Abstract
The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.