Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.

4MV X-선을 이용한 조직보상체 두께비 연구 및 응용 (A study on tissue compensator thickness ratio and an application for 4MV X-rays)

  • 김영범;정희영;권영호;김유현
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.55-61
    • /
    • 1996
  • A radiation beam incident on irregular or sloping surface produces an inhomogeneity of absorbed dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator should be made based on experimentally measured thickness ratio. The thickness ratio depends on beam energy, distance from the tissue compensator to the surface of patient, field size, treatment depth, tissue deficit and other factors. In this study, the thickness ratio was measured for various field size of $5cm{\times}5cm,\;10cm{\times}10cm,\;15cm{\times}15cm,\;20cm{\times}20cm$ for 4MV X-ray beams. The distance to the compensator from the X-ray target was fixed, 49cm, and measurement depth was 3, 5, 7, 9 cm. For each measurement depth, the tissue deficit was changed from 0 to(measurement depth-1)cm by 1cm increment. As a result, thickness ratio was decreased according to field size and tissue deficit was increased. Use of a representative thickness ratio for tissue compensator, there was $10\%$ difference of absorbed dose but use of a experimentally measured thickness ratio for tissue compensator, there was $2\%$ difference of absorbed dose. Therefore, it can be concluded that the tissue compensator made by experimentally measured thickness ratio can produce good distribution with acceptable inhomogeneity and such tissue compensator can be effectively applied to clinical radiotherapy.

  • PDF

유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구 (A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter)

  • 노성진;김효진;김현;정동혁;손태건;김정기;양광모;남상희;강영록
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.202-210
    • /
    • 2015
  • 저선량 조사는 낮은 선량을 지속적으로 장기간 조사시키기 때문에 조사되는 마우스들에 대한 선량분포를 정확히 알고 있어야만 한다. 본 연구는 저선량 방사선에 대한 생물학적 영향평가를 위하여 동남권원자력의학원 연구센터에 설치된 $^{137}Cs$ 조사장치에 대하여 마우스조사 실험 시 마우스에 원하고자 하는 선량을 전달하기 위한 방법에 대하여 연구를 수행하였다. 마우스에 원하고자 하는 정확한 선량을 전달하기 위하여 선원에 대하여 동일한 위치에 마우스 케이지 45개를 설치할 수 있는 아파트를 자체 개발하였으며, 개발된 마우스 아파트 시스템에 대한 선량평가를 하기 위하여 유리선량계(glass dosimeter)를 실험용 마우스 머리와 배에 삽입한 후 기존 조사 시스템과 자체 개발한 마우스 아파트 시스템에 대해 비교 선량평가를 수행하였다. 기존시스템의 조사방식에서 최대 42%의 선량차이를 보였으며 개발한 마우스 아파트 시스템은 6% 이내의 선량차이를 보였다. 본 연구를 통해 개발된 마우스 아파트를 활용한 저선량 방사선에 대한 생물학적 영향평가 연구는 전달하고자 하는 선량을 보다 정확하게 제공할 수 있으며, 생물학적 분석결과에 신뢰성을 확보할 수 있다.

Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산 (Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.155-162
    • /
    • 1998
  • 방사성 동위원소의 치료에 베타 방출 선원이 많이 이용되고 있다. 베타 방출 핵종 들은 투과력이 약해 방사선 도달거리 (range)가 짧아 병소내에 직접 주입하여 선택적으로 병소만을 조사하여 치료 의 효과를 얻을 수 있고 주변 정상 조직의 방사선 피폭을 줄일 수 있다. 최근 한국 원자력연구소의 원자로인 하나로를 이용하여 베타 입자 방출체인 Ho-l66 용액을 만들어 여기에 키토산 화합물을 표지 하였다. Ho-l66 은 고 에너지 베타 방출체라는 점과 일부 감마선이 방출됨으로써 감마카메라로 쉽게 영상을 얻을 수 있다는 장점이 있다. 본 연구에서는 감마카메라로 얻은 평면 영상을 이용하여 Ho-l66으로 치료한 부위와 그 주변의 정상 장기들의 방사선 홉수선량을 구하였다. 감마카메라는 Siemens 의 2중 head를 가진 Multispect2 시스템이 이용되었고, 콜리메이터는 medium energy, 최대 에너지는 80 keV, 창은 20%로 5분간 영상을 획득하였다. Ho-166 에 대한 투과인자 (transmission factor)는 환자 있을 때와 없을 때의 영상으로 관심영역의 ROIs 의 비로 구하였다 .3일간의 평면 영상으로 유효반감기를 구하여 Marinelli 공식과 MIRD 공식으로 베타입자에 대한 방사선 흡수선량을 구하였다. 감마선에 의한 흡수선량은 매우 적으므로 무시하였다. Transmission factor는 환자에 따라 다르지만 1110 MBq(30 mCi)을 주입하여 치료에 임한 간암 환자의 경우 간은 4.6, 비장은 4.65, 폐는 3.34, 뼈는 5.65 의 값을 보였다. 방사선 홉수선량은 tumor 에는 179.7, 정상간에는 16.3, 비장은 18.5, 폐에는 7.0, 뼈에는 9.0 Gy 가 각각 계산되었다. 이를 tumor dose 에 100%로 normalization 시킬 경우 정상간, 비장, 폐, 뼈에 각각 9.1, 10.3, 3.9, 5.0%로 분포되었음을 알았다. 본 연구를 통하여 tumor dose 뿐만이 아니고 주변 주요 위험장기 (critical organ) 에 대한 방사선 흡수선량을 전ㆍ후면 평면영상으로 얻을 수 있음을 보여 줌으로써 평면영상법을 이용한 dosimetry 의 가능성을 보았다. 또한 주변 주요 위험 장기의 한계선량에 맞는 주입할 양을 결정하는데 기초 자료가 될 수 있음을 보여준다.

