• Title/Summary/Keyword: Air Column

Search Result 359, Processing Time 0.028 seconds

Spalling Resistance of High Strength Concrete Using Non-Stripping Form (비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지)

  • You, Ji-Young;Han, Chang-Pyung;Jee, Suk-Won;Han, Min-Cheol;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.865-868
    • /
    • 2008
  • As a part of a series of study, this study reviewed the fire proof characteristics of high performance concrete RC column members using non-stripping form that accompanied metal lath lateral confinement to prevent spalling of high performance concrete which is increasingly used recently, and the results are as follows. Flow and air amount both satisfied target range, and compressive strength, over 80MPa at age 28 days, showed high strength range. As for spalling characteristics, in the case of plain in which no fiber is mixed, severe spalling occurred, and in the case of 0.05% nylon("NY" hereinafter)+polypropylene("PP" hereinafter) fiber mixture, only surface area experienced partial spalling. Regarding non-stripping form changes, both non-stripping 25-20 and non-stripping 50-20 experienced spalling at finish material area, and non-stripping 50-20 showed better spalling proof performance than non-stripping 25-20. In the case of non-stripping 50-40, spalling was prevented, and while mass reduction rate was less than 10%, its temperature hysteresis showed the most excellent fire proof performance with base metal surface area maximum temperature $376.1^{\circ}C$.

  • PDF

A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society (18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색)

  • Chung, Jung-Nam
    • Journal of architectural history
    • /
    • v.27 no.3
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.12 no.11
    • /
    • pp.1167-1171
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRTAP) of Europe. A method of the gas chromatographicmass spectrometric (GCMS) determination of PAHs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PAHs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PAHs sewage sludge samples varied from 2.44 to 4.82 $\mu\textrm{g}$/g. Concentration of emission carcinogen PAHs(PAHcarc), such as Benzo(a)anthracene, Benzo(b)f1uoranthene, Benzo(k)f1uoranthene, Benzo(a)pyrene, Dibenzo(a,h)anthracene and Indeno( 1,2,3-cd)pyrene ranged from 0.62 to 1.03 $\mu\textrm{g}$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PAHs and $\Sigma$PAHcarc from sewage treatment plants had emitted to environment by several pathway. The highest amount of emission to the environment was remarked in the ocean dumping(PAHs and $\Sigma$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year, respectively).

Study of Application of Impulse Turbine with Staggered Blades to Improve the Performance for Wave Energy Conversion (파력발전용 임펄스터빈의 효율 향상을 위한 Staggered Blade의 적용에 대한 연구)

  • Moon, Jae-Seung;Shin, Seung-Ho;Hyun, Beom-Soo;Kim, Gil-Won;Hong, Key-Yong
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.845-852
    • /
    • 2007
  • An OWC-type Wave Energy Conversion passes through 3 steps energy conversion process. This paper deal with the impulse turbine with staggered blade to improved performance by numerical analysis using commercial CFD code, FLUENT Maximum value of axial airflow velocity during exhalation is higher than that during inhalation This paper deal with special-type of Impulse Turbine so-called "Staggered Blade" for more efficiency to making air flow direct to on pressure side. Also, this paper has proposed special-type turbine with self-pitched blade more efficient.

The Characteristics of the Appearance and Health Risks of Volatile Organic Compounds in Industrial (Pohang, Ulsan) and Non-Industrial (Gyeongju) Areas

  • Jung, Jong-Hyeon;Choi, Bong-Wook;Kim, Mi-Hyun;Baek, Sung-Ok;Lee, Gang-Woo;Shon, Byung-Hyun
    • Environmental Analysis Health and Toxicology
    • /
    • v.27
    • /
    • pp.12.1-12.8
    • /
    • 2012
  • Objectives: The aim of this study was to identify the health and environmental risk factors of air contaminants that influence environmental and respiratory diseases in Gyeongju, Pohang and Ulsan in South Korea, with a focus on volatile organic compounds (VOCs). Methods: Samples were collected by instantaneous negative pressure by opening the injection valve in the canister at a fixed height of 1 to 1.5 m. The sample that was condensed in $-150^{\circ}C$ was heated to $180^{\circ}C$ in sample pre-concentration trap using a 6-port switching valve and it was injected to a gas chromatography column. The injection quantity of samples was precisely controlled using an electronic flow controller equipped in the gas chromatography-mass spectrometer. Results: The quantity of the VOC emissions in the industrial area was 1.5 to 2 times higher than that in the non-industrial area. With regards to the aromatic hydrocarbons, toluene was detected at the highest level of 22.01 ppb in Ulsan, and chloroform was the halogenated hydrocarbons with the highest level of 10.19 ppb in Pohang. The emission of toluene was shown to be very important, as it accounted for more than 30% of the total aromatic hydrocarbon concentration. Conclusions: It was considered that benzene in terms of the cancer-causing grade standard, toluene in terms of the emission quantity, and chloroform and styrene in terms of their grades and emission quantities should be selected for priority measurement substances.

