• Title/Summary/Keyword: Air environment

Search Result 10,248, Processing Time 0.034 seconds

Temporal Changes of Hyalessa fuscata Songs by Climate Change (기후변화에 의한 참매미 번식울음 시기 변화 연구)

  • Kim, Yoon-Jae;Ki, Kyong-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.2
    • /
    • pp.244-251
    • /
    • 2018
  • The present study aimed to identify the influence of climate change on mating songs of Cicadidae in a phenological perspective. The research sites were located in the central part of the Korean peninsula in which phenological observations by the Meteorological Office are made. The material provided by the Meteorological Office was used for long term phenological analysis. The findings demonstrated, First, the phenological monitoring of cicada is an effective index to detect ecological changes due to climate change, thus indicating the importance of long term phenological investigations for future studies. Second, the analysis on the phenological changes of H. fuscata presented a trend in which the first songs were made at increasingly earlier and later dates, respectively. The phenological data on H. fuscata and average temperatures exhibited a significant negative correlation between the initial mating song period and the average temperatures of June. Furthermore, there was also a significant negative correlation for precipitation in October with the end time and total duration of H. fuscata song. Third, in the regression analysis of the start of H. fuscata song and meteorological factors in Seoul, increasing average air temperature in spring (March to June), which includes June, was associated with an earlier start time of H. fuscata song, with calling starting approximately 3.0-4.5 days earlier per $1^{\circ}C$ increase. Fourth, in the regression analysis of the end of H. fuscata song and meteorological factors in Seoul, increased mean precipitation in October was associated with an early end time and an overall reduction in the length of the song period. The end time of song decreased by approximately 0.78 days per 1mm increase in precipitation, and the total length of the song period decreased by 0.8 days/1mm. This research is important, as it is the initial research to identify the phenological changes in H. fuscata due to climate change.

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

A Comparative Study of Landscape Characteristics on Bridges in Palaces of Korea and China - Focusing on the Chosun Dynasty and Ming and Qing Dynasties - (한국과 중국의 궁궐 내 교량에 관한 경관특성 비교 연구 - 조선시대와 명·청시대를 중심으로 -)

  • Zhang, Fu-Chen;Lee, Ai-Ran
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.1-12
    • /
    • 2019
  • A bridge is a structure constructed on water or in the air for convenient passage. Compared to other buildings, the building materials and structures of bridge required unique functions to cross the space. It depends on the productivity of the building, the level of science and technology, and the ecological environment of the building site. Also, it has important relationship with functions such as politics, military, economy, and life. Most of the academic research on bridges is focused on research in the field of bridge-building technology, so the study on the landscape aesthetics and history of bridges is lacking. Against this backdrop, the study will be valuable as a accumulation of both countries' understanding of bridge types, history and culture, as well as technical and aesthetic data, by analyzing the bridges located within the palaces of Korea and China. The research method is to analyze the bridge through field survey and literature analysis.. First, the bridges of royal palace of Korea and China are to be classified quantitatively as physical shapes, landscapes, and decorations by comparing the materials, forms, landscapes, and decorative culture of bridges. Second, characteristics, common points, and differences are extracted by classifying bridges of both countries. Also, the results are discussed based on the physical environment or cultural background. This would be worth cross-referencing in the building technology and aesthetics of the two countries. For the first important characteristics of result, main materials of Korean and Chinese palaces are stone. However, the bridge in China's royal palaces is also focused on wood. Second, in terms of form, the bridges in the royal gardens of Korea and China are all based on the beam bridge. However, the specific form, ratio, style of the beam bridge, and airspace of arched bridge are very different. Third, most of the connection methods are focused on the over bridge. It values the convergence with the surrounding landscape. Due to the difference in the area and location of water, the bridge in the Korean palace is more focused on the convergence of the surrounding buildings and plants, while the bridge in the Chinese palace is more concerned about the harmony of hydration. Fourth, the decoration places importance on the artistry and aesthetics of both the bridges in Korea and China. There is a difference in style in the same type of decoration due to culture.

