• 제목/요약/키워드: Address Generator

검색결과 48건 처리시간 0.023초

Introduction of Generator Unit Controller and Its Tuning for Automatic Generation Control in Korean Energy Management System (K-EMS)

  • Park, Min-Su;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Automatic generation control (AGC) is an important function for load frequency control, which is being implemented in Energy Management System (EMS). A key feature of AGC is to back up governors to enhance the performance of frequency control. The governor regulates system frequency in several to ten seconds, while the droop control concept results in steady-state control error. AGC is a supplementary tool for compensation of the steady-state error caused by the droop setting of the governors. As the AGC target is delivered to each generator as an open loop control target, the generator output is not guaranteed to follow the AGC target. In this paper, we introduce generating unit controller (GUC) control block, which has the purpose of enabling the generator output to track the AGC target while maintaining the governor performance. We also address the tuning methods of GUC for better performance of AGC in the Korea Energy Management System (K-EMS).

고집적 메모리의 yield 개선을 위한 전기적 구제회로 (An Electrical Repair Circuit for Yield Increment of High Density Memory)

  • 김필중;김종빈
    • 한국전기전자재료학회논문지
    • /
    • 제13권4호
    • /
    • pp.273-279
    • /
    • 2000
  • Electrical repair method which has replaced laser repair method can replace defective cell by redundancy’s in the redundancy scheme of conventional high density memory. This electrical repair circuit consists of the antifuse program/read/latch circuits, a clock generator a negative voltage generator a power-up pulse circuit a special address mux and etc. The measured program voltage of made antifuses was 7.2~7.5V and the resistance of programmed antifuses was below 500 Ω. The period of clock generator was about 30 ns. The output voltage of a negative voltage generator was about 4.3 V and the current capacity was maximum 825 $mutextrm{A}$. An antifuse was programmed using by the electric potential difference between supply-voltage (3.3 V) and output voltage generator. The output pulse width of a power-up pulse circuit was 30 ns ~ 1$mutextrm{s}$ with the variation of power-up time. The programmed antifuse resistance required below 44 ㏀ from the simulation of antifuse program/read/latch circuit. Therefore the electrical repair circuit behaved safely and the yield of high densitymemory will be increased by using the circuit.

  • PDF

Simulation for Shop Floor Control

  • Cho, Hyunbo
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 1996년도 춘계학술대회
    • /
    • pp.15-15
    • /
    • 1996
  • A shop floor control system (SFCS) is the central part of a CIM system used to control the activities of several pieces of manufacturing equipment (e.g., NC machines, robots, conveyors, AGVs, AS/RS). The SFCS receives orders and related process plans, and then performs selecting a specific process routing, allocating resources, scheduling the workpieces, downloading the processing instructions (e.g., RS-274 instructions for NC machines, VAL II programs for robot), monitoring the progress of activities, detecting and recovering from errors, and preparing reports on the status of the manufacturing system. Simulation has been utilized in discovering control policies used for resolving shop floor be control problems such as resource contentions, part dispatching, deadlock. The simulation model must be designed to respond to real-time data coming from a shop floor. However, to rapidly build a realtime simulation model of SFCS cannot be easily accomplished. This talk is to address an automatic program generator of discrete event simulation model for shop floor control from process plans and resource models. The program generator is capable of constructing complete discrete simulation models for multi-product and multi-stage flexible manufacturing systems.

  • PDF

고정지지를 갖는 11.4 MW급 선박용 발전기의 진동 특성 (Vibration Characteristics for 11.4 MW Class Marine Generator using Rigid Support)

  • 버광 다오;로날드 디 바로;김효정;이돈출
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.585-588
    • /
    • 2013
  • Electric motor with reduction gear systems are being adopted recently as main propulsion on the special-purposed ships. These specialized ships or offshore vessels require higher power rating generators for propulsion and accommodation power supply. This study investigated the cause of exciter components failure in the view of excessive vibration, force or abnormal ship motion in service. Countermeasures are proposed to address the exciter component failure. A 1.4 MW class dual-fuel engine generator using rigid foundation for a LNG carrier was used as research model.

  • PDF

전력시장의 발전기 보수계획을 고려한 확률적 발전 모델링 (Probabilistic Generation Modeling in Electricity Markets Considering Generator Maintenance Outage)

  • 김진호;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.418-428
    • /
    • 2005
  • In this paper, a new probabilistic generation modeling method which can address the characteristics of changed electricity industry is proposed. The major contribution of this paper can be captured in the development of a probabilistic generation modeling considering generator maintenance outage and in the classification of market demand into multiple demand clusters for the applications to electricity markets. Conventional forced outage rates of generators are conceptually combined with maintenance outage of generators and, consequently, effective outage rates of generators are newly defined in order to properly address the probabilistic characteristic of generation in electricity markets. Then, original market demands are classified into several distinct demand clusters, which are defined by the effective outage rates of generators and by the inherent characteristic of the original demand. We have found that generators have different effective outage rates values at each classified demand cluster, depending on the market situation. From this, therefore, it can be seen that electricity markets can also be classified into several groups which show similar patterns and that the fundamental characteristics of power systems can be more efficiently analyzed in electricity markets perspectives, for this classification can be widely applicable to other technical problems in power systems such as generation scheduling, power flow analysis, price forecasts, and so on.

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

Development of Frequency Discriminated Simulative Target Generator Based on DRFM for Radar System Performance Evaluation

  • Chung, Myung-Soo;Kim, Woo-Sung;Bae, Chang-Ok;Kang, Seung-Min;Park, Dong-Chul
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.213-219
    • /
    • 2011
  • Simulative target generators are needed for testing and calibrating various radar systems. The generator in this study discriminates the transmitting frequency from a radar and simulates parameters like target range, range rate, and atmospheric attenuation using the digital RF memory technique. The simulative target echo is then sent to the radar for testing and evaluation. This paper proposes a novel architecture for controlling the digital RF memory so it continually writes ADC data to the memory and reads it for the DAC with increasing one step address in order to control the delay of target range in a simple way. The target echo is programmed according to various preprogrammed scenarios and is generated in real time using a wireless local area network (LAN). To analyze the detected and generated target information easily, the system times for the radar and simulative target generator are synchronized using a global positioning system (GPS).

반얀망 ATM 스위치에서 충돌 제거를 위한 비충돌 패턴 발생기 설계 (Design of the non-blocking pattern generator for the elimination of conflicts in banyan ATM switch)

  • 이주영;정재일
    • 전자공학회논문지S
    • /
    • 제35S권12호
    • /
    • pp.8-16
    • /
    • 1998
  • 본 논문에서는 반얀망 ATM 스위치를 위한 비충돌 패턴 발생기를 제안하고, 그 성능을 시뮬레이션에 의해 평가한다. 제안하는 비충돌 패턴 발생기는 우선 입력 셀 들을 입력, 출력 주소쌍을 이용하여, 두 개의 그룹, 즉, 충돌 유발 셀 그룹과 비충돌 셀 그룹 으로 분리한다. 분류된 충돌 유발 셀 들은 충돌 테이블을 이용하여 새로운 비충돌 입력 주소를 재할당 받는다. 시뮬레이션 결과는 NBPG가 최소한의 변환만으로 비충돌 주소 패턴을 발생함을 보여준다.

  • PDF

Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구 (A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay)

  • 김광현;박지경;김준혁;김두웅;강성범;김철환;유영식;양정재;고윤태
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

다층형 블레이드를 적용한 소형 풍력발전기의 출력특성 (Output Characteristics of Small Wind Power Generator Applying Multi-Layered Blade)

  • 이민구;박왈서
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.663-667
    • /
    • 2017
  • 최근 화석연료의 사용으로 인한 연료고갈 및 환경문제가 대두되고 있으며 이를 해결하기 위한 대체에너지 개발이 시급한 실정이다. 풍력에너지는 대체에너지 중 지속적으로 무제한 사용할 수 있고 공해물질 배출이 없는 청정에너지로 각광받고 있다. 풍력발전은 바람에너지가 로터 블레이드를 통해서 운동에너지로 변환되고 다시 발전기를 통해서 전기에너지를 발생시키는 에너지 변환기술이며, 풍력발전기의 중요부품인 블레이드의 설계 및 제작은 매우 중요한 요소이지만, 우리나라는 이에 대한 기초자료 및 핵심기술 등이 부족하여 아직도 중요부품들을 외국에서 수입하여 사용하고 있는 실정이다. 본 연구에서는 저 풍속에서도 발전 가능한 다층형 구조의 블레이드를 소형풍력발전기에 적용하여 풍속 및 블레이드 개수에 따른 발전기의 출력특성을 분석하였다. 연구결과, 최대풍속 8m/s일 때 블레이드 3개를 적용하면 블레이드를 1개 및 2개를 적용했을 때보다 발전기 출력전압은 33% 및 18%로 증가되었고, 발전기 출력전류는 33% 및 15%로 증가되었으며 발전기 RPM은 23% 및 13%로 증가되었다. 본 연구에서다층형 구조의 블레이드를 소형풍력발전기에 적용한 결과 발전기의 출력특성이 향상되었고 저 풍속에서도 전기에너지의 수집이 가능함을 확인하였다.