• Title/Summary/Keyword: Acquisition Type

Search Result 542, Processing Time 0.023 seconds

A Study on the Optimum Design of Charge Pump PLL for High Speed and Fast Acquisition (고속동작과 빠른 Acquisition 특성을 가지는 Charge Pump PLL의 최적설계에 관한 연구)

  • Woo, Young-Shin;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.718-720
    • /
    • 1999
  • This paper describes a charge pump PLL architecture which achieves high frequency operation and fast acquisition. This architecture employs multi-phase frequency detector comprised of precharge type phase frequency detector and conventional phase frequency detector. Operation frequency is increased by using precharge type phase frequency detector when the phase difference is small and acquisition time is shortened by using conventional phase frequency detector and increased charge pump current when the phase difference is large. By virtue of this multi-phase frequency detector structure, the maximum operating frequency of 694MHz at 3.0V and faster acquisition were achieved by simulation.

  • PDF

The Study on the Analysis of the Rate of Information Acquisition and the Observation Time shown at the Observation of Interior Space (실내공간의 주시에 나타난 정보획득률과 주시시간 분석에 관한 연구)

  • Choi, Joo-Young;Kim, Joo-Hyun;Choi, Gae-Young;Lee, Jeong-Ho;Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.183-191
    • /
    • 2011
  • This study is to set up the appropriate range of observation time through contemplating the characteristics of observation time run for the information acquisition of space. The conclusions reached through this study are as the followings. First, this study could find out that even though the evaluation elements on the three types for image evaluation were the same, the information acquisitions were different as those types varied. On the other hand, the change of the average run-time by type for the information acquisition was found not to be big, in other words, even though the run-time was alike, the information acquisitions varied depending on the type. Second, he evaluation by language media showed the average value by element had the order of [shape>position>number>existence] and the range of their run-time was 94.6~102.9 seconds. The average rate of information acquisition shown at the visual media had the order of [composition>shape>material&color] and the range of run-time was 93.1~99.7 seconds. Third, the evaluation by language media showed that for male subjects the range of information acquisition rate was 39.1~91.4% and that of run-time 85.1~106.0 seconds and for female ones 46.0~94.6% and 96.3~112.3 seconds respectively. In case of the visual media, male subjects showed the range of information acquisition rate was 40.3-66.7% and the range of run-time 82.4~97.9 seconds and the female ones, 42.2~71.0% and 94.0~115.1 seconds respectively, through which we could see that at the evaluation by language media and visual media both the female's range of information acquisition and that of observation time were higher than the male's.

DATA ACQUISITION SYSTEM OF THE SOFT

  • Moon, Yong-Jae;Park, Young-Deuk;Jang, Be-Ho;Sim, Kyung-Jin;Yun, Hong-Sik;Kim, Jung-Hoon
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.243-250
    • /
    • 1996
  • Data acquisition system mounted on the Solar Flare Telescope at Bohyunsan Optical Astronomy Observatory is briefly described. The system is made up with CCD cameras, an image processor, a PCI-type PC and a SUN workstation. The image processor, MVC 150/40 comprises a variable scan acquisition module, an image manager and a binary correlator computational module. A typical polarization image of a sunspot is presented to demonstrate performance of the system.

  • PDF

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

Acquisition Methods for Disaster Archives Based on the Issue Life Cycle Model (이슈 생존 주기 모형 기반 재난 아카이브 수집 방안)

  • Yoo, Ho-Suon;Oh, Hyo-Jung
    • Journal of the Korean Society for information Management
    • /
    • v.35 no.2
    • /
    • pp.115-139
    • /
    • 2018
  • Due to the value and the importance of preservation of disaster web records, to build disaster archives is globally becoming a national challenge. This study proposes a acquisition methods based on the issue life cycle model for collecting disaster web records. We firstly analyzed web records acquisition status, methods and period of domestic and foreign disaster archives. In addition, the issue life cycle model was derived by collecting and analyzing the disaster issues in the last 10 years. As the results of the analysis, the issue life cycle model was divided into the sudden type and periodic type according to the characteristics of the disaster. In conclusion, this study propose a method to collect web records according to each model and verify its applicability.

Continuance Usage of Smartwatch : Differences by Acquisition Type (스마트워치의 지속사용에 관한 연구 : 획득유형에 따른 차이 분석)

  • Yoo, Hye In;Lee, Choong C.;Yun, Haejung
    • Journal of Information Technology Services
    • /
    • v.19 no.2
    • /
    • pp.69-82
    • /
    • 2020
  • In the growth of IT industry, interest in wearable device has been globally rising along with the evolution of technology. A Smartwatch is expected to be at the center of wearable device industry in the future. However, there are some concerns that most of its actual sales are caused by gifts or bundling. Motivated by these issues, this study propounds the ideas that to enter the mainstream market, the empirical research is required for actual consumers who continue to use a smartwatch. The purpose of this study is to identify key factors affecting user satisfaction and antecedents affecting continuance intention to use from consumer perspectives. Further, assuming consumers' perceptions will be different according to how they acquired smartwatch, this study classified the group as direct buyers and acquired users. To achieve the purpose of the research, this study analyzes the usage of smartwatch by integrating the IS Success Model and IS Continuance and Habit Theory. We implemented the survey of 338 smartwatch users, and the research findings indicate that information quality and system quality have significant effects on satisfaction, and consequently satisfaction and habit positively affect the continuance intention to use. Additionally, it is found that there was a significant difference in the relationship between satisfaction and habit in the group divided by acquisition type. Based on these findings, this study provides theoretical and practical implications.

