• 제목/요약/키워드: Active shielding

검색결과 39건 처리시간 0.044초

능동 차폐형 초전도 MRI 마그네트의 형상 최적화 (Shape Optimization of Active Shield Superconducting MRI Magnet)

  • 진홍범;오봉환;류강식;송준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.210-212
    • /
    • 1996
  • A nonlinear optimization method for the shape optimization of actively shielded superconducting MRI magnet is presented. The presented design method can optimize both main coil and shielding coil simultaneously by setting constraints on stray field intensity at a specified distance from the magnet center. A 1 Tesla actively shielded superconducting MRI magnet, with 30cm bore diameter, is designed using the presented method.

  • PDF

아크 용접에서 구동력에 따른 열 및 물질 유동에 관한 연구

  • 김원훈;나석주
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1996년도 제7회 학술강연회논문집
    • /
    • pp.27-41
    • /
    • 1996
  • In this study the heat transfer and fluid flow of the molten pool in stationary gas tungsten arc welding using argon shielding gas were investigated. Transporting phenomena from the welding arc to the base material surface, such as current density, heat flux, arc pressure and shear stress acting on the weld pool surface, were taken from the simulation results of the corresponding welding arc. Various driving forces for the weld pool convection were considered, self-induced electromagnetic, surface tension, buoyancy, and impinging plasma arc forces. Furthermore, the effect of surface depression due to the arc pressure acting on the molten pool surface was considered. Because fusion boundary has a curved and unknown shape during welding, a boundary-fitted coordinate system was adopted to precisely describe the boundary for the momentum equation. The numerical model was applied to AISI 304 stainless steel and compared with the experimental results.

  • PDF

자기공명영상촬영용 경사자계코일의 3차원설계 (3-Dimensional Design of Gradient Coils for Magnetic Resonance Imaging)

  • 류연철;현정호;이흥규;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.235-237
    • /
    • 2006
  • In this paper, the previous 2-D gradient coil design method using loop current elements is extended to 3-D or multi-layer structures which is useful for various MRI applications including MR microscopic imaging where relatively large space may be available for the implementation of the gradient coils. Either the power consumption or the stored energy (thus, inductance), or the combination of the two can be minimized with a set of chosen target field constraints. Complete 3-D design equations for the optimization as well as inductance or resistance calculation are derived. An effective coil shape correction method for a curved current pattern is also developed. The design method can also be easily extended to the active shielding structure.

  • PDF

철도소음 저감 향상을 위한 방음벽 상단의 능동제어장치 (Actively controlled sound field on the top edge of noise barriers for railway noise reduction)

  • 고효인;조준호;김재철;이찬우;한환수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.332-337
    • /
    • 2005
  • In this study the sound field on the surface of the top edge of noise barriers is actively minimized to enhance the shielding effect without increasing the hight of the barrier. First the results of a numerical study are shown; the sound field reduction in the far field due to a cylindrical active headpiece attached to a semi-infinite screen and the related control parameters are investigated. The results of a model experiment in an anechoic chamber and optimal control parameters for noise control on the railway side are shown and discussed.

  • PDF

자기적으로 결합된 초전도 마그네트의 퀜치보호에 대한 연구 (Study on the quench protective circuit for inductively coupled superconducting magnet systems)

  • 고락길;배준한;심기덕;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.41-43
    • /
    • 2001
  • We studied on effective quench protection method to prevent damage from unexpected quench of the inductively coupled superconducting magnet systems for magnetic resonance imaging. And we suggested quench protection circuit that is combined with several protection techniques. This circuit has the capacity to maintain the symmetric nature of the magnetic field and the active shielding effect and to protect shim coils during a quench.

  • PDF

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

Graphene field-effect transistor for radio-frequency applications : review

  • Moon, Jeong-Sun
    • Carbon letters
    • /
    • 제13권1호
    • /
    • pp.17-22
    • /
    • 2012
  • Currently, graphene is a topic of very active research in fields from science to potential applications. For various radio-frequency (RF) circuit applications including low-noise amplifiers, the unique ambipolar nature of graphene field-effect transistors can be utilized for high-performance frequency multipliers, mixers and high-speed radiometers. Potential integration of graphene on Silicon substrates with complementary metal-oxide-semiconductor compatibility would also benefit future RF systems. The future success of the RF circuit applications depends on vertical and lateral scaling of graphene metal-oxide-semiconductor field-effect transistors to minimize parasitics and improve gate modulation efficiency in the channel. In this paper, we highlight recent progress in graphene materials, devices, and circuits for RF applications. For passive RF applications, we show its transparent electromagnetic shielding in Ku-band and transparent antenna, where its success depends on quality of materials. We also attempt to discuss future applications and challenges of graphene.

