• 제목/요약/키워드: Acoustic Measurement

검색결과 896건 처리시간 0.028초

철도환경소음을 줄이기 위한 소음감소기의 설치제안 (Installation Effect on Noise Reducer for Railway Traffic Noise)

  • 김정태;홍윤혁
    • 한국철도학회논문집
    • /
    • 제10권3호
    • /
    • pp.278-283
    • /
    • 2007
  • Community noise, especially a rail traffic noise has been serious social issues in Korea. Our society needs practical tools to reduce noise levels for public who live near the railway lines. This paper proposes a noise reducer for railway traffic noise. At the beginning, various types of reducers are discussed, with the advantages and disadvantages with respect to acoustical phenomena. Then, the acoustic effects are discussed based on an insertion loss measurement. After several types of reduces are installed at fields, the noise level is monitored with and without the reducer. The result shows that the proper selection of reducers affects the noise level by 6 dB. The statistics of the mean and a standard deviation turns out to be 3.2 dB and 0.8 dB, respectively. Noise reducers are strongly recommended for the place where apartments are densely constructed alone the railway. Installation of noise reducers seems to be an effective and practical solution for the community traffic noise reduction.

A Novel Integration Scheme for Audio Visual Speech Recognition

  • Pham, Than Trung;Kim, Jin-Young;Na, Seung-You
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.832-842
    • /
    • 2009
  • Automatic speech recognition (ASR) has been successfully applied to many real human computer interaction (HCI) applications; however, its performance tends to be significantly decreased under noisy environments. The invention of audio visual speech recognition (AVSR) using an acoustic signal and lip motion has recently attracted more attention due to its noise-robustness characteristic. In this paper, we describe our novel integration scheme for AVSR based on a late integration approach. Firstly, we introduce the robust reliability measurement for audio and visual modalities using model based information and signal based information. The model based sources measure the confusability of vocabulary while the signal is used to estimate the noise level. Secondly, the output probabilities of audio and visual speech recognizers are normalized respectively before applying the final integration step using normalized output space and estimated weights. We evaluate the performance of our proposed method via Korean isolated word recognition system. The experimental results demonstrate the effectiveness and feasibility of our proposed system compared to the conventional systems.

Non-destructive assessment of carbonation in concrete using the ultrasonic test: Influenced parameters

  • Javad Royaei;Fatemeh Nouban;Kabir Sadeghi
    • Structural Engineering and Mechanics
    • /
    • 제89권3호
    • /
    • pp.301-308
    • /
    • 2024
  • Concrete carbonation is a continuous and slow process from the outside to the inside, in which its penetration slows down with the increased depth of carbonation. In this paper, the results of the evaluation of the measurement of concrete carbonation depth using a non-destructive ultrasonic testing method are presented. According to the results, the relative nonlinear parameter caused more sensitivity in carbonation changes compared to Rayleigh's fuzzy velocity. Thus, the acoustic nonlinear parameter is expected to be applied as a quantitative index to recognize carbonation effects. In this research, combo diagrams were developed based on the results of ultrasonic testing and the experiment to determine carbonation depth using a phenolphthalein solution, which could be considered as instructions in the projects involving non-destructive ultrasonic test methods. The minimum and maximum accuracy of this method were 89% and 97%, respectively, which is a reasonable range for operational projects. From the analysis performed, some useful expressions are found by applying the regression analysis for the nonlinearity index and the carbonation penetration depth values as a guideline.

풍동실험결과를 이용한 프로펠러 무인 항공기의 환경인증소음 예측에 관한 연구 (Effective Perceived Noise Level Prediction for a Propeller driven UAV by using Wind Tunnel Test Data)

  • 이재하;이욱;최종수
    • 한국항공우주학회지
    • /
    • 제41권1호
    • /
    • pp.10-16
    • /
    • 2013
  • 본 논문에서는 풍동 실험을 통해 취득한 소음측정 결과에서 실제 비행에 기체에서 발생되는 소음을 예측하는 과정에 대하여 다루었으며 정지된 소음원을 비행하는 것과 같은 상태로 시뮬레이션 할 수 있는 방법에 대하여 소개하고 실험을 통하여 검증하였다. 또한 국제민간항공기구(이하 ICAO)에서 규정한 절차에 따라 틸트로터 항공기 및 무인항공기의 환경소음을 평가할 수 있는 방안을 제시하였다. 제시한 평가 방안을 검증하기 위해서 풍동실험과 비행시험에 대한 소음실험 시뮬레이션 프로그램을 구성하였으며 7kg급 무인항공기를 통한 풍동 실험 및 비행 실험을 수행하였으며 풍동 실험 결과로부터 비행 상태의 소음예측이 가능하다는 것을 확인 할 수 있었다.

