• Title/Summary/Keyword: Air spring

Search Result 838, Processing Time 0.024 seconds

A Study of Pneumatic Reaction Force of Air Chamber for an OWC type Wave Energy Device by Forced Heave Experiments (강제동용시 OWC형 파력발전 공기챔버의 공기반력 실험연구)

  • CHOI Hark-Sun;LEW Jae-Moon;HONG Seok-Won;KIM Jin-Ha
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.212-219
    • /
    • 2004
  • The effect of frequency and amplitude of the OWC (Oscillating Water Column) motion on the nonlinear reaction forces in an air duct arc studied experimentally. Experimental OWC model is idealized as a simple circular cylinder with an orifice type air duct located at the middle of the top rid. Reaction forces due to forced heave oscillation are measured and analyzed. By subtracting the effect of inertia forces and restoring forces, pneumatic damping force and added spring force are deduced. The effects of the frequency and amplitude of the heave motion are discussed. Also, the effects of solidity of the duct on the reaction forces are discussed.

  • PDF

A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House (공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구)

  • 함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF

A Study on the Measurement and Evaluation of lndoor Air Quality in School (학교 건축물의 실내공기질 측정 및 평가에 관한 연구)

  • Kim, Tae-Woo;Kim, Hyun-Tae;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.307-310
    • /
    • 2005
  • In recent years, our society is confronted with many environmental problems. Among them, Especially, Sick House Syndrome is brought into relief as a society's issue and the people's concern of Indoor Air Quality is also increased. Nowadays, about 20percent of korean children is suffered from allergic respiratory diseases such as asthma or rhinitis. From student's physical and mental point of view, indoor environmental condition of school is very important and must be kept by strict regulation Therefore, the aim of this thesis is focused on the measurement and analysis of indoor air quality of classroom.

  • PDF

Variations in Air Temperature and Water Temperature with Tide at the Intertidal Zone : Odo Island, Yeosu (조간대에서 조위에 따른 기온과 수온 변화 : 여수 오도섬)

  • Won Gi Jo;Dong-hwan Kang;Byung-Woo Kim
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1027-1038
    • /
    • 2022
  • The intertidal zone has both land and marine characteristics and shows complex weather environments. These characteristics are suited for studying climate change, energy balance and ecosystems, and may play an important role in coastal and marine weather prediction and analysis. This study was conducted at Odo Island, approximately 300m from the mainland in Yeosu. We built a weather observation system capable of real-time monitoring on the mud flat in the intertidal zone and measured actual weather and marine data. Weather observation was conducted from April to June 2022. The results showed changes in air temperature and water temperature with changes in the tide level during spring. Correlation analysis revealed characteristic changes in air temperature and water temperature during the day and night, and with inundation and exposure.

A Geothermal Model of Pit Area Using Computational Fluid Dynamics (CFD를 이용한 피트의 지중열 모델 구축에 관한 연구)

  • Min, Joon Ki;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.11-16
    • /
    • 2008
  • This research has established CFD model on pit's cool-tube system through heat and air movement simulations, of which data was based on experimental and verification. This research work verified the effectiveness of the cool-tube system by analysing temperature, humidity and air current of the actually installed case. Also, we analysed heat transfer through air current simulation and the results are as followings. Firstly, we experiment on temperature, humidity and speed of air currents of the cool tube system with pit space during the month of May (spring). The average exterior temperature was $16.1^{\circ}C$, and $18.2^{\circ}C$ for the pit, $24.7^{\circ}C$ for the compressor room. Secondly, based on measured data of real case, we have analysed heat transfer through air current simulation and verified our proposed model. The actual measurement of average temperature of exhaust air of the pit's area is $19.7^{\circ}C$ with tolerance of $-0.33^{\circ}C{\sim}-0.6^{\circ}C$ compared to above simulations. Thirdly, having verified air current simulation model with formation of 260,000 and 1,000,000 cells, we could get reasonable near values with 260,000 cells. Lastly, the next step of research would be focused on proposing the best possible pit's cool-tube system after analysis of heat transfer of the air current simulation based on verified CFD model.

Effects of Elevated Spring Temperatures on the Growth and Fruit Quality of the Mandarin Hybrid 'Shiranuhi' (봄철 가온처리가 부지화의 생장과 과실품질에 미치는 영향)

  • Moon, Young-Eel;Kang, Seok-Beom;Han, Seung-Gab;Kim, Yong-Ho;Choi, Young-Hun;Koh, Seok Chan;Oh, Soonja
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.459-469
    • /
    • 2015
  • The effects of elevated spring temperatures on the growth and fruit quality of the mandarin hybrid 'Shiranuhi' [(Citrus unshiu ${\times}$ C. sinensis) ${\times}$ C. reticulata] were investigated in plastic greenhouses, to develop a cropping system to improve the quality of the fruit and increase the income of growers on Jeju Island, South Korea. Under conditions of elevated temperature I ($25/15^{\circ}C$, day/night) and elevated temperature II ($28/18^{\circ}C$, day/night) during early spring, budburst was advanced by 11 and 15 d, and full bloom by 22 and 45 d, respectively, compared to those of the plants grown at ambient air temperature in a plastic greenhouse. Elevated temperatures decreased the number of spring shoots but increased mean spring shoot length and leaf area. Growing 'Shiranuhi' trees at elevated temperatures resulted in increases in mean fruit weight and fruit L/D ratio (> 1.0). In addition, fruit color development was significantly advanced in trees grown under elevated temperatures during early spring, which allowed the fruit to be harvested 1-2 months earlier than trees grown under ambient air temperature. Fruit soluble solids content (SSC) and titratable acidity (TA) at harvest were similar between elevated temperature I and ambient air temperature, but were significantly higher than at elevated temperature II. Considering fruit quality, harvest time, and yield, the elevated temperature treatment regime of $25/15^{\circ}C$ (day/night) during early spring could be useful for cultivation of the mandarin hybrid 'Shiranuhi' to increase the income of growers.