A Satellite Navigation Signal Scheme Using Zadoff-Chu Sequence for Reducing the Signal Acquisition Space

  • Park, Dae-Soon;Kim, Jeong-Been;Lee, Je-Won;Kim, Kap-Jin;Song, Kiwon;Ahn, Jae Min
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A signal system for improving the code acquisition complexity of Global Navigation Satellite System (GNSS) receiver is proposed and the receiving correlator scheme is presented accordingly. The proposed signal system is a hierarchical code type with a duplexing configuration which consists of the Zadoff-Chu (ZC) code having a good auto-correlation characteristic and the Pseudo Random Noise (PRN) code for distinguishing satellites. The receiving correlator has the scheme that consists of the primary correlator for the ZC code and the secondary correlator which uses the PRN code for the primary correlation results. The simulation results of code acquisition using the receiving correlator of the proposed signal system show that the proposed signal scheme improves the complexity of GNSS receiver and has the code acquisition performance comparable to the existing GNSS signal system using Coarse/Acquisition (C/A) code.

A Dynamic Camera Actuation System for Simultaneous in Situ Image Acquisition on a Lab-on-a-disk (랩-온-어-디스크를 위한 실시간 영상 조절 및 이미지 획득 시스템)

  • La, Moonwoo;Park, Sang Min;Park, Sung Jea;Kim, Dong Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1211-1216
    • /
    • 2013
  • In this study, a dynamic camera actuation system for simultaneous in situ image acquisition is developed to achieve real-time observation of transient liquid flow on a lab-on-a-disk. A disk-type electric circuit, namely circuit-on-a-disk, co-rotated with the lab-on-a-disk improves the dynamic image acquisition ability in terms of a frame rate. The circuit-on-a-disk is comprised of a camera connected with a motor, a microprocessor and a wireless communication module. The camera connected with the motor enables to realize dynamic tracking of a transient flow and real-time image acquisition. The obtained images can be simultaneously transferred by a video/audio transmitter unit to a personal computer. Also, the microprocessor receives signals from the personal computer, and then controls the focusing position of the camera. We are expecting that heaters, sensors, and light sources also can be integrated on the circuit-on-a-disk, and they will enable various functional actuations as well as precise image acquisition.

Design and Implementation of Seismic Data Acquisition System using MEMS Accelerometer (MEMS형 가속도 센서를 이용한 지진 데이터 취득 시스템의 설계 및 구현)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • In this paper, we design a seismic data acquisition system(SDAS) and implement it. This system is essential for development of a noble local earthquake disaster preventing system in population center. In the system, we choose a proper MEMS-type triaxial accelerometer as a sensor, and FPGA and ARM processor are used for implementing the system. In the SDAS, each module is realized by Verilog HDL and C Language. We carry out the ModelSim simulation to verify the performances of important modules. The simulation results show that the FPGA-based data acquisition module can guarantee an accurate time-synchronization for the measured data from each axis sensor. Moreover, the FPGA-ARM based embedded technology in system hardware design can reduce the system cost by the integration of data logger, communication sever, and facility control system. To evaluate the data acquisition performance of the SDAS, we perform experiments for real seismic signals with the exciter. Performances comparison between the acquired data of the SDAS and the reference sensor shows that the data acquisition performance of the SDAS is valid.

A BOC Signal Acquisition Scheme Based on Recombination of Sub-correlation Functions with Cyclostationarity (Cyclostationarity를 갖는 부 상관함수들의 재조합에 기반을 둔 BOC 신호 획득 기법)

  • Lee, Young-Po;Baek, Jee-Hyeon;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.7C
    • /
    • pp.459-466
    • /
    • 2011
  • This paper addresses the problem in the acquisition of binary offset carrier (BOC) signals employed in global navigation satellite systems, which is caused by the multiple side-peaks of the BOC autocorrelation function. We first observe that the side-peaks arise due to the fact that the BOC autocorrelation is made up of the sum of the sub-correlations shaped irregularly, and then, propose a novel acquisition scheme based on a recombination of the sub-correlations with cyclostationarity. The proposed scheme is demonstrated to remove the side-peaks completely for any type of BOC signal and to provide a performance improvement over the conventional schemes in terms of the mean acquisition time.