• Title/Summary/Keyword: Active Integrator

Search Result 51, Processing Time 0.038 seconds

A Basic Study on the Measurement Induced Voltages due to Lightning Discharges (뇌방전에 의한 유도전압의 측정에 대한 기초적 연구)

  • Lee, Bok-Hee;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Woo-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.559-564
    • /
    • 2004
  • This paper deals with the device for measuring the time-varying magnetic fields and induced voltages caused by lightning discharges. The two magnetic field measuring systems were designed and made. One consists of the loop-type magnetic field sensor with the active integrator operated by a differential amplifier. The other consists of the loop-type magnetic field sensor and Labview software. The loop-type magnetic field sensor detects the time derivative of the magnetic field being measured, and the signal detected is integrated by the Labview software. As a consequence, from the calibration experiments, the frequency bandwidth of the full measuring system ranges from 400 [Hz] to 1 (MHz) and the response sensitivity are 0.98 (mV/nT) and 22 (mV/nT) for the magnetic field sensor of 2 turns and 6 turns, respectively. Also, the results obtained by the two measuring devices well agreed with each other.

  • PDF

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF

Application of LQR for Phase-Locked Loop Control Systems

  • Khumma, Somyos;Benjanarasuth, Taworn;Isarakorn, Don;Ngamwiwit, Jongkol;Wanchana, Somsak;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.520-523
    • /
    • 2004
  • A phase-locked loop control system designed by using the linear quadratic regulator approach is presented in this paper. The system thus designed is optimal system when system is in locked state and the parameter value of loop filter which is an active PI filter can be obtained easily. By considering the structure of loop filter of phase-locked loop is included in the process to be controlled, a type 1 servo system can be constructed when voltage control oscillator is considered as an integrator. The integral gain of the proposed system obtained by linear quadratic regulator approach can be used as an optimal value to design the parameter of loop filter. The implemented result in controlling the second-order lag pressure process by using the proposed scheme show that the system response is fast with no overshoot and no steady-state error. Furthermore, the experimental results are also shown in term of output disturbance effect rejection, tracking and process parameter changed.

  • PDF

Synthesis of Active Filters Using Operational Amplitiers of Finite GB Product (GB 적을 고려한 능동려파회로구성에 관한 연구)

  • Lee, Tae-Won;Jo, Yong-Hyeon;Ryu, Je-Geun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.4
    • /
    • pp.45-52
    • /
    • 1980
  • In order to eliminate the phase errors caused by the finite GB product of operational amplifiers, novel integnator circuits are proposed. These circuits are characterized by their positive phase error angles and integrator selectivity. The positive sign of the Q and of the circuits compensates the negative selectivity and phase error angles, inherent in the integrated operational amplifiers. Miller inverting intergrator of a biquad circuit realized by Thomas is replaced by the proposed circuit and the band-pass frequency response of the modified biquad network is experimentally analyzed. A considerable improvement is recognized to such extent that the center frequency of the band-pass filter is allowed to be shifted up to 20KHz, which has been infeasible with conventional biquad networks.

  • PDF

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (電動力設備의 運轉에 의해 發生되는 磁界의 測定과 解析)

  • Lee, Bok Hui
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.146-146
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]∼0.234[mV/μT]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

PLL Control Strategy for ZVRT(Zero Voltage Ride Through) of a Grid-connected Single-phase Inverter (계통연계형 단상 인버터의 ZVRT(Zero Voltage Ride Through)를 위한 PLL 제어 전략)

  • Lee, Tae-Il;Lee, Kyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.169-180
    • /
    • 2019
  • Grid codes for grid-connected inverters are essential considerations for bulk grid systems. In particular, a low-voltage ride-through (LVRT) function, which can contribute to the grid system's stabilization with the occurrence of voltage sag, is required by such inverters. However, when the grid voltage is under zero-voltage condition due to a grid accident, a zero-voltage ride-through (ZVRT) function is required. Grid-connected inverters typically have phase-locked loop (PLL) control to synchronize the phase of the grid voltage with that of the inverter output. In this study, the LVRT regulations of Germany, the United States, and Japan are analyzed. Then, three major PLL methods of grid-connected single-phase inverters, namely, notch filter-PLL, dq-PLL using an active power filter, and second-order generalized integrator-PLL, are reviewed. The proposed PLL method, which controls inverter output under ZVRT condition, is suggested. The proposed PLL operates better than the three major PLL methods under ZVRT condition in the simulation and experimental tests.

