DOI QR코드

DOI QR Code

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Kim, Chang-Whe (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Lim, Young-Jun (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Kwon, Ho-Beom (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Kim, Myung-Joo (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University)
  • Received : 2013.09.06
  • Accepted : 2014.01.21
  • Published : 2014.02.28

Abstract

PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.

Keywords

References

  1. Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4: 241-7.
  2. Rangert B. Mechanical and biomechanical guidelines for the use of Brånemark System-general principles. Aust Prosthodont J 1993;7:39-44.
  3. Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-4.
  4. Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-60.
  5. Zarb GA, Symington JM. Osseointegrated dental implants: preliminary report on a replication study. J Prosthet Dent 1983;50:271-6. https://doi.org/10.1016/0022-3913(83)90029-X
  6. Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-5. https://doi.org/10.1016/0022-3913(89)90084-X
  7. Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9: 169-78.
  8. Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-60.
  9. Pietrabissa R, Gionso L, Quaglini V, Di Martino E, Simion M. An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses. Clin Oral Implants Res 2000;11:448-57. https://doi.org/10.1034/j.1600-0501.2000.011005448.x
  10. Jemt T, Linden B. Fixed implant-supported prostheses with welded titanium frameworks. Int J Periodontics Restorative Dent 1992;12:177-84.
  11. Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-5.
  12. Jemt T, Lekholm U. Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits. Clin Oral Implants Res 1998;9:272-80. https://doi.org/10.1034/j.1600-0501.1998.090408.x
  13. Carr AB, Gerard DA, Larsen PE. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996;76: 500-9. https://doi.org/10.1016/S0022-3913(96)90008-6
  14. Rubenstein JE, Ma T. Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks. Int J Oral Maxillofac Implants 1999;14:491-5.
  15. Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996;11:216-22.
  16. Wee AG, Schneider RL, Aquilino SA, Huff TL, Lindquist TJ, Williamson DL. Evaluation of the accuracy of solid implant casts. J Prosthodont 1998;7:161-9. https://doi.org/10.1111/j.1532-849X.1998.tb00199.x
  17. Chang TL, Maruyama C, White SN, Son S, Caputo AA. Dimensional accuracy analysis of implant framework castings from 2 casting systems. Int J Oral Maxillofac Implants 2005; 20:720-5.
  18. Bidez MW, McLoughlin SW, Chen Y, English CE. Finite element analysis of two-abutment Hader bar designs. Implant Dent 1993;2:107-14. https://doi.org/10.1097/00008505-199305000-00008
  19. Romero GG, Engelmeier R, Powers JM, Canterbury AA. Accuracy of three corrective techniques for implant bar fabrication. J Prosthet Dent 2000;84:602-7. https://doi.org/10.1067/mpr.2000.111494
  20. Carr AB, Stewart RB. Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing. J Prosthodont 1993;2:2-8. https://doi.org/10.1111/j.1532-849X.1993.tb00373.x
  21. Linke BA, Nicholls JI, Faucher RR. Distortion analysis of stone casts made from impression materials. J Prosthet Dent 1985;54:794-802. https://doi.org/10.1016/0022-3913(85)90473-1
  22. Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5:331-6.
  23. Gettleman L, Ryge G. Accuracy of stone, metal and plastic die materials. Calif Dent Assoc 1970;46:28-31.
  24. Sutherland JK, Hallam RF. Soldering technique for osseointegrated implant prostheses. J Prosthet Dent 1990;63:242-4. https://doi.org/10.1016/0022-3913(90)90112-P
  25. Hobo S, Ichida E, Garcia LT. Osseointergration and Occlusal Rehabilitation. Chicago, IL: Quintessence Publishing Co. 1989, p. 176.
  26. Sellers GC. Direct assembly framework for osseointegrated implant prosthesis. J Prosthet Dent 1989;62:662-8. https://doi.org/10.1016/0022-3913(89)90587-8
  27. Voitik AJ. The Kulzer abutment luting; Kal technique. A direct assembly framework method for osseointegrated implant prostheses. Implant Soc 1991;2:11-4.
  28. Parel SM. Modified casting technique for osseointegrated fixed prosthesis fabrication: a preliminary report. Int J Oral Maxillofac Implants 1989;4:33-40.
  29. Eisenmann E, Mokabberi A, Walter MH, Freesmeyer WB. Improving the fit of implant-supported superstructures using the spark erosion technique. Int J Oral Maxillofac Implants 2004;19:810-8.
  30. Berger JC, Driscoll CF. Rehabilitation of a spark erosion prosthesis: a clinical report. J Prosthodont 2006;15:113-6. https://doi.org/10.1111/j.1532-849X.2006.00085.x
  31. Preston JD, Reisbick MH. Laser fusion of selected dental casting alloys. J Dent Res 1975;54:232-8.
  32. Weiss PA, Munyon RE. Repairs, corrections and additions to non-precious ceramo-metal frameworks (II). Quintessence Dent Technol 1980;4:45-58.
  33. Kwon JY, Kim CH, Lim YJ, Kim MJ. The dimensional change of cast implant bars after laboratory procedure. J Korean Acad Prosthodont 2007;45:354-61.
  34. Zoidis PC, Winkler S, Karellos ND. The effect of soldering, electrowelding, and cast-to procedures on the accuracy of fit of cast implant bars. Implant Dent 1996;5:163-8. https://doi.org/10.1097/00008505-199600530-00002
  35. Linehan AD, Windeler AS. Passive fit of implant-retained prosthetic superstructures improved by electric discharge machining. J Prosthodont 1994;3:88-95. https://doi.org/10.1111/j.1532-849X.1994.tb00134.x
  36. Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Threedimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont 1993;6:346-63.
  37. Iwasaki K, Ohkawa S, Rosca ID, Uo M, Akasaka T, Watari F. Distortion of laser welded titanium plates. Dent Mater J 2004;23:593-9. https://doi.org/10.4012/dmj.23.593
  38. Jemt T. Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil 1995;22:557-64. https://doi.org/10.1111/j.1365-2842.1995.tb01049.x
  39. Huling JS, Clark RE. Compratative distortion in three-unit fixed prostheses joined by laser welding, conventioanl soldering, or casting in one piece. J Dent Res 1977;56:128-34. https://doi.org/10.1177/00220345770560020501

Cited by

  1. Teriparatide Therapy for Bisphosphonate-Related Osteonecrosis of the Jaw Associated With Dental Implants pp.1056-6163, 2015, https://doi.org/10.1097/ID.0000000000000232