저성능 자기차폐실에서 64채널 DROS 2차 미분계 시스템의 잡음 특성 (Noise Characteristics of 64-channel 2nd-order DROS Gradiometer System inside a Poorly Magnetically-shielded Room)

  • 김진목;이용호;유권규;김기웅;권혁찬;박용기
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.33-39
    • /
    • 2006
  • We have developed a second-order double relaxation oscillation SQUID(DROS) gradiometer with a baseline of 35 mm, and constructed a poorly magnetically-shielded room(MSR) with an aluminum layer and permalloy layers for magnetocardiography(MCG). The 2nd-order DROS gradiometer has a noise level of 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz inside the heavily-shielded MSR with a shielding factor of $10^3$ at 1 Hz and $10^4-10^5$ at 100 Hz. The poorly-shielded MSR, built of a 12-mm-thick aluminum layer and 4-6 permalloy layers of 0.35 mm thickness, is 2.4mx2.4mx2.4m in size, and has a shielding factor of 40 at 1 Hz, $10^4$ at 100 Hz. Our 64-channel second-order gradiometer MCG system consists of 64 2nd-order DROS gradiometers, flux-locked loop electronics, and analog signal processors. With the 2nd-order DROS gradiometers and flux-locked loop electronics installed inside the poorly-shielded MSR, and with the analog signal processor installed outside it, the noise level was measured to be 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz on the average even though the MSR door is open. This result leads to a low noise level, low enough to obtain a human MCG at the same level as that measured in the heavily-shielded MSR. However, filters or active shielding is needed fur clear MCG when there is large low-frequency noise from heavy air conditioning or large ac power consumption near the poorly-shielded MSR.

  • PDF

기판집적 도파관(SIW)을 기반으로 하는 고효율 능동 위상 배열안테나 (High Efficiency Active Phased Array Antenna Based on Substrate Integrated Waveguide)

  • 이해영
    • 한국전자파학회논문지
    • /
    • 제26권3호
    • /
    • pp.227-247
    • /
    • 2015
  • 저손실, 전자기 완전차폐, 고전력 특성을 갖는 기판집적 도파관(SIW)을 이용하여 X-band $8{\times}16$ 이중편파 능동 위상배열안테나 시스템을 구현하였다. 16-way SIW 전력분배 네트워크의 측정된 순수 삽입손실(0.65 dB)은 마이크로스트립 경우보다 1 dB 감소하였으며, SIW 부배열($1{\times}16$) 안테나 소자의 측정된 방사효율(73 %)은 약 2배(3 dB) 향상되었다. 이러한 SIW를 이용한 분배손실과 방사효율의 상당한 개선은 능동 위상 배열안테나 시스템에서 고전력 증폭기의 최대출력(P1 dB)을 저감하고, 총 전력소모를 약 30 % 절감할 것이다. SIW 기반으로 제작된 X-band $8{\times}16$ 이중편파 능동 위상 배열안테나 시스템을 이론적인 제어벡터만을 생성하여 0도, 5도, 9도, 18도의 정밀한(최대편차 2도) 빔 조향을 측정하였으며, 열주기/진공 시험에서 우주환경 적합성을 확인하였다. 고효율 SIW 배열안테나 시스템은 고성능 레이더는 물론 차세대 무선통신(5G)을 위한 Massive MIMO와 다양한 밀리미터파 통신시스템(60 GHz WPAN, 77 GHz 자동차 레이더, 초고속 디지털 전송시스템 등)에 매우 유용할 것으로 기대한다.

MRI용 차폐된 X,Y-경사자계코일의 최소전력설계 (Minimum-Power Design of Actively-Shielded Transverse Gradient Coils for MRI)

  • 이덕래;김선경;양윤정;이흥규;안창범;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.307-309
    • /
    • 1996
  • A new design scheme of actively-shielded x,y-gradient coils for Magnetic Resonance Imaging(MRI) is proposed. An actively-shielded x-gradient coil has been designed as an example and the results are presented. In MRI, gradient coils are needed for spatial selection and position coding to obtain the position information of the NMR signal. They are usually switched on and off during imaging and the eddy current induced by the current switching usually degrades the final image quality To reduce or remove this kind of problems, the active shielding has been proposed few years ago. In this paper, a new design scheme for actively-shielded x,y-gradient coils, namely, a minimum-power design scheme using current-loop elements, has been proposed. Its utility in designing MRI gradient coils has been shown by using simulation. The design scheme seems to be useful for actively-shielded transverse gradient coils, even of non-cylindrical or of arbitrary-selected shapes.

  • PDF