Magnetic Field Measuring System by using Loop-type Sensor (루우프형 센서를 이용한 자장측정계)

  • Lee, Bok-Hee;Kil, Gyung-Suk;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.14-21
    • /
    • 1995
  • This paper deals with the active magnetic field measuring system which can measure the time-varying magnetic fields generated by power installations and lightning discharges. The magnetic field measuring system consists of the loop-type magnetic field sensor and the active integrator operated by a differential amplifier. The theoretical principle and design rule of the time-varying magnetic field measuring device and the calibration apparatus are introduced. From the calibration experiments, the frequency bandwidth of the full measuring system ranges from 270 Hz to about 2.3 MHz and the response sensitivity for magentic field strength is 128 $mV/{\mu}T$, respectively, and the calculated B-field values in the center of the loop-type sensor versus the the applied current made with a region of ${\pm}3\;%$error. The actual survey experiments by using lightning impulse current and oscillating impulse current were performed, the results of comparision between the input current waveforms and the magnetic field waveforms are a good agreement with each others and their deviations are less than 0.5 %.

  • PDF

Design of Low Power Sigma-delta ADC for USN/RFID Reader (USN/RFID Reader용 저전력 시그마 델타 ADC 변환기 설계에 관한 연구)

  • Kang, Ey-Goo;Hyun, Deuk-Chang;Hong, Seung-Woo;Lee, Jong-Seok;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.800-807
    • /
    • 2006
  • To enhance the conversion speed more fast, we separate the determination process of MSB and LSB with the two independent ADC circuits of the Incremental Sigma Delta ADC. After the 1st Incremental Sigma Delta ADC conversion finished, the 2nd Incremental Sigma Delta ADC conversion start while the 1st Incremental Sigma Delta ADC work on the next input. By determining the MSB and the LSB independently, the ADC conversion speed is improved by two times better than the conventional Extended Counting Incremental Sigma Delta ADC. In processing the 2nd Incremental Sigma Delta ADC, the inverting sample/hold circuit inverts the input the 2nd Incremental Sigma Delta ADC, which is the output of switched capacitor integrator within the 1st Incremental Sigma Delta ADC block. The increased active area is relatively small by the added analog circuit, because the digital circuit area is more large than analog. In this paper, a 14 bit Extended Counting Incremental Sigma-Delta ADC is implemented in $0.25{\mu}m$ CMOS process with a single 2.5 V supply voltage. The conversion speed is about 150 Ksamples/sec at a clock rate of 25 MHz. The 1 MSB is 0.02 V. The active area is $0.50\;x\;0.35mm^{2}$. The averaged power consumption is 1.7 mW.

Design of digital decimation filter for sigma-delta A/D converters (시그마-델타 A/D 컨버터용 디지털 데시메이션 필터 설계)

  • Byun, San-Ho;Ryu, Seong-Young;Choi, Young-Kil;Roh, Hyung-Dong;Nam, Hyun-Seok;Roh, Jeong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.2
    • /
    • pp.34-45
    • /
    • 2007
  • Digital decimation filter is inevitable in oversampled sigma-delta A/D converters for the sake of reducing the oversampled rate to Nyquist rate. This paper presented a Verilog-HDL design and implementation of an area-efficient digital decimation filter that provides time-to-market advantage for sigma-delta analog-to-digital converters. The digital decimation filter consists of CIC(cascaded integrator-comb) filter and two cascaded half-band FIR filters. A CSD(canonical signed digit) representation of filter coefficients is used to minimize area and reduce in hardware complexity of multiplication arithmetic. Coefficient multiplications are implemented by using shifters and adders. This three-stage decimation filter is fabricated in $0.25-{\mu}m$ CMOS technology and incorporates $1.36mm^2$ of active area, shows 4.4 mW power consumption at clock rate of 2.8224 MHz. Measured results show that this digital decimation filter is suitable for digital audio decimation filters.

Development of High Stable Instrumentation and Analytic Techniques for Radioactive Pulses (방사선 펄스의 고안정 계측 및 분석기술 개발)

  • 길경석;송재용;한주섭;김일권;손원진
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.303-308
    • /
    • 2001
  • An objection of this study is to develop a high stable measuring circuits and a analytic system for radioactive pulses. The proposed system consists of a pulse detection units for neutrons and gamma-rays a programmable high voltage supply unit and a digital signal processor. The programmable high voltage supply unit designed can generate DC voltage up to 1,500 V at 5 V input and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHzAlso, pulse height distribution in accordance with pulse counts is important data in analyzing radioactive pulses. In this study, A/D convertor (12bit, 100ms) and DSP (TMS320C31-60) are used to analyze the pulse height, and the analytic system is designed to be operated in PC-base.

  • PDF