• 제목/요약/키워드: Accelerated On/Off Test

검색결과 15건 처리시간 0.035초

제품 신뢰성 확보을 위한 배전 계통에 사용되는 전자개폐기 가속스트레스시험에 관한 연구 (To Ensure A Product Reliability The Study on Accelerated Stress Tests for Magnetic Switch Used in Power Distribution System)

  • 류행수;박상용;한규환;권영일;윤남식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.377-380
    • /
    • 2005
  • In this paper, accelerated stress test(AST) for Magnetic Switch (MS) are applied to assure specified reliability of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, AST for product assembly are developed in order to improve the weak point so that increase the product reliability. Also we will show the basic information for the accelerated life test(ALT). The proposed AST results and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in the world markets.

  • PDF

수소발생용 Ni-Zn-Fe 합금 전극의 간헐적 작동에 따른 비활성화 특성 (Intermittent Operation Induced Deactivation Mechanism for HER of Ni-Zn-Fe Electrode for Alkaline Electrolysis)

  • 한지민;김종원;배기광;박주식;정성욱;정광진;강경수;김영호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.8-22
    • /
    • 2020
  • In this study, we investigated the deactivation characteristics of Ni-Zn-Fe electrodes due to intermittent operation in alkaline water electrolysis. To find suitable method to accelerate deactivation of electrode, the accelerated stress-test (AST) which repeated on/off step was performed with constant current/voltage control. The AST under constant voltage control is suitable to deactivate electrode so it were selected to investigate deactivation of electrode. The AST which repeated on/off step in range of -1.3 V and 0 V was performed and the relationship between oxidation current and electrode deactivation in the off step was investigate. As results, it was confirmed that the nickel and zinc on electrode surface were oxidized due to anodic current which occurred at off step.

아크튜브내의 구성물 손실이 세라믹 메탈 핼라이드 램프의 특성에 미치는 영향분석 (Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube)

  • 장혁진;양종경;박대희
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2446-2452
    • /
    • 2009
  • A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.

급속 촉진 탄산화 시험을 통한 플라이애쉬 콘크리트의 탄산화 특성 연구 (A Study on the Carbonation Characteristics of Fly Ash Concrete by Accelerated Carbonation Test)

  • 최성;이광명;정상화;김주형
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.449-455
    • /
    • 2009
  • 최근 각종 산업화에 따른 탄산가스 배출량의 증가는 철근콘크리트구조물의 탄산화를 촉진시켜 구조물의 내 구성을 저하시키고 있다. 이미 선진 각국에서는 탄산가스 증가량을 고려하여 철근콘크리트구조물의 탄산화에 관한 안 전 관리 대책을 마련하고 있지만 현재까지도 실 구조물의 탄산화를 정확하게 예측하기 어렵고 탄산화 측정하기 위해서 는 많은 시간과 노력이 소요된다. 최근에 개발된 급속 촉진 탄산화 시험은 대기 중 $CO_2$농도를 100%로 하여 보다 신속 하게 탄산화 시험 결과를 제공할 수 있다. 본 논문에서는 플라이애쉬 콘크리트의 탄산화 특성을 알아보기 위하여 기존 에 주로 사용된 촉진 탄산화 시험과 급속 촉진 탄산화 시험에 의한 탄산화 결과를 비교, 분석하였다. 또한 장기재령에 서 플라이애쉬 콘크리트의 탄산화 특성을 알아보기 위하여 급속 촉진 탄산화 시험을 이용하여 재령 180일의 콘크리트 시편의 탄산화 실험을 수행하였다. 그 결과 플라이애쉬 콘크리트는 초기재령에서 탄산화에 다소 취약하였지만, 장기재 령에서는 OPC에 비하여 탄산화 저항성이 향상됨을 알 수 있었다.

