• Title/Summary/Keyword: Accelerated stability test

Search Result 99, Processing Time 0.028 seconds

A Basic Study on Accelerated Life Test Method and Device of DSA (Dimensionally Stable Anode) Electrode (촉매성 산화물 전극 (DSA, Dimensionally Stable Anode)의 가속수명 테스트 방법과 장치에 관한 기초 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.467-475
    • /
    • 2018
  • The lifetime of the electrode is one of the most important factors on the stability of the electrode. Since the lifetime of the DSA (Dimensionally stable anode) electrode is long, an accelerated lifetime test is required to reduce the test time. Beacuse there is no basis or standard method for accelerated lifetime testing, many researchers use different methods. Therefore, there is a need for basis and methods for accelerated lifetime testing that other researchers can follow. We designed a reactor system for accelerated lifetime testing and planned specific methods. Reactor system was circulating batch reactor. Reactor volume and cooling water tank were 12.5 L and 100 L, respectively. Electrode size was $2cm{\times}3cm$ (real electrolysis area, $5cm^2$). In order to maintain the harsh conditions, accelerated lifetime test was carried out in a high current density ($0.6A/cm^2$) and low electrolyte concentration (NaCl, 0.068 mol/L). Maintaining a constant temperature was an important operation parameter for exact accelerated lifetime test. As the accelerated lifetime test progressed, the active component of electrode surface was consumed and desorption occurred. At the point of 5 V rise, corrosion of the surface of the base material(titanium) also started.

COLOR STABILITY OF CURRENT PROSTHETIC COMPOSITES UNDER ACCELERATED AGING AND IMMERSION IN A COFFEE SOLUTION

  • Kim, Hyo-Jin;Heo, Seong-Joo;Koak, Jai-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.225-235
    • /
    • 2002
  • The color stability of current prosthetic composites is unknown, even though the quality of composite materials has been improving. This study examined the intrinsic color stability of various current prosthetic resins (ceramic-polymers) after an accelerated aging process and the extrinsic color stability after immersion in a coffee solution. By comparing the amount of discoloration after aging with that without aging, the effect of the accelerated aging process on external discoloration could be evaluated. Three current prosthetic composites (Artglass, Targis, Sculpture), one light polymerized direct composite (Z100) and one dental porcelain control (Ceramco) were assessed. The color changes (${\Delta}$E) of all the specimens were determined using the CIE $L^{*}a^{*}b^{*}$ color order system with a reflected spectrophotometer. The results were as follows: 1. The prosthetic composite materials subjected to the accelerated aging test showed no significant difference in color changes (p >.05). 2. In the coffee solution immersion test after the aging process, the color changes of the Targis and Artglass groups were not different from that of the Z100 group, which showed the highest color change. 3. In the immersion only test, a significantly high color change was observed in the sculpture glazing group. 4. The aging process influenced on the color changes more in the Targis, Artglass and Z100 groups than in the Sculpture and Ceramco groups.

A Study on Suitable Condition of Accelerated Aging Test and Evaluation Criteria of Data Stability for Archival Performance Analysis of BD-R media (BD-R 장기보존 특성 평가를 위한 가속 열화 실험 조건과 안정성 평가 기준에 관한 연구)

  • Lee, Kwan-Yong;Park, Sun-Joo;Kim, Do-Hyun;Jo, Yi-Hyung;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • The Blu-ray Disc Recordable(BD-R) is one of strong candidates for archival application among optical media formats, because of its large capability. However, the well-defined accelerated aging test conditions and evaluation criteria have not yet been fully confirmed for BD-R. In this study, the data stability and degradation aspect of BD-R were analyzed by the random-symbol error rate(R-SER) measurement after the accelerated aging test. And a reasonable test condition of accelerated aging for BD-R and the appropriate evaluation criterion using R-SER measurement were discussed.