  • PDF

Properties of Water Substitute Solid Phantoms for Electron Dosimetry

  • Saitoh, Hidetoshi;Tomaru, Teizo;Fujisaki, Tatsuya;Abe, Shinji;Myojoyama, Atsushi;Fukuda, Kenichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.255-259
    • /
    • 2002
  • To reduce the uncertainty in the calibration of radiation beams, absorbed dose to water for high energy electrons is recommended as the standards and reference absorbed dose by AAPM Report no.51 and IAEA Technical Reports no.398. In these recommendations, water is, defined as the reference medium, however, the water substitute solid phantoms are discouraged. Nevertheless, when accurate chamber positioning in water is not possible, or when no waterproof chamber is available, their use is permitted at beam qualities R$\_$50/ < 4 g/cm$^2$ (E$\_$0/ < 10 MeV). For the electron dosimetry using solid phantom, a depth-scaling factor is used for the conversion of depth in solid phantoms to depth in water, and a fluence-scaling factor is used for the conversion of ionization chamber reading in plastic phantom to reading in water. In this work, the properties, especially depth-scaling factors c$\_$p1/ and fluence-scaling factors h$\_$pl/ of several commercially available water substitute solid phantoms were determined, and the electron dosimetry using these scaling method was evaluated. As a result, it is obviously that dose-distribution in solid phantom can be converted to appropriate dose-distribution in water by means of IAEA depth-scaling.

  • PDF

전립샘암의 방사선 치료 시 입체조형치료법와 세기조절방사선 치료법의 비교 (A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Radiation Therapy on Prostate Cancer)

  • 김영재;이재섭;홍성일;고혜진
    • 한국방사선학회논문지
    • /
    • 제7권6호
    • /
    • pp.409-414
    • /
    • 2013
  • 본 연구에서는 전립샘암 환자에게 방사선 치료법인 3차원 입체조형법과 세기조절치료법을 각각 적용 할 경우 선량분포의 차이를 관찰하여 치료기법의 우수성을 평가하고자 하였다. 실험대상자 10명의 컴퓨터 단층 모의치료영상을 얻어 종양학과 전문의가 종양용적 및 정상장기를 구분하고 종양용적에 흡수선량을 80 Gy로 설정한 후 각각 다른 치료계획을 수립하였다. 그 결과 선량분포윤곽은 세기조절치료법이 우수 하였고 종양조직의 흡수선량은 세기조절치료법이 처방선량에 근접(100.2%)하였으며 정상조직 흡수율(방광, 직장, 소장, 좌 우 대퇴골두) 또한 우수하였다. 즉, 전립샘암의 방사선 치료시 세기조절방사선치료가 입체조형치료법보다 선량적인 면에서 양호한 것으로 분석되었다.

전립선암의 방사선치료에서 토모테라피와 VMAT의 치료계획에 따른 유용성 평가 (Usefulness Evaluation on the Treatment Plan of Tomotherapy and VMAT in Radiotherapy for Prostate Cancer)

