• Title/Summary/Keyword: Air Data Calibration

Search Result 72, Processing Time 0.023 seconds

Reliability Analysis of the GCM Data Downscaling Methods for the Climate-Induced Future Air Temperature Changes in the Coastal Zone (연안 해역의 미래 기온변화 예측을 위한 GCM 자료 Downscaling 기법의 신뢰수준 분석)

  • Lee, Khil-Ha;Cho, Hong-Yeon;Cho, Beom-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.34-41
    • /
    • 2008
  • Future impact of anthropogenic climate-induced change on ecological regime has been an issue and information on water temperature is required for estimating coastal aquatic environment. One way to induce water temperature is to relate water temperature to air temperature and GCM is able to provide future air temperature data to do this. However, GCM data of low spatial resolution doesn't incorporate local or sitespecific air temperature in need of application, and downscaling processes are essential. In this study, a linear regression is used to relate nationally averaged air temperature to local area for the time period of 2000-2005. The RMSE for calibration (2000-2005) is 1.584, while the RMSE for validation is 1.675 for the year 2006 and 1.448 for the year 2007. The NSC for calibration (2000-2005) is 0.962, while the NSC for validation is 0.955 for the year 2006 and 0.963 for the year 2007. The results show that the linear regression is a good tool to relate local air temperature to nationally averaged air temperature with $1.0{\sim}2.0^{\circ}C$ of RMSE. The study will contribute to estimate future impact of climate-induced change on aquatic environment in Korean coastal zone.

Evaluation of experimental reliability for trace-quantity of gaseous VOC working standards based on thermal desorption analysis (극미량 휘발성유기화합물질의 기체상 표준시료 조제와 열탈착분석방식에 기초한 분석안정도의 평가)

  • Park, Shin-Young;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.553-558
    • /
    • 2006
  • In this study, an attempt was made to measure uncertainties involved in the VOC analysis for the VOC working standards prepared by a dilution technique using Tedlar bags. For this purpose, VOC standard gases of benzene, toluene, xylene, and styrene were prepared at four different concentrations (4, 8, 20, and 40 ppb). These standard samples were then loaded on to the GC system equipped with air server/thermal desorption (AS/TD) system. Each of these four standard concentrations was analyzed individually to derive their respective calibration results. These calibration data sets were then compared across four different compounds. According to this comparison, differences in calibration patterns were moderately insignificant within the selected concentration range of 4~40 ppb. It was also observed that the loss of styrene standard was fairly high compared to other VOCs investigated simultaneously. The results of our study suggest that the analytical uncertainty associated with the preparation of VOC starndard gas using a dilution technique can be assessed in a fairly reasonable manner for samples with a narrow concentration range.

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence (아세톤 형광을 이용한 공연비 측정 기법 연구)

  • Park Seungjae;Huh Hwanil;Oh Seungmook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

Development of an End-use Analysis Tool for Existing Buildings Based on Energy Billing Data (고지데이터 기반 기존 건축물의 용도별 에너지사용 현황분석 툴 개발)

  • Kong, Dong-Seok;Park, Jung-Min;Jang, Yong-Sung;Lee, Keon-Ho;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.128-136
    • /
    • 2015
  • Reducing the building energy consumption has become one of the most important issues. However, the current engineering and technological involvement in energy analysis has been relatively low in the existing buildings. In the existing buildings, end-use analysis must be accompanied to calculate the exact amount in energy savings and such analysis should be conducted based on the energy billing data or measurement data by calibration process. Mostly, detailed energy simulation programs have been proposed for the analysis but, it is difficult to utilize them due to realistic problems. In this paper, we developed an end-use analysis tool that have input function for energy audit data and two case studies were conducted in the real-life office buildings located in Seoul, Korea. Mean Bias Error (MBE) and Coefficient of Variation of Root-Mean- Squreaed-Error (CV(RMSE)) are used for the criteria of comparison. Each index was calculated by using monthly utility bills of electricity and gas consumption. Results showed that MBE and CV (RMSE) represented with acceptable values of -0.1% and 5.7% respectively.

Partial Least Squares Analysis on Near-Infrared Absorbance Spectra by Air-dried Specific Gravity of Major Domestic Softwood Species

  • Yang, Sang-Yun;Park, Yonggun;Chung, Hyunwoo;Kim, Hyunbin;Park, Se-Yeong;Choi, In-Gyu;Kwon, Ohkyung;Cho, Kyu-Chae;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.399-408
    • /
    • 2017
  • Research on the rapid and accurate prediction of physical properties of wood using near-infrared (NIR) spectroscopy has attracted recent attention. In this study, partial least squares analysis was performed between NIR spectra and air-dried specific gravity of five domestic conifer species including larch (Larix kaempferi), Korean pine (Pinus koraiensis), red pine (Pinus densiflora), cedar (Cryptomeria japonica), and cypress (Chamaecyparis obtusa). Fifty different lumbers per species were purchased from the five National Forestry Cooperative Federations of Korea. The air-dried specific gravity of 100 knot- and defect-free specimens of each species was determined by NIR spectroscopy in the range of 680-2500 nm. Spectral data preprocessing including standard normal variate, detrend and forward first derivative (gap size = 8, smoothing = 8) were applied to all the NIR spectra of the specimens. Partial least squares analysis including cross-validation (five groups) was performed with the air-dried specific gravity and NIR spectra. When the performance of the regression model was expressed as $R^2$ (coefficient of determination) and root mean square error of calibration (RMSEC), $R^2$ and RMSEC were 0.63 and 0.027 for larch, 0.68 and 0.033 for Korean pine, 0.62 and 0.033 for red pine, 0.76 and 0.022 for cedar, and 0.79 and 0.027 for cypress, respectively. For the calibration model, which contained all species in this study, the $R^2$ was 0.75 and the RMSEC was 0.37.

Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design (현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정)

  • Cho, Myung-Hwan;Kim, Nakseok;Shim, Jaepill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.433-439
    • /
    • 2011
  • The frost depth(frost penetration) is used to install anti-frost heave layers in pavement designs. The freezing index is calculated by an annual accumulated value of multiplying the period of time with temperatures below zero, and the corresponding temperature. Therefore, the DAAT(daily average air temperature) calculation method may play an effect on the FI(freezing index). The Weather Observatory used to supply 4 average air temperatures per day, but currently supplies 8 per day. With this study, we divided the southern part(below FI=$350^{\circ}C{\cdot}day$) of the Korean peninsula into 6 areas according to site conditions(low embankment, embankment-cutting slope, and the cutting slope) and established a field measurement system for 15 positions to check the effects on the result of FI according to differing DAAT calculation methods. The air temperatures obtained by the field measurement system was used to calculate and compare the FI. As a result, the freezing index calculated based on the $DAAT_4(T_4)$ is normally greater by 3% than the one on $DAAT_8(T_8)$. In addition, the calibration equation for the freezing index using air temperatures was proposed through the research.

Measures to Improve the Efficiency of the Portable Air Quality Measurement System

  • CHOI, Jong-Sun;CHO, Dong-Myung;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.3
    • /
    • pp.27-41
    • /
    • 2022
  • Purpose: In this study, pollutants generated in industrial areas were measured using a Portable Air Quality Measurement System(PAQMS). This study intends to examine in detail improvement measures and operational capabilities to operate a more efficient PAQMS. Research design, data and methodology: This study compares and analyzes the measurement values of the PAQMS and the measurement values of the national air quality measurement network. It is intended to develop a PAQMS corresponding to the data of the national measurement network by minimizing the errors that occur during comparative measurement and analysis and supplementing and improving the problems that occur during the current equipment calibration. Results: A PAQMS is an essential equipment for faster and more accurate measurement and analysis of pollutants in case of untimely measurement and civil complaints due to Micro Climate(local weather and environmental influences). Currently, there are many atmospheric measurement equipment in Korea, but only equipment for each item is produced and sold. Currently, these devices on the market must satisfy various conditions such as stable power, temperature, and humidity to calculate accurate measurement values. Conclusions: Therefore, there is no equipment that satisfies the conditions for performing detailed measurement in the field where accurate measurement is required. In this study, these field work conditions and contents for stable measurement were mentioned in the text.

Capillary Hysteresis Model in Unsaturated Flow : State of the Art

  • Park, Chan-Kun;Sonu, Jun-Ho
    • Korean Journal of Hydrosciences
    • /
    • v.4
    • /
    • pp.33-49
    • /
    • 1993
  • The Purpose of this study is to classify existing hysteresis models and to discuss a possibility of a new type of the hysteresis model. The existing hysteresis models are classified into three types: the interpolation model, the scaling model and the domain model, of which only domain model is to simulate hysteresis curves based on the theoretical approach, It is useful to develop a hysteresis model that requires only one branch of hysteresis curves for the model calibration because obtaining hysteresis curves by experiments is expensive and time-concept by many investigators, however their models are not successful to accurately simulate real data of Rubicon Sandy Loam and Dune Sand. There is a possibility that a new model is based on the dependent domain concept considering the weighting factor, $P_a$($\theta$), which accounts for the pore blockage effect against air entry. Conclusively, a new model where the weighting factor $P_a$($\theta$) in Model III-1 (Mualem, 1984) reduces to a known variable through an appropriate method is an alternative model which required only one branch of main curves for the model calibration.

  • PDF

The study on the combustion characteristics of a planar flame burner as a calibration source of laser diagnostics (연소진단 검정원으로써 평면화염 버너의 연소특성 연구)

  • Gil,Yong-Seok;Jeong, Seok-Ho;Lee, Byeong-Jun;Han, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3355-3360
    • /
    • 1996
  • To provide standard data of temperature and species concentration in a flame for calibrating the laser based combustion diagnostics, we investigated combustion characteristics of a flat flame burner(Mckennar Product). For various stoichiometric ratios we measured temperature and concentration of OH in the premixed methane/air flame with Coherent anti-Stokes Raman spectroscopy and laser induced fluorescence technique, respectively. Assuming the chemical equilibrium condition at the measured temperature, the mole fraction of the OH radical in the flame was obtained and compared with numerical analysis.

Capillary Hysteresis Model in Unsaturated Flow - Development of Model - (비포화 흐름에서 모세관 이력현상 모형의 고찰 - 모형의 개발 -)

  • Park, Chang Kun;Sonu, Jung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.131-140
    • /
    • 1993
  • A new model which requires one branch of main curves for the model calibration is developed based on the assumption that the weighting factor accounting for the pore blockage effect against air entry, $P_a({\theta})$, in Mualem's Model III-1 has a linear relation to the dimensionless pore radius r. The proposed model simulates experimental data more accurately than existing models which require one branch of main curves for the model calibration. Previous study showed that Model III-1 is the most appropriate model among domain models which require two branches of main curves for the model calibration. In comparison of the proposed model with Model III-1, both simulate hysteresis curves with almost the same accuracy. The proposed model can be applied efficiently in analyzing the unsaturated flow.

  • PDF