• 제목/요약/키워드: Accumulated capacity

검색결과 164건 처리시간 0.025초

Project Performance Evaluation and Workload Monitoring Technique by Using Input/Output Bipolar Diagram

  • Lee, Jung-Gyu;Jeong, Seung-Ryul
    • 인터넷정보학회논문지
    • /
    • 제18권4호
    • /
    • pp.79-87
    • /
    • 2017
  • Company A, an embedded system manufacturer, provides its products to Company P which is the parent company of Company A. Both companies learned that they needed to find over 4,000 bugs before market release in order to meet the acceptable quality level. Traditionally, they had utilized time-series line graphs as their common performance measurement tool. These graphs compared accumulated numbers of bugs fixed with accumulated numbers of bugs found. Engineers in Company A had been under pressure to improve the process capacity because the line for bugs fixed was always below than the line for bugs found. By using a newly designed Bipolar diagram, engineers in Company A analyzed the process performance. And they were in a position to be more flexible for internal or inter-companies meeting. Authors explain an empirical study of a graphical and practical performance measurement tools relating to mainly the Bipolar diagram. As a result, the Bipolar diagram provides workload monitoring and performance measurement functions in a given timeframe by using the concepts of Optimum Process Line (or band) and Fair Process Capacity Zone.

Development of seismic collapse capacity spectra for structures with deteriorating properties

  • Shu, Zhan;Li, Shuang;Gao, Mengmeng;Yuan, Zhenwei
    • Earthquakes and Structures
    • /
    • 제12권3호
    • /
    • pp.297-307
    • /
    • 2017
  • Evaluation on the sidesway seismic collapse capacity of the widely used low- and medium-height structures is meaningful. These structures with such type of collapse are recognized that behave as inelastic deteriorating single-degree-of-freedom (SDOF) systems. To incorporate the deteriorating effects, the hysteretic loop of the nonlinear SDOF structural model is represented by a tri-linear force-displacement relationship. The concept of collapse capacity spectra are adopted, where the incremental dynamic analysis is performed to check the collapse point and a normalized ground motion intensity measure corresponding to the collapse point is used to define the collapse capacity. With a large amount of earthquake ground motions, a systematic parameter study, i.e., the influences of various ground motion parameters (site condition, magnitude, distance to rupture, and near-fault effect) as well as various structural parameters (damping, ductility, degrading stiffness, pinching behavior, accumulated damage, unloading stiffness, and P-delta effect) on the structural collapse capacity has been performed. The analytical formulas for the collapse capacity spectra considering above influences have been presented so as to quickly predict the structural collapse capacities.

저궤도 위성의 외란 토크 해석 (Analysis of External Disturbance Torque on a LEO Satellite)

  • 임조령;김용복;용기력
    • 항공우주기술
    • /
    • 제10권1호
    • /
    • pp.193-200
    • /
    • 2011
  • 본 연구는 저궤도의 태양동기궤도 위성에 미치는 외란 토크의 크기와 영향을 해석하였다. 위성체 좌표계에서 보았을 때, 지구 지향 자세에서 최대 토크는 약 $8.3{\times}10^{-4}$ Nm로 한 궤도당 약 1.4 Nms 의 모멘텀이 축적되고, 태양지향 자세에서의 최대 토크는 약 $1.6{\times}10^{-3}$ Nm로 한 궤도당 약 3.0 Nms 의 모멘텀이 축적된다. 한 궤도당 축적되는 모멘텀의 양은 토커의 크기를 결정하는 설계 기준 자료로 사용되는데, 현재 사용 가능한 자기 토커의 한 궤도당 모멘텀 덤핑 용량을 고려했을 때, 위성의 임무 수행을 위해 적절한 선택임을 확인하였다.

시험방법에 의한 대용량 유입변압기의 열화진단 (Ageing Diagnostics in Oil Transformer for Large Capacity due to Test methods)

  • 심윤태;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.96-99
    • /
    • 2003
  • In this paper, ageing diagnostics in the large capacity oil transformer are investigated. Following items are investigated for the ageing diagnostic in transformer oils (leakage current of sensor, power consumption and temperature of transformer oil). All temperature data are gathered from daily report in the substation. The power consumption of transformer are gathered output report of APIS(Airport Power Information System). Especially, data of sensor leakage current are accumulated from the online diagnostic system for transformer oil. The temperature of transformer oils major change factor was ambient temperature and capacity of power load. The leakage current are change by oil temperature. The leakage current ware not more than 2 [nA] in summer,

  • PDF

측정 출력곡선과 기상자료를 이용한 소형 풍력발전기 연간 발전량 비교평가 (Measured AEP Evaluations of a Small Wind Turbine using Measured Power Curve & Wind Data)

  • 김석우
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.32-38
    • /
    • 2013
  • In an efforts to encourage renewable energy deployment, the government has initiated so called 1 million green homes program but the accumulated installation capacity of small wind turbine has been about 70kW. It can be explained in several ways such that current subsidy program does not meet public expectations, economic feasibility of wind energy is in doubt or acoustic emission is significant etc. The author investigated annual energy production of Skystream 3.7 wind turbine using measured power curve and wind resource data. The measured power curve of the small wind turbine was obtained through power performance tests at Wol-Ryoung test site. AEP(Annual Energy Production) and CF(Capacity Factor) were evaluated at selected locations with the measured power curve.