Proposal for Amendment of the Basic Environmental Policy Act ('BEPA') Article 31 (환경정책기본법 제31조 무과실책임규정의 개정방안)

  • Koh, Moon-Hyun
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.125-147
    • /
    • 2009
  • The Basic Environmental Policy Act (BEPA) (Law No. 4257 effective 1. August 1990) sets forth the basic policies and administrative framework for environmental preservation, leaving more detailed regulations, and emission controls to separate laws targeting air, water, and solid waste, etc. The BEPA Article 31 adopts an unprecedented strict liability standard for damages as an absolute liability. The BEPA Article 31 provides for liability as follows. If a company is alleged to have caused damage through pollution of the environment, it will be liable for damages unless it can show that the pollution did not cause damages, or that it did not actually cause pollution. If the company did cause pollution, and if the pollution is the cause for the damages in question, the company will be liable irrespective of whether it was negligent or otherwise at fault. If there are two or more companies involved in the pollution, but it is unclear which company caused the damages, all of the companies will be jointly and severally liable for the damages. In this paper, the author attempts to uncover the problems of BEPA Article 31 and then seeks desirable amendments by comparing it to the German Environmental Liability Act. First, it will be necessary to provide definitions of 'companies etc.'. Second, it will be necessary to enumerate the kinds of company facilities. Third, it will be necessary to provide exclusionary clauses on material damages. Fourth, it will be necessary to show 'presumption of cause and effect'. Fifth, it will be necessary to provide a clause on 'right to information'. Sixth, it will be necessary to provide a clause for force majeure. Seventh, it will be necessary to take measures to secure abundant liability for damages which can be caused by the owner of the facility, the potential polluter. Finally, it is appropriate that Korea now legislate an Environmental Liability Act akin to the German Environmental Liability Act.

  • PDF

Analysis of Temperature Changes in Greenhouses with Recirculated Water Curtain System (순환식 수막하우스의 수온에 따른 플라스틱 온실 내 온도변화 분석)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Pyo, Hee-Young;Jeong, Jae-Woan;Kim, Yong-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.93-99
    • /
    • 2015
  • The purpose of this study was to determine the appropriate temperature for water curtain in greenhouses equipped with recirculated water curtain system. The study analyzed the changes in air temperature in non-heated greenhouses for strawberry cultivation based on outdoor temperature, water curtain temperature and night time. Three greenhouse units were used for this study: The first unit was assigned as a control (no water curtain system), two other greenhouses were equipped with recirculated water curtain system with water curtain temperatures of $10^{\circ}C$ and $15^{\circ}C$, respectively. Analysis showed that the indoor temperatures were directly correlated with the outdoor temperature in all experimental greenhouses. Heat insulating effect of $15^{\circ}C$ water curtain was increased by $1.3^{\circ}C$ compared to that in $10^{\circ}C$ water curtain system. The $15^{\circ}C$ water curtain treatment showed the highest average temperature and less temperature variation in comparison with control and $10^{\circ}C$ water curtain treatment. To maintain indoor temperature at $5^{\circ}C$, water curtain temperature of $10^{\circ}C$ was suitable when outdoor minimum and average temperatures were -1.3 and $1.5^{\circ}C$, and water curtain temperature of $15^{\circ}C$ was suitable when outdoor minimum and average temperatures were -4.7 and $-0.2^{\circ}C$, respectively. The highest temperature in greenhouses according to measurements in different periods of night time was observed after sunset (18:30-20:30), and the lowest temperature before sunrise (05:00-07:00). Water curtain maintained a target indoor temperature by acting as a layer of heat transfer insulator which decreased heat loss from greenhouses. Therefore, water temperature in recirculating water curtain systems should be determined by considering outdoor temperatures, changes in temperature at different periods of night time, and cultivated crop.

Experimental Study on the Characteristics of Ground Heat Exchange in Heating Greenhouses (난방 온실의 지중열 교환 특성에 관한 실험적 연구)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • The calculation method of ground heat exchange in greenhouses has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the soil temperature distribution and the soil heat flux in three plastic greenhouses of different size and location during the heating period. And then the calculation methods of ground heat exchange in greenhouses were reviewed. The soil temperature distributions measured in the heating greenhouse were compared with the indoor air temperature, the results showed that soil temperatures were higher than room temperature in the central part of greenhouse, and soil temperatures were lower than room temperature in the side edge of greenhouse. Therefore, it is determined that the ground heat gain in the central part of greenhouse and the perimeter heat loss in the side edge of greenhouse are occurred, there is a difference depending on the size of greenhouse. Introducing the concept of heat loss through the perimeter of building and modified to reflect the size of greenhouse, the calculation method of ground heat exchange in greenhouses is considered appropriate. It was confirmed that the floor heat loss measured by using soil heat flux sensors increased linearly in proportion to the temperature difference between indoor and outdoor. We derived the reference temperature difference which change the direction of ground heat flow and the perimeter heat loss factor from the measured heat flux results. In the heating design of domestic greenhouses, reference temperature differences are proposed to apply $12.5{\sim}15^{\circ}C$ in small greenhouses and around $10^{\circ}C$ in large greenhouses. Perimeter heat loss factors are proposed to apply $2.5{\sim}5.0W{\cdot}m^{-1}{\cdot}K^{-1}$ in small greenhouses and $7.5{\sim}10W{\cdot}m^{-1}{\cdot}K^{-1}$ in large greenhouses as design standard data.