THE COLOR STABILITY OF DIRECT DENTURE RELINE RESINS (의치상 직접 이장레진의 색조 안정성)

  • Kang Eun-Sook;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Statement of problem : Direct denture reline resins tend to discolor during service in the oral environment by intrinsic and extrinsic factor. Purpose : This study was designed to evaluate the color stability of direct denture reline resins. Material and methods : Mild Rebaron(GC Corp., Japan), Meta Base M(Sun medical Co., Japan), Mild Rebaron LC(GC Corp., Japan) and as a control group, Vertex SC(Dentimex Zeist, Holland) were chosen for this study. Ten specimens of each direct denture reline resins were fabricated. Treatment methods designed for this study were the coffee staining test(7days) and the accelerated aging test(100hours). The color changes before and after treatment were measured by Tristimulous colorimeter(Yasuda seiki seisakusho, Ltd. Japan) and analyzed. Results All the direct denture reline resins subjected to the coffee staining test and the accelerated aging test showed noticible difference in color change. After coffee staining test, Meta Base M showed the highest color change followed by Vertex SC. Mild Rebaron LC and Mild Rebaron. There were no statistical differences between Meta Base M and Vertex SC and between Mild Rebaron LC and Mild Rebaron(p>0.05). After accelerated aging test. Mild Rebaron LC showed the highest color change followed by Vertex SC, Meta Base M and Mild Rebaron. There were no statistical differences only between Mild Rebaron and Mata Base M(p>0.05) but among the others, there were statistical differences(p<0.05). Conclusion : Within the limitation of this study, all the direct denture reline resins subjected to the extrinsic and intrinsic factors showed noticible difference in color change, and there were differences among manufacturers.

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

A Study to Evaluate Performance of Poly-Urethane Polymer Concrete for Long-Span Orthotropic Steel Bridge (장경간 강바닥판 케이블교량에 적용하기 위한 폴리우레탄 폴리머콘크리트의 공용특성 연구)

  • Park, Heeyoung;Lee, Junghun;Kwak, Byeongseok;Choi, Iehyun;Kim, Taewoo
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • PURPOSES: The purpose of this study is to evaluate physical properties, durability, fatigue resistance, and long-term performance of poly-urethane concrete (PU) which can be possible application of thin layer on long-span orthotropic steel bridge and to check structural stability of bridge structure. METHODS : Various tests of physical properties, such as flexural strength, tensile strength, bond strength and coefficient of thermal expansion tests were conducted for physical property evaluation using two types of poly urethane concrete which have different curing time. Freezing and thawing test, accelerated weathering test and chloride ion penetration test were performed to evaluate the effect of exposed to marine environment. Beam fatigue test and small scale accelerated pavement test were performed to assess the resistance of PU against fatigue damage and long-term performance. Structural analysis were conducted to figure out structural stability of bridge structure and thin bridge deck pavement system. RESULTS: The property tests results showed that similar results were observed overall however the flexural strength of PUa was higher than those of PUb. It was also found that PU materials showed durability at marine environment. Beam fatigue test results showed that the resistances of the PUa against fatigue damage were two times higher than those of the PUb. It was found form small scale accelerated pavement test to evaluate long-term performance that there is no distress observed after 800,000 load applications. Structural analysis to figure out structural stability of bridge structure and thin bridge deck pavement system indicated that bridge structures were needed to increase thickness of steel deck plate or to improve longitudinal rib shape. CONCLUSIONS: It has been known that the use of PU can be positively considered to thin layer on long-span orthotropic steel bridge in terms of properties considered marine environment, resistance of fatigue damage and long-term performance.

Mechanical Properties of Zelkova Serrata Makino in Accelerated Weathering Test (촉진 열화 느티나무 부재의 역학적 특성)

  • Kim, Gwang-Chul;Park, Chun-Young
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.4
    • /
    • pp.392-397
    • /
    • 2015
  • This study was carried out to analyze the effects on mechanical properties of deteriorated wood member by outdoor condition. The surface color, mechanical properties and structural stability of traditional wooden structures, exposed in water and UV, could be changeable. For the purpose, accelerated weathering test based on outdoor condition was carried out. The weathering time levels were composed 0, 500, 1000, 1,500 and 2,000 hours and mechanical properties were evaluated on each specimen according to weathering time level. Bending properties were decreased on weathering but recovered after 1,000 hours. Fatigue and impact strength were decreased to 1,000 hours and did not changed since then. Abrasion resistance was minimized in 1,000 hours. This results could be utilized for effectively stability management of traditional wooden structures and members.

