and without a rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray jig which was made for holding the tray on the lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the alginate impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum force by use of UTM at a constant strain rate 100mm per minute. The results obtained in this study were as follows : 1. The upper trays were showed higher retentive force than lower trays in three tray materials. 2. There was no significant difference in the retentive force of the tray materials(p>0.05).

Acidic hydrogen peroxide를 이용한 어둡거나 다양한 색상의 표면에 부착된 혈흔의 증강 (Enhancement of bloodstain on the dark or multi-colored surfaces by using the acidic hydrogen peroxide)

  • 홍성욱;이원영;변재영;신현주;하재욱
    • 분석과학
    • /
    • 제36권3호
    • /
    • pp.121-127
    • /
    • 2023
  • 범죄 현장에서 혈액을 찾아 식별하는 것은 신원 확인 및 사건 재구성을 하기 위해 중요한 과정이다. 하지만, 혈액은 어둡거나 다양한 색상의 표면에서 육안으로 관찰하기 어려울 수 있다. Acidic hydrogen peroxide (AHP)는 최근에 발표된 혈액 증강 시약으로, 카메라의 장노출 기능을 사용하면 혈액을 높은 감도로 관찰할 수 있다. 그러나 어둡거나 다양한 색상의 표면에서 기존에 알려진 기법과 비교된 바는 없다. 이를 위해, 어둡거나 다양한 색상의 표면 8 종류에 혈흔족적을 남기고 UV나 IR을 비추면서 관찰/촬영하는 방법, alginate 전사법, leuco rhodamine 6G (LR6G), AHP를 적용하여 비교하였다. 그 결과, AHP는 UV 및 IR 촬영법보다 증강한 혈액과 표면의 contrast가 높았고, alginate 전사법과 달리 모든 표면에서 적용이 가능했다. 또한 LR6G와 마찬가지로 AHP 역시 어둡거나 다양한 색상의 표면에 부착된 혈액을 성공적으로 증강하였다.