  • 허광명;한재복;최남길
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.449-457
    • /
    • 2015
  • 전립선암의 방사선치료에서 토모테라피와 용적변조회전치료(volumetric modulated arc therapy, VMAT)의 치료계획에 따른 유용성 평가를 위해 흡수선량, 선량체적곡선(dose volume histogram, DVH), 치료효율성, MapCHECK2를 이용한 선량 검증 정확도 결과를 각각 비교 분석하였다. 대상으로는 2014년 7월부터 12월까지 H 대학병원 방사선종양학과에서 토모테라피 치료를 받은 전립선암 환자 중 12명을 무작위로 선택하였다. 흡수선량과 DVH를 분석한 결과 종양조직과 방광에서 두 방사선 치료계획이 근소한 차이를 나타냈지만 처방선량의 오차범위인 -5%에서+3%안에 포함됐고 정상조직 부작용 확률 권고치인 견딤선량 범위를 넘지 않았다. 치료시간은 2.5배 짧고 MU(monitor unit)도 10.3배 작아 VMAT가 치료효율성이 높았다. 선량정확도는 모두 95% 이상의 통과기준에 포함 되었으며 VMAT가 2.3% 더 높게 나타났다. 토모테라피와 VMAT 모두 종양조직에 적합한 선량이 흡수되었으며 정상조직의 견딤선량 범위를 넘지 않아 선량분포특성에서 큰 차이는 없었다. 하지만 치료시간이 짧고, total MU가 낮아 치료효율성이 좋고 선량 검증의 정확도 또한 우수한 VMAT를 선택하는 것이 치료에 더 유용할 것으로 사료된다.

속중성자선의 선량분포에 관한 연구 (Fast Neutron Beam Dosimetry)

  • 지영훈;이동한;류성렬;권수일;신동오;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.45-57
    • /
    • 1997
  • 속중성자선을 임상에 이용하기 위해서는 속중성자선의 선량 및 선량분포를 정확히 측정하는 것이 매우 중요하다. 현재 속중성자선의 측정법은 크게 나누어 American Associations of Physicists in Medicine, European Clinical Neutron Dosimetry Group 및 International Commission on Radiation Units and Measurements에 의하여 제시되고 있으나 측정의 복잡함으로 인하여 서로 약간씩 다른 방법을 제시하고 있다. 따라서 본 연구에서는 중성자 치료장치에서 방출되는 속중성자선의 방출선량 및 물질 내 선량분포 등의 측정을 통하여 독자적인 측정기술을 확보하고, 우리 실정에 알맞은 표준측정법을 개발하고자 하였다. 속중성자선의 선량 및 물질 내 선량 분포 측정에는 조직등가물질인 A-150 플라스틱으로 제작된 IC-17 및 IC-18 이온함, 마그네슘으로 제작된 IC-17M 이온함, TE 기체, Ar 기체 및 RDM 2A electrometer 등을 사용하였다. 연구 결과 중성자선에 혼합되어 있는 ${\gamma}$선의 오염도는 기준조사면 깊이 5cm에서 약 13% 로 나타났으며, 깊이가 깊어질수록 증가하였다. 기준 조사면에 대하여 중심축선상의 최대 선량 깊이는 1.32cm 이었으며, 50% 선량 깊이는 14.8cm로 나타났다. 표면선량율은 전 조사면에 걸쳐서 41.6%~54.1%이었으며 조사면가 커질수록 증가하였다. Beam profile 은 2.5cm 깊이에서 7.5% 정도 horne effect가 나타났으며 10cm 깊이에서 가장 평탄하였다.

  • PDF

반무한(半無限) 방사성운(放射性雲)에서의 흡수선량계산(吸收線量計算) - 1. 단일(單一)에너지 감마 방출체(放出體)에 대한 산난광자(散亂光子)스펙트럼의 계산(計算) - (Calculation of Absorbed Dose for Immersion in Semi-Infinite Radioactive Cloud...(1))

  • 이수용
    • Journal of Radiation Protection and Research
    • /
    • 제10권2호
    • /
    • pp.155-159
    • /
    • 1985
  • 무한균질공기(無限均質空氣)에 방사성물질(放射性物質)이 균일(均一)하게 분포(分布)된 방사성운(放射性雲)에서 피폭선량(被曝線量)은 일반적(一般的)으로 단일(單一)에너지 점등방선원(點等方線源)커넬 방법(方法)에 의하여 계산(計算)하고 있다. 이 방법(方法)의 가장 큰 제한성(制限性)은 인체표면(人體表面)에서만의 선량(線量)을 개산(槪算)한다는 사실(事實)이다. 이와같은제한성(制限性)을 제거(除去)하기 위하여, 이 보고서(報告書)는 감마선방출대형방사성운(線放出大型放射性雲) 속에서 방사선량계산(放射線量計算)에 인체표면(人體表面)에 입사(入射)되는 산난광자(散亂光子)스펙트럼을 고려(考慮)한 다른 접근방법(接近方法)을 도입(導入)하였으며, 그 결과(結果)는 다른 연구자(硏究者)들의 결과(結果)와 잘 일치(一致)하였다. 여기에서 얻은 결과(結果)는 현재(現在) 연구(硏究)가 진행중(進行中)인 무한(無限) 또는 반무한균질공기방사선운(半無限均質空氣放射線雲)에서 MIRD팬텀내 흡수선량분포결정(吸收線量分布決定)의 입력자료(入力資料로서 이용(利用)될 것이다.

  • PDF

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF