아세톤 형광을 이용한 공연비 측정 기법 연구

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence

  • 박승재 (충남대학교 항공우주공학과 대학원) ;
  • 허환일 (충남대학교 항공우주공학과) ;
  • 오승묵 (한국기계연구원)
  • 발행 : 2002.08.01

초록

Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

키워드