Effect of White and Blue Wind Net Shading on the Quality of 'Fuji' and 'Hongro' Apple Fruits (백색 및 청색 방풍망 차광 처리가 '후지', '홍로' 사과 과실의 품질에 미치는 영향)

  • Kang, Kyeong-Jin;Seo, Jeong-Hak;Yoon, Hong-Ki;Seo, Jeong-Seok;Joo, Jung-Il;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.120-129
    • /
    • 2020
  • In Yesan-gun, Korea's main apple-producing region, the area of apple cultivation and yield are declining. In particular, the worsening quality of fruits due to unusually high temperatures amid recent climate change has also become a major challenge for apple orchards located on flatlands. The objective of this research is to investigate quality changes of apples according to different growing environments, depending on the shade of the sun, by covering the trees with different colors of wind nets. A white and blue wind nets with a hole size of 2 × 2 mm is installed on two experimental trees, 17-year-old 'Fuji' and 'Hongro', which are planted 1.5 m × 3.5 m in the north-south direction. Treatment of wind nets effectively lowered fruit surface temperature regardless of apple variety. When measuring the temperature of the fruit surface at 2 pm, the temperature of the air was 34.8℃, but the 'Fuji' of the untreated blocks was the highest at 40.0℃, while the blue wind net and the white wind net were significantly lower at 34.9℃ and 36.6℃, respectively. In 'Hongro', the results showed that the surface temperature was effectively lowered by recording 38.3℃ for the blue wind net and 38.5℃ for the white wind net treatment when the untreated one was 44.2℃. According to the color difference in 'Fuji', the skin redness (a) was the lowest with untreated control at 16.5, but the blue and white wind net treatment higher at 18.0 and 19.3, respectively. In 'Hongro', the white wind net treated fruit also showed a much higher skin redness than the untreated control of 28.1, showing much higher a of 34.9. Sunburn damage in 'Fuji' apples amounted to 9.4% in untreated control. However, the blue and white wind net treatment revealed to 3.8% and 4.2%, respectively. In 'Hongro', those damage in the fruits treated with blue or white wind net, accounted for only 8.8% and 12.4%, respectively, significantly lower than 28.8% occurrence of untreated one. And, these results were understood to be the result of low UV radiation being blocked by the treatment of wind nets.

Physico.chemical Properties of Peatmoss and Coir Dust Currently Used as Root Medium Components for Crop Production in Korean Plant Factories (국내에서 식물공장용 배지 재료로 유통되는 피트모스와 코이어 더스트의 물리.화학적 특성)

  • Shin, Bo Kyoung;Son, Jung Eek;Choi, Jong Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.362-371
    • /
    • 2012
  • Objective of this research was to secure the information on physical and chemical properties of peatmoss and coir dust. To achieve this, 6 kinds of peatmoss and 10 kinds of coir dust currently used in the country as the root medium components in plant factories were collected and analysed. The mean ${\pm}$ standard deviation (SD) of total porosity and container capacity in peatmoss and coir dust were $79.6{\pm}5.04$ and $83.6{\pm}6.18%$, and $69.9{\pm}10.17$ and $65.9{\pm}3.46%$, respectively. These indicate that peatmoss has higher water holding capacity than coir dust and the characteristics are highly varied among peatmoss. The 4 out of 5 kinds of peatmoss had lower than 10%, but coir dust had 12~26%, of air-filled porosity. The percentage of easily available water and buffering water in peatmoss and coir dust was 18~22 and 11~16% and 9~13 and 5.5~7.5%, respectively. These results indicate that precise irrigation is required when coir dust is used as the root medium. The ranges of pH and electrical conductivity (EC) were 3.46~4.17 and $0.137{\sim}0.253dS{\cdot}m^{-1}$ in peatmoss and 5.31~6.48 and $0.250{\sim}0.1.580dS{\cdot}m^{-1}$ in coir dust. However, $0.563{\pm}0.83dS{\cdot}m^{-1}$ in mean ${\pm}$SD of coir dust EC indicates that it is higher than that of peatmoss, and the coir dust are highly varied in EC. The cation exchange capacity of peatmoss was 3 to 4 times as high as that of coir dust. The coir dust had higher $NO_3$ and $PO_4$ and lower $NH_4$ than peatmoss. The K and Na concentrations in coir dust were extremely high indicating that these ions caused the rising in EC. The percentage of hot water and alkali extracts of peatmoss were 6.67~16.37 and 0~38%, whereas those of coir dust were 30.0~65.1 and 23.1~70.3%. These results mean that possible existence of growth inhibiting materials in coir dust.

