• Title/Summary/Keyword: Adhesion Measurement

검색결과 239건 처리시간 0.031초

접착력의 측정 (Measurement of Adhesion)

  • 김성룡;이호영
    • 접착 및 계면
    • /
    • 제4권3호
    • /
    • pp.21-32
    • /
    • 2003
  • 본 원고에서는 전에 발표된 동반 논문[한국 접착 및 계면학회지, 3권4호(2002)]과 연관된 여러 가지 접착력 측정방법에 관하여 살펴보았다. 먼저 이상적인 접착력 측정방법에 관하여 살펴보았고, 그 다음으로 기계적 방법, 비기계적 방법 그리고 기타 방법의 3가지로 종류의 접착력 측정방법들을 소개하였다.

  • PDF

연골세포 부착력 평가 (Adhesion Strength Measurement of Rabbit Knee Chondrocyte)

  • 이권용;박상국;;박종철
    • Tribology and Lubricants
    • /
    • 제21권5호
    • /
    • pp.236-240
    • /
    • 2005
  • In order to prepare for the suitable surfaces of implants or medical devices, quantitative evaluation of adhesion between cells and biomaterials is essential. To better understand adhesion formation between cells and biomaterials, we used the cytodetachment technique which measures the adhesive force of a single cell through changing the, culture time and detachment speed. The results showed that the adhesive force could be affected by the culture time of cells on the surface of materials and the detachment speed. Moreover, there was a large discrepancy among the adhesion strength measured by similar techniques conducted on the different cells and substrates. It can be 'concluded that the variation of the force measurement technique can seriously alter the level of the force required to detach a cell on the surface of materials.

고탄성 고분해능을 갖는 응착력 측정장치의 개발 (Development of Adhesion Force Measurement Apparatus with High Stiffness and High Resolution)

  • 김규성;윤준호
    • 한국정밀공학회지
    • /
    • 제24권3호
    • /
    • pp.140-146
    • /
    • 2007
  • To understand adhesive phenomena, we need to get force curve between two surfaces. And it is said that high stiffness force analysis system is needed to get precise force curve and more information of the surfaces. Usually the stiffness of the force measurement system is under the order of 10N/m. The stiffer force measurement system, however, results in more information on the surface, because higher stiffness lead to the wider range of force curves, secondly because the force curve obtained through the stiffer one describes more precise relationship between relative tip-sample separation and interaction force. In this paper, considering for stiffness and resolution, the cantilever was designed and we made adhesion force measurement apparatus with high stiffness and high resolution, so we measured adhesive force between Ag-ball and wafer.

Johnson-Kendall-Roberts (JKR) 기법을 이용한 표면 에너지 및 고유접착에너지 측정 (Measurement of Surface Energy and Intrinsic Work of Adhesion Using Johnson-Kendall-Roberts (JKR) Technique)

  • 이대호;이동윤;조길원
    • 접착 및 계면
    • /
    • 제5권3호
    • /
    • pp.18-22
    • /
    • 2004
  • 본 실험에서는 Johnson-Kendall-Roberts (JKR) 기법을 이용하여 고체물질의 표면에너지 및 두 물질 사이의 고유접착에너지를 측정하였다. JKR 기법의 원리는 기본적으로 접촉역학(contact mechanics)에 기본을 두고 있으며 이를 통하여 기존의 접촉각 측정 방식을 통한 고체 표면에너지 측정 및 peel test와 같은 고전적인 방법을 통한 접착에너지의 측정에서의 한계점을 극복할 수 있는 새로운 방법으로 받아들여지고 있다. 본 연구에서는 polydimethylsiloxane (PDMS)를 이용하여 표면에너지를 측정함으로써 JKR 기법을 통한 측정 결과와 이의 응용가능성에 대해 알아보고자 하였다.

  • PDF

Adhesion of clay to metal surface; Normal and tangential measurement

  • Basmenj, Amir Khabbazi;Ghafoori, Mohammad;Cheshomi, Akbar;Azandariani, Younes Karami
    • Geomechanics and Engineering
    • /
    • 제10권2호
    • /
    • pp.125-135
    • /
    • 2016
  • Adhesion in geotechnical engineering is the interaction between cohesive soil and a solid surface which can cause clogging in mechanized tunnelling through clayey formations. Normal piston pull out and modified direct shear tests were performed on clayey soil samples to determine which type of adhesion stress, normal or tangential, could be most effectively measured. Measured values for normal adhesion ranged from 0.9 to 18 kPa. The range of tangential adhesion was 2.4 to 10 kPa. The results indicate normal adhesion results were more accurate than those for the modified direct shear test that measure tangential adhesion. Direct shear test on identical samples did not show any correlation between measured cohesion and normal adhesion values. Normal adhesion values have shown significantly meaningful variation with consistency index and so are compatible with the base of field clogging assessment criteria. But tangential adhesion and cohesion were not compatible with these assessment criteria.

구두용 접착제의 품질 특성에 관한 연구(I) -여성 가죽구두- (A Study on the Quality Characteristics of Leather Shoe Adhesives(I) -Ladies' Leather-shoe-)

  • 서교택;이상신
    • 산업경영시스템학회지
    • /
    • 제23권54호
    • /
    • pp.137-144
    • /
    • 2000
  • The chloroprene adhesive for ladies' shoe-making applied by the cementing method in KS G 3116 has been evaluated.. For the quality test of adhesive for pump whole cut vamp using chloroprene adhesive, general property and adhesion strength were measured and duration for environmental exposure was tested. Also, a list of experiments for field application was prepared. In case of adhesion-strength measurement,, the KS G 3116 method of peel strength at end of toe was found to be reasonable by measurement through a whole length, toe to heel seat on feather edge.

  • PDF

FOWLP 적용을 위한 Cu 재배선과 WPR 절연층 계면의 정량적 계면접착에너지 측정방법 비교 평가 (Comparison of Quantitative Interfacial Adhesion Energy Measurement Method between Copper RDL and WPR Dielectric Interface for FOWLP Applications)

  • 김가희;이진아;박세훈;강수민;김택수;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제25권2호
    • /
    • pp.41-48
    • /
    • 2018
  • Fan-out wafer level packaging (FOWLP) 적용을 위한 최적의 Cu 재배선 계면접착에너지 측정방법을 도출하기 위해, 전기도금 Cu 박막과 WPR 절연층 계면의 정량적 계면접착에너지를 $90^{\circ}$ 필 테스트, 4점 굽힘 시험법, double cantilever beam (DCB) 측정법을 통해 비교 평가 하였다. 측정 결과, 세 가지 측정법 모두 배선 및 패키징 공정 후 박리가 일어나지 않는 산업체 통용 기준인 $5J/m^2$보다 높게 측정되었다. 또한, DCB, 4점 굽힘 시험법, $90^{\circ}$ 필 테스트 순으로 계면접착에너지가 증가하는 거동을 보였는데, 이는 계면파괴역학 이론에 의해 위상각 증가에 따라 이종재료 계면균열 선단의 전단응력성분 증가에 따른 소성변형에너지 및 계면 거칠기 증가 효과에 의한 것으로 설명이 가능하다. FOWLP 재배선에 대한 최적의 계면접착에너지 도출을 위해서는 시편제작 공정, 위상각 차이, 정량적 측정 정확도 및 결합력 크기 등을 고려하여 4점 굽힘 시험법 또는 DCB 측정법을 적절히 혼용 사용하는 것이 타당한 것으로 판단된다.