Fused Silica와 Al2024-T4의 비선형 파라미터 측정 (Measurement of Ultrasonic Nonlinearity Parameter of Fused Silica and Al2024-T4)

  • 강토;이택규;송성진;김학준
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.14-19
    • /
    • 2013
  • 금속 재료의 비선형 파라미터는 고유한 물성치로서 기본주파수의 음압의 크기($A_1$)과 2차고조파의 음압의 크기($A_2$)을 측정하면 산정할 수 있다. 하지만, 실험적으로 $A_1$$A_2$를 측정하는 것은 매우 복잡한 변환 과정이 필요하기 때문에 현재 많은 연구자들이 비선형 파라미터의 절대값을 측정하지 않고, 전압 변화를 관찰하는 비선형 파라미터의 상대값을 측정하고 있다. 하지만, 비선형 파라미터 상대값으로는 재료의 물성치를 대변할 수가 없기 때문에, 열화도에 따른 시편 측정에만 사용할 수 있는 제약이 있다. 따라서 본 연구에서는 정전용량 측정기법(capacitive detector)보다는 비용이 적게 소모되고 현장 적용이 가능한 압전형 수신기법(piezoelectric detection)을 이용하여 비선형 파라미터의 절대값을 측정하기 위한 시스템을 구축하였다. $A_1^2vsA_2$ 그래프로 시스템의 선형성을 검증하고 시험편인 fused silica와 Al2024-T4에 대한 비선형 파라미터를 측정하였다.

동물 이명 검사용 GPIAS 측정 장치 구현과 이를 통한 자극 배경음의 시작 시점이 놀람 반응에 주는 영향 (An Implementation of a GPIAS Measurement System for Animal Tinnitus Detection and Study on Effect of Starting Point of Stimulus Background Sound on Startle Response)

  • 전보람;정재윤;이승하;박일용
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.410-414
    • /
    • 2013
  • As one of the effective methods for researching the objective tinnitus detection, the GPIAS (Gap Pre-pulse Inhibition of Acoustic Startle) measurement has been used to verify the existence of animal tinnitus objectively. The level and pattern of the background sound presented prior to a startle pulse are closely related with the GPIAS results. But the effect of the starting point of the background sound on animal startle responses has not been reported yet. In this paper, we present the implementation of a GPIAS measurement system based on an unconstrained enclosure to avoid animals' excessive constraint stress and deal with the animals' growth. After the performance of our implemented system has been tested through the animal experiment using 4 SD-rats, the effect of starting point of stimulus background sound on the startle response has been studied by the use of our implemented system. Through the results, it is verified that our system can measure the inhibition of animal startle responses due the gap pre-pulse for GPIAS calculation and the background sound starting point does not significantly effect on the startle response and the GPIAS values if the background sound continues for more than 300msec before a gap pre-pulse is presented.

휴대용 수중청음기 배열 시스템의 개발 (Development of a Portable Hydrophone Array System)

  • 김봉채
    • 한국음향학회지
    • /
    • 제25권4호
    • /
    • pp.178-183
    • /
    • 2006
  • 수중음장의 공간적인 분포를 측정하거나 해양에서 음파의 도래방향을 탐지하기 위하여 수중청음기 배열을 사용하고 있다. 그런데 수중청음기 배열은 일반적으로 규모가 크고 가격도 고가이다. 그래서 수중청음기 배열을 다루기가 편리하지 못하고, 구입하기도 쉽지 않다. 수중청음기 배열을 간편하게 구성하여 수중음파를 수신하는 데 사용할 목적으로 수중청음기와 데이터 로거가 일체형인 수중청음기 로거를 개발하였다. 그리고 수중청음기 로거로 구성된 수중청음기 배열 시스템을 개발하였다. 이 논문에서는 개발된 수중청음기 로거 및 수중청음기 배열 시스템의 구성에 대하여 보고한다. 또한 수중청음기 로거의 수조실험 결과 및 수중청음기 배열 시스템에 의한 해수중 주위잡음의 측정 예에 대하여 고찰한다. 그리고 이 수중청음기 배열 시스템을 사용할 때 편리한 점에 대해 기술한다.