Effect of Shading Methods on Growth and Fruit Quality of Paprika in Summer Season (파프리카 여름재배시 차광방법이 생육과 과실특성에 미치는 영향)

  • Ha, Jun Bong;Lim, Chae Shin;Kang, Hyo Yong;Kang, Yang Su;Hwang, Seung Jae;Mun, Hyung Su;An, Chul Geon
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.419-427
    • /
    • 2012
  • This study was carried out to investigate the effect of two shading methods, shading agent spray on the glasshouse and internal shading screen treatment, on the growth and fruit quality of paprika (Capsicum annuum L. 'Cupra' and 'Coletti') in summer season cultivation. In the shading agent treatment, a commercial shading agent diluted with water at a ratio of 1 : 4 was sprayed on the roof of a glasshouse. In the internal shading screen treatment, a 10~20% shaded screen was used during the day time when the sun radiation was greater than $700W{\cdot}m^{-2}$. Compared to the unshaded control, photosynthetic photon flux density (PPFD) decreased in the greenhouse in the shading agent (SA) and shading screen (SS) treatments by 20% and 30%, respectively. Lower air temperatures and higher relative humidities were observed in the SA than in both the control and the SS treatment. Time to reach the break point of humidity deficit $8g{\cdot}m^{-3}$ was 2 hours late in the SA than in both the control and the SS treatment. Compared to control, both the SA and the SS treatments showed lower instantaneous temperatures of leaf, fruit, and flower by $2^{\circ}C$, $5^{\circ}C$ and $3^{\circ}C$, respectively. There were no differences in number of branches, stem diameter, and leaf size among treatments although both shading treatments promoted plant height in both cultivars. Botrytis infection ratio declined with the SA treatment by 14.7% in 'Cupra' and 22.1% in 'Coletti' as compared to that in the control. Shading increased fruit size in both cultivars, whereas no differences were observed in the number of locules and thickness of fruit tissue among treatments. Shading treatment increased mean fruit weight by a range of 10 to 15 g per fruit, while it decreased soluble solids contents as compared to that in the control. Similar Hunter values were observed among treatments, while fruit firmness increased slightly in shading treatments. Compared to the control, shading treatments improved marketable fruits by 11.7~22.6% and increased the number of fruits per plant by 4~9.2 in both 'Cupra' and 'Coletti'. The results of this study indicate that shading agent application on the roof of glasshouse would be one of the most effective options to reduce heat stress imposed on the paprika crop in summer cultivation, resulting in improved crop growth and fruit yield.

Utilization of $CO_2$ Influenced by Windbreak in an Elevated Production System for Strawberry (딸기 고설재배시설에서의 이산화탄소 농도 유지를 위한 방풍막 설치 효과)

  • Kim, Y.-H.;Lee, I.-B.;Chun, Chang-Hoo;Hwang, H.-S.;Hong, S.-W.;Seo, I.-H.;Yoo, J.-I.;Bitog, Jessie P.;Kwon, K.-S.
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.29-39
    • /
    • 2009
  • The influence of windbreak to minimize the ventilation velocity near the plant canopy of a greenhouse strawberry was thoroughly investigated using computational fluid dynamics (CFD) technology. Windbreaks were constructed surrounding the plant canopy to control ventilation and maintain the concentration of the supplied $CO_2$ from the soil surface close to the strawberry plants. The influence of no windbreak, 0.15 m and 0.30 m height windbreaks with varied air velocity of 0.5, 1.0 and 1.5 m/s were simulated in the study. The concentrations of supplied $CO_2$ within the plant canopy of were measured. To simplify the model, plants were not included in the final model. Considering 1.0m/s wind velocity which is the normal wind velocity of greenhouses, the concentrations of $CO_2$ were approximately 420, 580 and 653 ppm ($1{\times}10^{-9}kg/m^3$) for no windbreak, 0.15 and 0.30 m windbreak height, respectively. Considering that the maximum concentration of $CO_2$ for the strawberry plants was around 600-800 ppm, the 0.30 m windbreak height is highly recommended. This study revealed that the windbreak was very effective in preserving $CO_2$ gas within the plant canopy. More so, the study also proved that the CFD technique can be used to determine the concentration of $CO_2$ within the plant canopy for the plants consumption at any designed condition. For an in-depth application of this study, the plants as well as the different conditions for $CO_2$ utilization, etc. should be considered.