GGBFS 콘크리트에 매립된 Notch를 가진 FRP Hybrid Bar의 부식저항성 평가 (Evaluation of Anti-Corrosion Performance of FRP Hybrid Bar with Notch in GGBFS Concrete)

  • 오경석;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.51-58
    • /
    • 2016
  • 콘크리트 구조물은 내구성과 경제성이 확보된 건설재료이지만, 매립된 철근의 부식은 내구적인 문제뿐 아니라 구조물의 안전성에 큰 영향을 준다. 본 연구는 유리섬유와 강재를 에폭시로 일체화 시킨 FRP Hybrid Bar를 적용한 콘크리트에 대해 염해 침투 저항성과 부식수준에 따른 부착성능을 평가하였다. 이를 위해 일반 강재를 적용한 OPC(Ordinary Portland Cement)시편과 GGBFS를 30% 혼입한 시편에 대하여 부식을 0~10% 촉진하여 부착력을 평가하였다. 또한 FRP Hybrid Bar는 에폭시 코팅으로 인해 보통 상태에서는 부식 진전이 매우 작으므로 notch를 인위적으로 가하여 OPC 콘크리트에 매립시켰으며, 이후 부식실험을 수행하였다. 실험 결과, 부식된 철근의 부착력이 21% 수준으로 감소해도 FRP Hybrid Bar에 발생된 notch는 부착력에 큰 영향이 없는 것으로 평가되었다. 또한 GGBFS 콘크리트를 사용한 부재의 경우, 통과 전류가 감소하여 일반철근을 사용해도 70%이상의 부착력을 유지하고 있었다.

배전선로에 사용되는 전자개폐기(Magnetic Switch)의 가속수명시험에 관한 연구 (A Study on Accelerated Life Tests for Magnetic Switch Used in Distribution System)

  • 유행수;한규환;권영일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.536-540
    • /
    • 2002
  • In this paper, accelerated life test (ALT) models and procedures for Magnetic Switch (MS) are developed and applied to assure specified reliability of the products at development phase and guarantee the life of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, ALT models for MS are developed using the relationship between stresses and life characteristics of products. Using the ALT models, we performed life tests and analyzed the tests results. The proposed ALT models and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in world markets.

  • PDF

Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • 장혁진;양종경;이종찬;김우영;신익태;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.219-219
    • /
    • 2009
  • ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.

  • PDF

DSC, ARC, ISCO를 활용한 다양한 순도를 가진 AP의 장기 열적안정성 연구 (Study on the Long-term Thermal Stability by DSC & ARC and its ISCO behaviors with different AP Quality)

  • 김승희;권국태;이소정
    • 한국추진공학회지
    • /
    • 제22권2호
    • /
    • pp.59-65
    • /
    • 2018
  • AP(Ammonium Perchlorate, $NH_4ClO_4$)를 포함하는 복합화약조성의 등온가열시험시, 일정 순도 이하의 AP를 사용하는 경우 "bulged"현상으로 인해 등온가열시험 결과를 얻을 수 없었다. 본 연구는 품질 혹은 순도에 따른 AP의 열적 안정성 차이에 대해 규명하기 위해 LOT 별 AP에 대해 DSC 결과를 분석하고, 그 분석결과를 등온가열시험 결과 및 ARC결과와 비교분석하였다. 또한 순도가 낮은 AP에 대해서는 재결정을 통해 포함된 불순물을 제거한 후 분석한 결과, 열적 안정성이 높아졌음을 확인하였다. DSC 고압팬을 사용하여 AP 순도를 결정하는 정량적 분석방법을 확립하였다.

철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가 (Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests)

  • 신재호;이동훈;이재봉;신성호
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

고속 광통신 시스템용 비대칭 분포귀환형 레이져 다이오드의 신뢰성에 관한 연구 (Reliablity of Distributed Feedback Laser Diodes for High-speed Optical Communication Systems)

  • 전수창;주한성;윤일구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.96-99
    • /
    • 2005
  • As the demand of internet networks using backbone communication systems recently increased, the researches on the high-speed wideband optical communication systems are required. For high-speed optical communication systems, asymmetric sampled grating distributed feedback laser diodes (DFB-LDs) are developed and the reliability of DFB-LDs is examined. The reliability of DFB-LDs is performed by monitoring I-V and L-I characteristics and two degradation phenomena related to the electrical characteristics of LDs are observed during the life tests. The first degradation phenomenon by increasing the reverse current is considered as a formation of leakage current path enough to prevent lasing operation in lateral blocking layer near active region of lasers. The second degradation phenomenon by decreasing the forward current is considered as activation of non-radiative Auger recombination process by thermal energy and the second degradation phenomenon is recovered after the off-test period at room temperature Eventually, evaluating the reliability of DFB LDs can allow us to improved the manufacturability in high-volume manufacturing.

  • PDF