• Title/Summary/Keyword: Addition Test

Search Result 12,040, Processing Time 0.038 seconds

Comparison Analysis of Fiber Distribution and Workability for Amorphous Steel Fiber Reinforced Concrete (비정질강섬유 보강콘크리트 작업성 및 섬유 분산성 비교분석)

  • Kim, Byoung-Il;Lee, Sea-Hyun
    • Resources Recycling
    • /
    • v.23 no.4
    • /
    • pp.47-57
    • /
    • 2014
  • The research was conducted to analyze workability and fiber distributions of amorphous steel fiber reinforced concrete by changing fiber length and fiber addition ratio. The inverted slump cone and vebe tests as well as slump test was performed to understand the fluidity of amorphous steel fibers which have quite different appearance compared to conventional steel fibers. Test results showed that thin plate type of amorphous steel fibers required different test approach to figure out workability since the reduction of workability from slump test was different that from inverted slump cone and vebe tests. In conclusion, fluidity of amorphous steel fibers to concrete was significantly degraded as fiber length and addition ratio increase. Also, fibers space in cement matrix was apparently reduced as the increase of fiber length and addition ratios without fiber balling.

Goodness-of-fit Test for Rayleigh Distribution

  • Sultan, K.S.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.1
    • /
    • pp.41-51
    • /
    • 2007
  • In this paper, we use the moments of order statistics derived by Lieblein (1955) to develop the correlation goodness-of-fit test for the Rayleigh distribution. In such we simulate the percentage points of the test statistics for the one-parameter and two-parameter cases. In addition, we calculate the power of the proposed tests based on some alterative distributions. Finally, we apply the procedures developed in the paper to some real data.

  • PDF

Load Test and Remote Monitoring of P.C. Box Girder Bridge (P.C. BOX 교량의 재하시험 및 원격계측 유지관리 시스템)

  • Lee, Sung-Woo;Doobyong Bae;Lee, Sun-Goo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.122-131
    • /
    • 1995
  • Load test for newly introduced precast segmental bridge is carried out to experimentally evaluate load carrying capacity, Analysis accompanied with the test is also performed and the results are used in the evaluation. In addition to initial evaluation of the bridge by load test, remote dynamic monitoring system to perform realtime assessment of the bridge condition is also under development. In this paper the procedure and results of load test and evaluation are presented along with introduction of dynamic monitoring system.

  • PDF

Possibility of Generalization of Principles for Multi-Digit Addition and Subtraction (세 자리 수의 범위에서 학습한 덧셈과 뺄셈 원리의 일반화 가능성)

  • Chang, Hyewon;Lim, Miin
    • School Mathematics
    • /
    • v.19 no.1
    • /
    • pp.137-151
    • /
    • 2017
  • This study aims to investigate the possibility of elementary students' generalization from three-digit numbers to multi-digit numbers in principles for addition and subtraction. One of main changes was the reduction of range of numbers for addition and subtraction from four-digit to three-digit. It was hypothesized that the students could generalize the principles of addition and subtraction after learning the three-digit addition and subtraction. To achieve the purpose of this study, we selected two groups as a sampling. One is called 'group 2015' who learned four-digit addition and subtraction and the other is called 'group 2016' who learned addition and subtraction only to three-digit. Because of the particularity of these subjects, this study covered two years 2015~2016. We applied our addition and subtraction test which contains ten three-digit or four-digit addition and subtraction items, respectively. We collected their results of the test and analyzed their differences using t-test. The results showed statistically meaningful difference between the mean score of the two groups only for four-digit subtraction. Based on the result, we discussed and made some didactical suggestions for teaching multi-digit addition and subtraction.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

A Study on Fatigue strength by hardenability of Boron Addition Steel (보론 첨가강의 경화기구에 따른 기계적 성질에 관한 연구)

  • Lee, Jong-Hyung;Yoo, Duck-Sang;Park, Shin-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.299-305
    • /
    • 2003
  • This research is for the relationship with heat treatment cooling temprature and the characteristic of Mechanical properties of Boron-Addition-Steel, the main material and SM25C steel, the sub material, structure viewing fractography, hardness test, tensite test and are carried out after the manufacturing small-specimen treated with heat of $750^{\circ}C$, $850^{\circ}C$, $1050^{\circ}C$. The influence to the Mechanical properties accompanied by AISI51B20, Boron-Addition-steel shows the following result. 1. The influenc of heat treatment by the content of cabon-steel is dominant. Addition of boron result is Strengthening structure effectively by segregation and improving over all mechanical characters such as good. it results from the increase of temacity by the stability of inter granular with improvement of harden-ability. 2. Boron-Addition-Steel exist in the from of martensite structure accompanied by the ferrite precipitition centering around grain boundary, and is improved to Hv 200. 3. The height of harden-ability and fatigue stress the influence of heat results from crystal structure of martensite by difference of strength level in the structure of ferrite and doesn't have am effect on sensibility of temperature, and turns out to defend on production and growth of Matrix-structure-factor.

