• Title/Summary/Keyword: Air gap thickness

Search Result 97, Processing Time 0.024 seconds

The Designing of an Air-gap Type FBAR Filter using Leach Equivalent Model

  • Choi, Hyung-Wook;Jung, Joong-Yeon;Lee, Seung-Kyu;Park, Yong-Seo;Kim, Kyung-Hwan;Shin, Hyun-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.4
    • /
    • pp.196-203
    • /
    • 2006
  • An air-gap type FBAR was designed using Leach equivalent model for analyzing a vertical structure of the FBAR. For the top electrode, Pt, and the bottom electrode, Au, of $1.2{\mu}m$ thickness and the piezoelectric of 0.8,urn thickness, the resonance and anti-resonance occurred at 2.401 GHz and 2.460 GHz, respectively. $S_{11}$ was increased and $S_{21}$ was decreased as the resonance area of FBAR was widened. We observed the characteristics of insertion loss, bandwidth and out-of-band rejection of ladder-type FBAR BPF by changing resonance areas of series and shunt resonators and by adding stages. As the resonance area of series resonator was increased, insertion loss was improved but out-of-band rejection was degraded. And as the resonance area of shunt resonator was increased, insertion loss was degraded a little but out-of-band rejection was improved even without adding stages. We, also, changed the shape of the resonance area from square shape to rectangle shape to examine the effects of the resonator shape on the characteristics of the BPF. The best performances were observed when the sizes of series and shunt resonator are $150{\mu}m{\times}l50{\mu}m\;and\;5{\mu}m{\times}50{\mu}m$, respectively. Out-of-band rejection was improved about 10dB and bandwidth was broadened from 30MHz to 100MHz utilizing inductor tuning on $2{\times}2\;and\; 4{\times}2$ ladder-type BPFs.

Effect of Refining Conditions and Grammage on the Bending Stiffness of Linerboard (고해 조건과 평량이 라이너 판지의 휨강성에 미치는 영향)

  • Won Jong Myoung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.3
    • /
    • pp.44-51
    • /
    • 2004
  • The effect of refining conditions and grammage on the stiffness of linerboard was investigated. The correlations between Taber stiffness and resonance stiffness were very low due to the different measuring principle. The refining conditions did not affect sig nificantly on both Taber and resonance stiffness estimated here. This means that it is strongly recommended to find and apply the refining conditions which can reduce specific energy consumption. Taber stiffness showed very high correlation for the thickness and elastic modulus of linerboard, while the resonance stiffness showed much lower correlation. Effective thicknesses for Taber stiffness were very well fitted with measured thickness, while those for resonance stiffness depended on the grammage of linerboard.

A Stress Analysis Method for the Rotor Design of an IPMSM Considering Radial Force

  • Kim, Won-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.888-892
    • /
    • 2014
  • In the design of the rotor of an interior permanent magnet synchronous motor (IPMSM), the bridge between the permanent magnets helps prevent the scattering of permanent magnets and pole pieces during high-speed operation. In the design of a motor, if the bridge is too thick, its performance will be largely degraded because of flux leakage. Additionally, if the bridge is too thin, its mechanical safety cannot be guaranteed. Thus, an accurate analysis method is required to determine the thickness of the bridge. Conventional stress analysis methods determine the thickness of the bridge by only considering the centrifugal force of the rotors. In this study, however, a method that additionally considers the radial force generated by the air-gap flux density based on the conventional methods is proposed and reflected in the design of a traction motor for electric vehicles. Finally, the validity of this study is verified through a reliability test related to high-speed operation.

Optimal design of High precision Maglev system using Finite Element Method and Design Of Experiments (유한 요소법과 실험계획법을 병행 사용한 고정밀 자기 부상 시스템의 최적 설계)

  • Lee, Sung-Gu;Won, Sung-Hong;Lee, Hyung-Woo;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1267-1269
    • /
    • 2005
  • This paper presents the design for improving performance of the high-precision Magnetic levitation system. Motor performance on various design schemes such as thickness and magnetizing patterns of the permanent magnets, pole pitch, length of air gap, turn number of windings, and thickness of the aluminum-core has been investigated in detail by using FEM(Finite Element Method) Simulation-based DOE(Design of Experiments) method is also applied in order to reduce the large number of analysis according to each design variable and consider the effect among variables. The design in all aspects is proposed by an optimization algorithm using regression equation derived from the simulation-based DOE.

