Browse > Article
http://dx.doi.org/10.7736/KSPE.2013.30.11.1211

A Dynamic Camera Actuation System for Simultaneous in Situ Image Acquisition on a Lab-on-a-disk  

La, Moonwoo (Department of Mechanical Engineering, POSTECH)
Park, Sang Min (Department of Mechanical Engineering, POSTECH)
Park, Sung Jea (Department of Mechanical Engineering, POSTECH)
Kim, Dong Sung (Department of Mechanical Engineering, POSTECH)
Publication Information
Abstract
In this study, a dynamic camera actuation system for simultaneous in situ image acquisition is developed to achieve real-time observation of transient liquid flow on a lab-on-a-disk. A disk-type electric circuit, namely circuit-on-a-disk, co-rotated with the lab-on-a-disk improves the dynamic image acquisition ability in terms of a frame rate. The circuit-on-a-disk is comprised of a camera connected with a motor, a microprocessor and a wireless communication module. The camera connected with the motor enables to realize dynamic tracking of a transient flow and real-time image acquisition. The obtained images can be simultaneously transferred by a video/audio transmitter unit to a personal computer. Also, the microprocessor receives signals from the personal computer, and then controls the focusing position of the camera. We are expecting that heaters, sensors, and light sources also can be integrated on the circuit-on-a-disk, and they will enable various functional actuations as well as precise image acquisition.
Keywords
Circuit-on-a-disk; Lab-on-a-disk; Real-time visualization; Image acquisition;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., and Kim, N., "Lab on a CD," Annu Rev Biomed Eng, Vol. 8, No. pp. 601-628, 2006.   DOI   ScienceOn
2 Ducree, J., Haeberle, S., Lutz, S., Pausch, S., Stetten, F. v., and Zengerle, R., "The Centrifugal Microfluidic Bio-disk Platform," J Micromech Microeng, Vol. 17, No. 7, pp. S103-S115, 2007.   DOI   ScienceOn
3 Schembri, C. T., Burd, T. L., Kopfsill, A. R., Shea, L. R., and Braynin, B., "Centrifugation and Capillarity Integrated into a Multiple Analyte Whole-Blood Analyzer," Journal of Automatic Chemistry, Vol. 17, No.3, pp. 99-104, 1995.   DOI
4 Lee, B. S., Lee, Y. U., Kim, H. S., Kim, T. H., Park, J., Lee, J. G., and et al., "Fully Integrated Lab-on-a-disc for Simultaneous Analysis of Biochemistry and Immunoassay from Whole Blood," Lab Chip, Vol. 11, No. 1, pp. 70-78, 2011.   DOI   ScienceOn
5 Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., and Kellogg, G. J., "Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays," Anal Chem, Vol. 71, No. 20, pp. 4669-4678, 1999.   DOI   ScienceOn
6 Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S. T., and Madou, M. J., "Design of a Compact Disk-like Microfluidic Platform for Enzyme-linked Immunosorbent Assay," Anal Chem, Vol. 76, No. 7, pp. 1832-1837, 2004.   DOI   ScienceOn
7 Jia, G. Y., Ma, K. S., Kim, J., Zoval, J. V., Peytavi, R., Bergeron, M. G., and et al., "Dynamic Automated DNA Hybridization on a CD (compact disc) Fluidic Platform," Sensor Actuat B-Chem, Vol. 114, No. 1, pp. 173-181, 2006.   DOI   ScienceOn
8 Cho, Y. K., Lee, J. G., Park, J. M., Lee, B. S., Lee, Y., and Ko, C., "One-step Pathogen Specific DNA Extraction from Whole Blood on a Centrifugal Microfluidic Device," Lab Chip, Vol. 7, No. 5, pp. 565-573, 2007.   DOI   ScienceOn
9 Puckett, L. G., Dikici, E., Lai, S., Madou, M., Bachas, L. G., and Daunert, S., "Investigation into the Applicability of the Centrifugal Microfluidics Platform for the Development of Protein-ligand Binding Assays Incorporating Enhanced Green Fluorescent Protein as a Fluorescent Reporter," Anal Chem, Vol. 76, No. 24, pp. 7263-7268, 2004.   DOI   ScienceOn
10 Honda, N., Lindberg, U., Andersson, P., Hoffmann, S., and Takei, H., "Simultaneous Multiple Immunoassays in a Compact Disc-shaped Microfluidic Device Based on Centrifugal Force," Clin Chem, Vol. 51, No. 10, pp. 1955-1961, 2005.   DOI   ScienceOn
11 Tamarit-Lopez, J., Morais, S., Puchades, R., and Maquieira, A., "Use of Polystyrene Spin-coated Compact Discs for Microimmunoassaying," Anal Chim Acta, Vol. 609, No. 1, pp. 120-130, 2008.   DOI   ScienceOn
12 Lee, B. S., Lee, J. N., Park, J. M., Lee, J. G., Kim, S., Cho, Y. K., and et al., "A Fully Automated Immunoassay from Whole Blood on a Disc," Lab Chip, Vol. 9, No. 11, pp. 1548-1555, 2009.   DOI   ScienceOn
13 Madou, M., Lee, J., Daunert, S., Lai, S., and Shih, C., "Design and Fabrication of CD-like Microfluidic Platforms for Diagnostics: MIcrofluidic Functions," Biomed Microdevices, Vol. 3, No. 3, pp. 245-254, 2001.   DOI   ScienceOn
14 Hoffmann, H., Riegger, L., Bundgaard, F., Mark, D., Zengerle, R., and Ducree, J., "Optical Non-contact Localization of Liquid-gas Interfaces on Disk during Rotation for Measuring Flow Rates and Viscosities," Lab Chip, Vol. 12, No. 24, pp. 5231-5236, 2012.   DOI   ScienceOn
15 Abi-Samra, K., Kim, T. H., Park, D. K., Kim, N., Kim, J., Kim, H., Cho, Y. K., and Madou, M., "Electrochemical Velocimetry on Centrifugal Microfluidic Platforms," Vol. 13, No. 16, pp. 3253-3260, 2013.   DOI
16 Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., and et al., "Passive Mixing in a Three-dimensional Serpentine Microchannel," J. Microelectromech S, Vol. 9, No. 2, pp. 190-197, 2000.   DOI   ScienceOn
17 Kim, D. S., Lee, S. H., Kwon, T. H., and Ahn, C. H., "A Serpentine Laminating Micromixer Combining Splitting/Recombination and Advection," Lab Chip, Vol. 5, No. 7, pp. 739-747, 2005.   DOI   ScienceOn
18 La, M., Park, S., Kim, H., Park, J., Ahn, K., Ryew, S., and et al., "A Centrifugal Force-based Serpentine Micromixer (CSM) on a Plastic Lab-on-a-disk for Biochemical Assays," Microfluid Nanofluid, Vol. 15, No. 1, pp. 87-98, 2013.   DOI   ScienceOn
19 Ryu, S. P., Park, J. Y., and Han, S. Y., "Optimum Design of an Active Micro-mixer using Successive Kriging Method," Int. J. Precis. Eng. Manuf., Vol. 12, No. 5, pp. 849-855, 2011.   과학기술학회마을   DOI   ScienceOn