Bioaccumulation Patterns and Ecophysiological Responses of Monochoria korsakowi Exposed to Cadmium

  • Lim, Yang-Hoan;Kim, In-Sung;Shim, Hyo-Jung;Kang, Kyung-Hong;Lee, Eun-Ju
    • Animal cells and systems
    • /
    • 제10권3호
    • /
    • pp.125-130
    • /
    • 2006
  • We have examined the bioaccumulation patterns and the ecophysiological responses (photosynthetic pigment and total antioxidative capacity) of Monochoria korsakowi exposed to various cadmium concentrations, one of major environmental pollutants. Cadmium ion contents in M. korsakowi increased significantly with higher cadmium concentration, and most of the accumulated cadmium was found in the root parts. Biomass of each part decreased with higher cadmium concentration. As cadmium treatment concentration was increased, chlorophyll a content was decreased, whereas chlorophyll b content was increased. However, the variations of total chlorophyll and carotenoid contents were not evident. Total antioxidative capacity in the leaves of cadmium treated M. korsakowi increased greatly with higher cadmium concentration. We considered these results as indicative of the ability of M. Korsakowi plants to take up cadmium from wetlands.

코아형식에 따른 원통형 배수재의 구멍막힘에 의한 배수능력 평가비교 (Evaluation on Drainage Capacity of Cylindrical Drain with Different Core Shapes)

  • 이광열;데이비드;윤성태;지호열
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.311-315
    • /
    • 2006
  • Various core shapes of cylindrical drains are used for accelerating primary consolidation for soft clay deposits, but serious harmful disadvantages on drainage capacity may occur on cylindrical drains due to confining Pressure when they are installed in that soil. In this study, two different core shapes of cylindrical drain are used to evaluate the drainage capacity with consideration of clogging effects on their filter jackets for an applied confining pressure. Column tests with radial drainage system were conducted under confining pressure of 50 kPa for 13 days. Two parameters which are discharge and accumulated volume of water drained were measured as the time elapsing. From this experimental study, the results showed that at the Initial stage before the clogging developed enough, the cylindrical drain with angular-type-plastic-core could produce discharge twice higher (maximum) than those with round-type. After 13 days had passed on, cylindrical drain with angular-type-plastic-core could produce discharge only 20% higher than those with round-type one. Eventually, there is a possibility that the efficiency of using angular-type-cylindrical-drain will be similar to the round-type one as the clogging develops more.

  • PDF

Removal of Heavy Metals by Cladophora sp. in Batch Culture: The Effect of Wet-mixed Solidified Soil (loess) on Bioremoval Capacities

  • Kim, Jin-Hee;Lee, Kyung-Lak;Kim, Sook-Chan;Kim, Han-Soon
    • 생태와환경
    • /
    • 제40권4호
    • /
    • pp.537-545
    • /
    • 2007
  • The heavy metal removal capacity of filamentous green alga Cladophora sp. cultured together with wet-mixed solidified soil (loess) was tested. A Cladophora sp. was cultured for 5d, with added Chu No. 10 medium, in stream water contaminated by high concentration of heavy metals from a closed mine effluent. Heavy metal ion concentrations of the medium and in algal tissue were measured every day during the experiment. Dissolved metals (Al, Cd, Cu, Fe, Mn, Zn) in medium were rapidly removed (over 90% elimination) within 1-2d when alga and loess were added. Dissolved heavy metals dropped by only 10% when algae were cultured without loess. The Cladophora sp. accumulated much more heavy metals when cultured with loess than when the alga was cultured alone. Cladophora sp. exhibited a maximum uptake capacity for Al ($17,000{\mu}g^{-1}$ algal dry weight). The metal bioremoval capacities of the algae were in the order Al, Fe, Cu, Mn, Zn and Cd. The heavy metal removal capacity of Cladophora sp. showed significant increases when wet-mixed solidified soil was added to culture media.

H형 복공판과 Channel형 복공판의 정적해석 및 피로거동에 관한 실험적 연구 (An Experimental Study on the Static and Fatigue Behavior of H & Channel-Type Lining Board)

  • 김두환;이승수;박대열;이태수
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2003년도 춘계 학술논문발표회 논문집
    • /
    • pp.508-513
    • /
    • 2003
  • The objective of this paper is to investigate the lining board's capacity by using the static loading test and fatigue test. Specimens that constitute the H & Channel type lining board are adopted. The test is to inspect the possibility of retrofit and efficiency, which is required to upgrade the structure's capacity and to examine the effects of the improvements of specimen by using structural analysis, stress analysis, static loading test and fatigue test, respectively. The accumulated test results of stress condition and deflection by bending will be used to analyze the relation between the cause of fatigue crack occurrence and the behavior of both structure system and the steel.

  • PDF

전력설비용 가교 Polyethlene의 Glass 전이점에서의 전기전도 특성에 관한 연구 (A Study on Electric Conduction Characteristic in the Glass Transition Point of electric Power Equipments Cross - Linked Polyethylene)

  • 김강원;서장수;김병인;국상훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.64-68
    • /
    • 1991
  • It happened that there was a sudden peak with the capacity of change, when I measured the capacity of change, cubical expansion and Thermally Stimulated Current on the Cross - Linked Polythylene. Crystal melting began at 375 K and changed into formaless shapeless at 380 K. The conduct of a particle on the surfase of dipole, electron trap was founded to be ion conduction nature under the low electronic field, wherase, the electron nature under the high electronic field. Consequentity, under the semi-conduction layer electronic a particle was injected to inter-fase and accumulated for a time and appeared to be TSC.

  • PDF