A Measurement and Evaluation of Indoor Thermal Conditions in Spring of a Coastal Passenger Ship - 590-Passenger Ro-Pax Type (590인승 Ro-Pax형(型) 연안여객선의 선실 내 봄철 온열환경 측정평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Eun-Su;Do, Yo-Han;Choi, Yun-Seok;Cho, Jung-Yul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1170-1177
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions in the spring of a korean coastal passenger ship which is 590-passenger Ro-Pax type built at 1997. Especially this study has focussed on the relations between the diffuser open ratio, which can be controlled by 12 steps, and the comfort. Followings are the results of this study. (1) The supply air volume to cabins are maximum 4.3 and 2 times more than design quantity when the diffusers in cabins are open 100% and 50%, respectively. (2) Regardless of diffuser open ratio, the supply air maintains constantly high temperature and below 10% of relative humidity through the experimental days. (3) All the cabins are not satisfied with the ASHRAE comfort criterion at the condition of 100% and 50% of diffuser open ratio, because of high temperature and low relative humidity. (4) At a low diffuser open ratio, number of cabins which satisfy the ASHRAE comfort criterion are increased. (5) Humidifying and dehumidifying, and hvac control system of each cabin must be reviewed and studied at the view of passengers to service more comfort environments.

Influence of Stratospheric Intrusion on Upper Tropospheric Ozone over the Tropical North Atlantic

  • Kim, So-Myoung;Na, Sun-Mi;Kim, Jae-Hwan
    • Journal of the Korean earth science society
    • /
    • v.29 no.5
    • /
    • pp.428-436
    • /
    • 2008
  • This study observed the upper tropospheric ozone enhancement in the northern Atlantic for the Aerosols99 campaign in January-February 1999. To find the origin of this air, we have analyzed the horizontal and vertical fields of Isentropic Potential Vorticity (IPV) and Relative Humidity (RH). The arch-shaped IPV is greater than 1.5 pvus indicating stratospheric air stretches equatorward. These arch-shaped regions are connected with regions of RH less than 20%. The vertical fields of IPV and RH show the folding layer penetrating into the upper troposphere. These features support the idea that the upper tropospheric ozone enhancement originated from the stratosphere. Additionally, we have investigated the climatological frequency of stratospheric intrusion over the tropical north Atlantic using IPV and RH. The total frequency between the equator and $30^{\circ}N$ over the tropical north Atlantic exhibits a maximum in northern winter. It suggests that the stratospheric intrusion plays an important role in enhancing ozone in the upper troposphere over the tropical north Atlantic in winter and early spring. Although the tropospheric ozone residual method assumed zonally invariant stratospheric ozone, stratospheric zonal ozone variance could be caused by stratospheric intrusions. This implies that stratospheric intrusion influences ozone variance over the Atlantic in boreal winter and spring, and the intrusion is a possible source for the tropical north Atlantic paradox.

On the occurrence of yellow sand and atmospheric loadings (황사의 사례분석과 한반도 유입량)

  • 정용승;윤마병
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.233-244
    • /
    • 1994
  • The phenomenon of yellow sand (dust clouds) occurred in Korea during the spring of 1993 and 1994 is studied in detail. In total 6 cases including 15 days of yellow sand were observed in 1993 and the annual number of these events was found to increased. Examinations in this study include meteorological charts satellite imagery, pilot reports (PIREP) of Korea Air Force, and air concentrations of total suspended particulates(TSP). We present on estimation of total atmospheric loadings based on the observation and theory. According to the PIREP, in general the dust clouds travelled in the lower troposphere up to the level 5km. The visibility within the clouds was in the range of 3-8km The area covered by yellow sand in an event exceeded 0.4 M $\textrm{km}^2$ . According to trajectory analyses, dust clouds invaded Korea in April and May 1993 were landed in the sink area after 2~4 days travelling for 2,000~3,000km from a source region. Estimates of total atmospheric loadings of a dust cloud for April 23~24 in 1993 were 1.5 M ton. In addition, 7 dust storms were also reported in synoptic observations in NW China and Mongolia during the spring in 1994. The yellow sand was not reported with meteorological observations in Korea, however pilots reported significant dust clouds over the Yellow Sea on 8 and 13 April and 20 May 1994.

  • PDF

A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship (신조 운항실습선의 봄철 실내 온열환경 실측평가)

  • Shin, Dong-Keol;Lee, Jin-Uk;Lee, Hyong-Ki;Park, Youn-Cheol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.