Study of apartment plan technology adopting structural element of Hanok (공동주택에 적용 가능한 한옥 평면기술에 관한 연구)

  • Park, Kyung Hyun;Roh, Young-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6366-6371
    • /
    • 2014
  • This study examined the structural elements of Korean-style houses (Hanok) and proposed formula accounting for their similar patterns and regular behavior. The design of modern apartment buildings adopts many aesthetic elements from Hanok but those are only for interior decoration. In this study, the projected Hanok eaves were examined in terms of the length of solar insolation. Leaning pillars toward the inside of the building were analyzed in detail not only for the front and back pillar, side pillar, but also the corner pillar. This study also suggested a design element from the Hanok structure, such as the elevated balcony, porch flooring, and inner garden in porch area. In addition, the new apartment plan improved air circulation, ventilation and natural lighting.

Flvonoids and Their Glycosides from the Bark of Salix rorida (분버들(Salix rorida) 수피의 후라보노이드 및 배당체 화합물)

  • Ham, Yeon-Ho;Bae, Young-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.56-62
    • /
    • 2002
  • The air-dried bark of Salix rorida was extracted with acetone-water(7:3, v/v) and its extractives were concentrated with a vacuum evaporator. The extractives were fractionated with a series of n-hexane, chloroform, ethylacetate(EtOAc) and water on a separatory funnel. Each fraction was freeze-dried to give some dark brown powder. The EtOAc and water soluble fractions were chromatographed on a Sephadex LH-20 column using a series of aqueous methanol and ethanol-hexane mixture as eluents. The isolated compounds were tested with a cellulose TLC developed with TBA and 6% acetic acid and then visualized on UV lamp or sprayed with vanillin-HCl-EtOH. The purified compounds were flavonoids and their glycosides as follows:(+)-catechin, naringenin, salipurposide, aromadendrin, isosalipurposide, aromadendrin-7-O-𝛽-D-glucopy- ranoside and taxifolin-7-O-𝛽-D-glucopyranoside. The structures of each compounds were confirmed by 1H-NMR, 13C-NMR and mass spectra.

Dynamic Shear Properties of Nak-Dong River Sand Determined by Resonant Column/Torsional Shear Test (공진주/비듦전단시험을 이용한 낙동강모래의 동적전단변형특성)

  • Kim, Jin-Man;Park, Yo-Hwan;Lim, Suck-Dong
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.5-15
    • /
    • 2009
  • Dynamic shear properties of Nak-Dong river sand were investigated to build a soil property database for Nak-Dong delta region. Samples were taken from the estuary and the midstream of the river. Laboratory specimens were prepared by air pluviation method, and were tested by using RC/TS apparatus at various confining stresses, relative densities and numbers of cycles. Shear modulus reduction and damping curves were developed using Ramberg-Osgood and Modified Hyperbolic Models. The developed curves, compared to those reported by other investigators, show only a slight difference. The outcome of this RC/TS experiments can be very important resources when accessing the dynamic response of sandy soils in Nak-Dong delta region in the future.

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

The Volcanic Eruption Velocity and Tumulus of Jeju Island Controlled by the Natural Intelligence (자연 지능 제어에 의한 제주도의 화산 폭발 속도와 튜물러스)

  • Lee, Seong kook;Lee, Moon Ho;Kim, Jeong Su
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.493-499
    • /
    • 2022
  • This paper reports the results of the eruption of a volcano on Jeju Island at a certain rate, and the tumulus formed after the eruption and the basalt that erupted from the middle of Mt. Halla washed up to the sea. We analyzed the speed when basalt underground magma breaks through the neutral zone on the ground with an absolute temperature of about 1000K and explodes at an absolute temperature of 1200K at an altitude of 1950m. The density of combustion gas becomes smaller than the surrounding air due to the plume volcanic eruption, which is the heat flow of the flame column due to buoyancy, and buoyancy is generated and an updraft is formed. Flame pillars are classified as continuous, intermittent, and buoyant flame zones. As the speed of the flame pillar of Mt. Halla (1950m) falls from the highest point it has risen, potential energy is converted into kinetic energy and is caused by the flow of fluid, solving these two equations equal, the volcanic eruption velocity is 87.5 m/s. At this time, the density of magma is inversely proportional to the temperature. Geomunoreum (456m) had an explosion speed of 42.6m/s.