  • PDF

Quality Bread as Influenced by Sweet Pumpkin Powder

  • Yoo, Jung-Sang;Seog, Eun-Ju;Lee, Jun-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.11 no.4
    • /
    • pp.339-343
    • /
    • 2006
  • Physicochemical properties of bread as influenced by the addition of sweet pumpkin powder (SPP) were investigated. Freeze-dried sweet pumpkin was ground, sieved through a laboratory sieve and a fraction with particles less than $250\;{\mu}m$ was used. Amount of SPP added to the bread was found to affect the bread quality significantly (p<0.05). Loaf volume and weight of the control were significantly higher than others (p<0.05) and decreased significantly (p<0.05) with the addition of SPP. In other words, the enrichment of product with SPP decreased bread volume and weight without significant changes in the moisture content. There were distinctive color changes with the addition of the powder: L- and a-values were reduced but b-value was significantly increased (p<0.05). The hardness, springiness, and gumminess of bread were found to increase with the addition of the powder. Consumer test indicated that bread contained with 3% SPP had the highest overall acceptability score while 1 or 5% addition produced an acceptable quality for the bread.

The Quality Characteristics of Sulgidduk with the Addition of Citron Preserved in Sugar (당절임 유자를 첨가한 설기떡의 품질특성)

  • Lee Jin-Sook;Hong Jin-Sook
    • Korean journal of food and cookery science
    • /
    • v.21 no.6 s.90
    • /
    • pp.851-858
    • /
    • 2005
  • This study investigated the most desirable mixture ratio of citron preserved in sugar to rice flour for Yuza Sulgidduk(Sulgidduk added with Citron). The moisture contents were $39\~40\%$ The L-value was decreased with increasing addition of Citron, while a- and b-values were increased. The pH was increased with addition of citron. In the mechanical evaluation, hardness was the highest at $\0%$ and the lowest at $26\%$ citron content during the storage period. Cohesiveness was decreased and adhesiveness was increased during the storage period. Springiness showed little difference among the different levels of citron addition. Gumminess decreased with increasing citron content. Brittleness was the highest at $0\%$ level and the lowest at $26\%$ level. In the sensory test characteristics, the color, flavor, sweetness, sourness, astringency were increased with addition of citron. The softness, moistness, chewiness and the overall-acceptability were the highest at $20\%$ level. Consequently, Yuza Sulgidduk with the addtion of $20\%$ citron to rice flour was determined to be the best recipe in terms of the sensory test results.

Corrosion characteristics in stress and various environments with Sn addition to Cu pipe (구리 배관의 Sn 첨가에 따른 응력 및 다양한 환경에서의 부식 특성)

  • Serim Kim;Uijun Kim;Myeonghoon Lee;Seunghyo Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.3
    • /
    • pp.192-200
    • /
    • 2024
  • Cu as a heat exchanger tube is an important component in thermal fluid transfer. However, Cu tubes are exposed to stress in certain environments, leading to stress corrosion cracking (SCC). In this study, the effect of Sn addition on microstructure and corrosion characteristics was examined. The microstructural examination revealed the presence of columnar crystal and a grain refinement due to the addition of Sn. Electrochemical measurements showed that the 5 wt.% NH3 environment was the most vulnerable environment to Cu corrosion, and the corrosion current density increased as stress increased. The immersion test exhibited the formation of Cu2O and Cu(OH)2 corrosion product in 3.5 wt.% NaCl and 5 wt.% NH3 environments, respectively. Results indicated that Sn addition to Cu was an important factor in improving the mechanical strength.

Verification Method to Detect the Fake Test Data in Military Supplies (군수업체 시험 데이터 및 시험 시스템 유효성 점검을 위한 제언)

  • Chung, Ilhan;Joo, Jinchun;Kim, Sunggon;Cho, Hyeonghwan;Ahn, Namsu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.231-240
    • /
    • 2016
  • Recently, fake test data of power cables in nuclear power plants was a terrible shock to the citizens. Some cable companies manipulated the test data to make unfair profits. In addition, fake test data cases were found in military supplies. The fake test data cases focused on parts of army's tank, armored car. This paper propose a new method that can detect fake test data using known statistical methods. In addition, the method was implemented in Microsoft Excel to allow easy use. Lastly, a check sheet was proposed to check the validity of the test system of military suppliers. By detecting and checking the fake test data, it is expected that our new method will play an important role in quality assurance of military supplies.