혈관협착팬텀의 제작 및 파워도플러의 영상 평가 (Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler)

  • 박희영;배종림;김정구
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.732-739
    • /
    • 2009
  • 혈관협착의 혈류 정보와 초음파 진단장비의 품질보증을 위한 혈관협착 팬텀을 자동 주입기를 이용하여 제작하였다. 혈관협착의 진단에 효율성이 높은 파워 도플러를 이용하여 제작된 혈관 협착 팬텀의 유용성을 조사하고, 초음파 영상 파라메타에 따른 혈관협착의 정도를 확인하였다. 혈관 협착 팬텀은 직경이 각각 8mm와 2.4mm인 실리콘 튜브로 혈관협착이 70%가 되도록 제작하였으며, 인체 조직과 유사한 음향 특성을 가지고 있는 젤라틴을 이용하여 실리콘 튜브를 감싸 주었다. 평면형 탐촉자를 이용하여 측정하였을 때 정상 혈관의 직경은 대체적으로 감소되어 측정 되었으며, 협착 혈관의 직경은 증가되어 측정되었다. 이득이 60% 이상, PRF가 3000Hz 이상, 필터가 max와 같은 급격한 변화를 제외하고는 각각의 파라메타에 크게 영향을 받지 않았으며, 각도에는 영향을 받지 않는 것으로 나타났다. 또한 곡면형 탐촉자를 이용할 경우 이득, PRF, 필터, 각도등에 영향을 받는 것으로 나타났다. 본 연구에서 제작된 자동주입기를 이용한 혈관 협착 팬텀은 혈관 협착 진단의 품질보증에 유용하게 이용될 수 있을 것으로 기대된다.

전산유체역학과 ADV기술을 이용한 장폭비의 DAF조내 수리흐름에 미치는 영향 연구 (Examining the Effect of L/W Ratio on the Hydro-dynamic Behavior in DAF System Using CFD & ADV Technique)

  • 박노석;권순범;이선주;배철호;김정현;안효원
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.421-428
    • /
    • 2005
  • Dissolved air flotation (OAF) is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In this study, we investigated the effect of L/W (L; Length, W; Width) on the hydro-dynamic behavior in DAF system using CFD (Computational Fluid Dynamics) and ADV (Acoustic Doppler Velocimetry) technique. The factual full-scale DAF system, L/W ratio of 1:1, was selected and various L/W ratio (2:1, 3:1, 4:1 and 5:1) conditions were simulated with CFD. For modelling, 2-phase (gas-liquid) flow equations for the conservation of mass, momentum and turbulence quantities were solved using an Eulerian-Eulerian approach based on the assumption that very small particle is applied in the DAF system. Also, for verification of CFD simulation results, we measured the factual velocity at some points in the full-scale DAF system with ADV technique. Both the simulation and the measurement results were in good accordance with each other. As the results of this study, we concluded that L/W ratio and outlet geometry play important role for flow pattern and fine bubble distribution in the flotation zone. In the ratio of 1:1, the dead zone is less than those in other cases. On the other hands, in the ration of 3:1, the fine bubbles were more evenly distributed.

원통형 음향 홀로그라피를 이용한 성덕대왕 신종의 방사음장 특성 분석 (An analysis of the Sound Radiation Characteristics of the King Song-Dok Bell Using Cylindrical Acoustic Holography)

  • 김양한;김시문
    • 한국음향학회지
    • /
    • 제16권4호
    • /
    • pp.94-100
    • /
    • 1997
  • 성덕대왕 신종의 방사 음장 특성을 분석하기 위하여 30개의 마이크로폰으로 구성된 어레이를 이용하여 360개의 위치에서 음압을 측정한 후 원통형 음향 홀로그라피 방법을 적용하여 시간, 주파수별로 음장 해석을 행하였다. 타종 직후, 신종에서 방사되는 음장은 넓은 주파수 영역(800Hz까지 해석)에 걸쳐 고른 분포를 가지나 시간이 지남에 따라 고주파 성분은 급격히 감쇠하여 약 10초 이후에는 저주파 성분만이 존재한다. 마찬가지로 시간에 따른 음압 신호를 살펴보면 초기에 여러 성분의 모우드들이 중첩되어 복잡한 모양을 하고 있으나 10초 이후에는 한쌍의 저주파 성분(64.06Hz, 64.38Hz)에 의한 맥놀이 현상이 나타남을 확인할 수 있다. 이 맥놀이에 의한 여음이 초기의 화려하면서 장엄한 소리와 어우러져 신종만의 독특한 소리를 나타낸다. 맥놀이 현상은 종의 축에 대한 비대칭 현상에 의해 근접한 고유진동수를 가지기 때문에 발생하며 다른 고주파 성분에서도 쌍으로 존재하는 고유진동수를 관찰할 수 있다. 저주파 모우드의 경우 쌍으로 존재하는 방사 음장 형태는 길이 방향 절선 간격의 반에 해당되는 각도만큼 회전되어 나타난 것을 제외하고는 동일함을 알 수 있으며 고주파 모우드의 경우는 이보다 복잡한 모양을 이루고 있다.

  • PDF