Browse > Article

Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube  

Jang, Hyeok-Jin (원광대 정보통신공학과)
Yang, Jong-Kyung (원광대 전자재료공학과)
Park, Dae-Hee (원광대학교)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.58, no.12, 2009 , pp. 2446-2452 More about this Journal
Abstract
A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.
Keywords
Ceramic Metal Halide Lamp; Accelerated On/Off Test; Arc Tube; Wall Blackening; Tungsten;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 광원기술연구회 'HID광원의 기술 동향,' 대한전기학회지: 전기의 세계, v.56, no.8, pp.24-30, 2007년 8월   과학기술학회마을
2 G C Wei, 'Transparent ceramic for lighting', Journal of the European Ceramic 7051; No. of pp.8, 2008   DOI   ScienceOn
3 장혁진, 김남군, 양종경, 이종찬, 박대희 '음향 공명 현상을 고려한 세라믹 메탈핼라이드의 특성 분석과 PSpice 시뮬레이션을 통한 인버터 설계', 대한전기학회논문지, v.58,no.10,pp.1989-1994, 2009   과학기술학회마을
4 고재준, '형광램프용 전자식안정기 신뢰성 향상에 관한 연구', 한양대학교 공학대학원 석사학위논문, 2006
5 J J Curry, Craig J Sansonetti and J Wang, profiles and thermal losses m 150W high-intensity discharge lamps,' J, Phys. D: Appl. Phys. 38, 3086-3092, 2008   DOI   ScienceOn
6 Wei Yan, S.Y.R. Hui, 'Ageing Effects on the Stability Performance of Small Wattage Metal-Halide(MH)Lamps', Proc. Appl. Power Electron. Conf. Expo (APEC), vol. 2, Feb. 22 - 26, p. 978, 2004   DOI
7 W van Erk, 'Transport processes in metal halide gas discharge lamps', Pure and applied chemistry, vol. 72, No. 11, pp.2159-2166, 2000   DOI   ScienceOn
8 이영주, 박태근, 정희석, 김정수, 김진선, 김도형, '고압방전램프의 신뢰도 모형과 분석', 한국전기공사협회 전기설비 4월호, 2006
9 산업자원부 기술표준원 발행, ‘신뢰성 평가기준 고압방전램프 RS C 0085', 2월 16일, 2007
10 W. Yan , S. Y. R. Hui and Y. K. E. Ho, 'Stability study and control methods for small-wattage high-intensity-discharge (HID) lamps', IEEE Trans. Ind. Appl., vol. 37, pp. 1522, Sep./Oct. 2001   DOI   ScienceOn
11 Yuji SHATA, Tashiro KASUYA, Yasuyuki KIMURA, Shigeo GOTOH, Motoi WADA, 'Study on the Wall Blackening of a High Intensity Discharge Lamp', J. Plasma Fusion Res. Vol. 8, 2009
12 Walter P Lapatovich, 'Metal-halide lamp design:atomic and molecular data needed', IOPscience Physica Scripta, Issue T134, 014024(6pp), 2009   DOI   ScienceOn
13 이주호, 양종경, 김남군, 장혁진, 박대희 '세라믹 메탈핼라이드 램프 아크튜브 구조에 따른 광학적 특성', 대한전기학회논문지, v.57,no.12, pp.2244-2248, 2008   과학기술학회마을
14 EC Guest, MH Girach, SA Mucklejohn and U Rast, 'Effects of dimming 150W ceramic metal halide lamps on efficacy, reliability and lifetime', Lighting Res. Technol. 40: 333-346, 2008   DOI