  • PDF

Acoustic Absorption Coefficient and Impedance of Wood Sections (목재단면(木材斷面)의 흡음계수(吸音係數)와 음향(音響)임피이던스)

  • Hong, Byung-Wha
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.26-33
    • /
    • 1989
  • The acoustic absorption coefficient and acoustic impedance of 5 species of softwood(sonamoo, sam namoo, gusang namoo, hwaback, sitka spruce) and 5 species of hardwood (Mulgusul namoo, Italian popular, white meranti, red meranti, kalantas) were measured by the standing wave method. which is simple in the setup and gives more accurate result than does any other measuring method. The dependence of the absorption coefficient and complex acoustic impedance on the wood sections. thickness of the sample itself and the back air gap was investigated experimentally in the frequency range from 200Hz to 1800Hz, and the result are as follows: 1. The acoustic absorption coefficient of wood sections was higher on the cross section than radial and tangential sections. 2) The acoustic absorption coefficient were higher in the frequency range from 400Hz to 600Hz, but decreased in the frequency above 600Hz. 3. The genenal tendency of the variation of the normal acoustic impedance was increased according to the frequency. 4. The acoustic absortion coefficient was increased in the to 7mm-thick sample and decreased in 9mm-thick sample. 5. The higher acoustic absorption coefficient was shown in the case with the backing an gap than in the case without the gap.

  • PDF

An Effect Absorption Property of Compound Absorption Structure on the Membranous and the Back Resonator type (표면재 및 배후 다공질재의 유형에 따른 복합 흡음구조의 흡음특성)

  • 김태훈;주문기;오양기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.65-71
    • /
    • 2001
  • Absorbers such as porous materials and panels have limited absorption characteristics to some frequency bands. There is a need for absorbers with high absorption coefficients in a wide frequency ranges to make good response of room acoustics. This is almost impossible for a single absorption material. Composite absorption structure with cover, porous material. and air gap is known to have those wide frequency characteristics. In this basis. various composite absorption structures are measured and investigated as wide range absorption structures. Measurements are performed according to an international standard, ISO 354. Various surface types such as wooden slits, wood/steel perforated panels are selected as surface covers, and also various porous materials such as polyurethanes, polyesters, and glasswools are used inside the covers. Result shows that the area of void parts of surface materials is critical to high frequency absorptions, and thickness of air gaps are critical factor of the peak absorptions of low frequency bands.

  • PDF

Investigation of Glass Substrate Sealing for ECL Application using Laser Welding Technology (레이저 웰딩 기술을 이용한 ECL용 유리 기판 접합에 대한 고찰)

  • Sung, Youl-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.28-32
    • /
    • 2015
  • In this work, we reported fabrication of sealing the glass substrate using laser treatment at low temperature for electrochemical luminescence (ECL) cell. The laser treatment at temperature is using laser diode. The glass substrate sealing by laser treatment tested at 3-10W, 2-5 mm/s for build and tested. The sealing laser treatment method will allow associate coordination between the two glass substrate was enclosed. The effect of laser treatment to sealing the glass substrate was found to have cracks and air gap at best thickness of about 550-600 im for condition 3 W, 3 mm/s. The surface of sealing was roughness which was not influent to electrodes It can reduce the cracks, crevices and air gaps as well, improves the performance viscosity in butter bus bar electrodes. Therefore, it is more effective viscosity between two FTO glasses substrate.

Effect of Conductor Radius of Polyesterimide- Polyamideimide Enameled Round Wire on Insulation Breakdown Voltage and Insulation Lifetime

  • Park, Jae-Jun;Shin, Seong-Sik;Lee, Jae-Young;Han, Se-Won;Kang, Dong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.3
    • /
    • pp.146-150
    • /
    • 2015
  • Insulation breakdown voltage and insulation lifetime were investigated in straight lines or twisted pairs with polyesterimide-polyamideimide enameled round wires (EI/AIW ). The enamel thickness was 50 μm and the conducting copper radius was 0.50, 0.75, 1.09, and 1.50 mm, respectively. There were many air gaps in a twisted pair therefore, when voltage was applied to the twisted pair, enamel erosion took place in the air gap area because of partial discharge according to Paschen's law. Insulation breakdown voltage and insulation lifetime were highest in the sample of 0.75 mm conductor radius, which was higher than those values for 0.50 mm or 1.09 and 1.55 mm.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.