Evaluation of Physical Properties and Long-term Stability of Expansion Materials for Emergency Repair by Temperature (긴급복구용 팽창재료의 온도에 따른 물리적 특성 및 장기 안전성 평가)

  • Park, Jeongjun;Kim, Kisung;Kang, Hyounhoi;Kim, Ju-Ho;Hong, Gigwon
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.1
    • /
    • pp.79-88
    • /
    • 2018
  • In this study, the changes of the expansion and strength according to the temperature of the emergency repairing expansion material were examined by cup foaming test and uniaxial compressive strength test, and the accelerated compression creep test was carried out to confirm the long term stability. Ramp & Hold test and accelerated compressive creep test were performed to evaluate the creep performance. The short - term creep test was used to determine the initial creep strain of the expanding material. The isothermal method using time - To evaluate the long - term compressive creep performance.

Effect of coarse aggregates and sand contents on workability and static stability of self-compacting concrete

  • Mohamed, Sahraoui;Taye, Bouziani
    • Advances in concrete construction
    • /
    • v.7 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • In this paper, the workability and static stability were evaluated using a proposed test method. Workability and static stability represent a key property of self-compacting concrete (SCC) in fresh state. A number of standardized test methods were developed to assess these properties. However, no accelerated test method reliably predicts both workability and static stability of SCC. In the present work, a modified K-slump test method was developed to evaluate workability and static stability of SCC. In order to take implicit mixture variations of SCC constituents that can affect fresh SCC properties, a central composite design was adopted to highlight the effect of gravel to sand ratio (G/S), gravel 3/8 to gravel 8/15 ratio (G1/G2), water to cement ratio (W/C), marble powder to cement ratio (MP/C) and superplasticizer content (SP) on workability measured with slump and flow time (T50) tests and static stability measured with sieve stability test (Pi), segregation test index (SSI), Penetration test (Pd) and the proposed K-slump test (Km). The obtained results show that G/S ratio close to 1 and G1/G2 ratio close to 60% can be considered as optimal values to achieve a good workability while ensuring a sufficient static stability of SCC. Acceptable relationships were obtained between Slump flow, Pi, Pd and Km. Results show that the proposed K-slump test allow to assess both workability and static stability of fresh SCC mixtures.

Dissolution and Stability Enhancements of Trimethoprim by ${\beta}-Cyclodextrin$ Polymer Inclusion Complexation (트리메토프림과 ${\beta}$-시클로덱스트린 고분자 간의 포접복합체 형성에 의한 용출 및 안정성 향상)

  • Kim, Hyung-Tae;Park, Kyung-Ock;Seo, Seong-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.2
    • /
    • pp.105-113
    • /
    • 1992
  • To improve the solubility and dissolution rate of trimethoprim (TMP), which is slightly soluble drug, its inclusion complexes were prepared and studied in this experiment. Inclusion complexes of TMP with ${\beta}-cyclodextrin$ and ${\beta}-cyclodextrin$ polymer (CDPS) were prepared according to Fenyvesi method. These were compared with TMP and its physical mixture with CDPS. Water, diluted hydrochloric acid and phosphate buffer solution were used as dissolution media. And accelerated stability test was studied at $50,\;70\;and \;80^{\circ}C$. It was found that solubility and dissolution rate of inclusion complexes were increased in water. Especially, the solubility and dissolution rate of TMP was found to be markedly increased by inclusion complexation with CDPS. In stability test, ${\beta}-cyclodextrin$ inclusion complexes were more or less stable than TMP alone. This tendency was not led in CDPS. Consequently, CDPS was useful in increasing dissolution rate and stability of TMP.

  • PDF