• Title/Summary/Keyword: Absorbed dose

Search Result 571, Processing Time 0.02 seconds

Destruction of $NF_3$ Emitted from Semiconductor Process by Electron Beam Technology (전자빔 기술을 이용한 반도체 공정의 삼불화질소($NF_3$) 분해)

  • Ryu, Jae-Yong;Choi, Chang-Yong;Kim, Jong-Bum;Lee, Sang-Jun;Kim, Seung-Gon;Kwak, Hee-Sung;Yun, Young-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.391-396
    • /
    • 2012
  • The destruction study of $NF_3$ gas emitted from the semiconductor industry is performed with electron-beam technology. Absorbed dose (kGy) and current ranged from 0 (0) to 400 kGy (20 mA). The concentration of $NF_3$ gas ranged from 500 to 2,000 ppm. In order to assess the effect of a residence time on DRE (Destruction and Removal Efficiency, %), experiments also conducted at different irridiation times of 5 sec, 10 sec, 15 sec and 20 sec respectively. As absorbed dose and current increased, DRE of $NF_3$ was also increased. However, DRE (%) of $NF_3$ decreased with increasing the concentration of $NF_3$ gas. The DRE of $NF_3$ was about 90% at an absorbed dose of 400 kGy.

Image-Based Assessment and Clinical Significance of Absorbed Radiation Dose to Tumor in Repeated High-Dose $^{131}I$ Anti-CD20 Monoclonal Antibody (Rituximab) Radioimmunotherapy for Non-Hodgkin's Lymphoma (반복적인 $^{131}I$ rituximab 방사면역치료를 시행 받은 비호지킨 림프종 환자 군에서 종양 부위의 영상기반 방사선 흡수선량 평가와 임상적 의의)

  • Byun, Byung-Hyun;Kim, Kyeong-Min;Woo, Sang-Keun;Choi, Tae-Hyun;Kang, Hye-Jin;Oh, Dong-Hyun;Kim, Byeong-Il;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.60-71
    • /
    • 2009
  • Purpose: We assessed the absorbed dose to the tumor ($Dose_{tumor}$) by using pretreatment FDG-PET and whole-body (WB) planar images in repeated radioimmunotherapy (RIT) with $^{131}I$ rituximab for NHL. Materials and Methods: Patients with NHL (n=4) were administered a therapeutic dose of $^{131}I$ rituximab. Serial WB planar images alter RIT were acquired and overlaid to the coronal maximum intensity projection (MIP) PET image before RIT. On registered MIP PET and WB planar images, 2D-ROls were drawn on the region of tumor (n=7) and left medial thigh as background, and $Dose_{tumor}$ was calculated. The correlation between $Dose_{tumor}$ and the CT-based tumor volume change alter RIT was analyzed. The differences of $Dose_{tumor}$ and the tumor volume change according to the number of RIT were also assessed. Results: The values of absorbed dose were $397.7{\pm}646.2cGy$ ($53.0{\sim}2853.0cGy$). The values of CT-based tumor volume were $11.3{\pm}9.1\;cc$ ($2.9{\sim}34.2cc$), and the % changes of tumor volume before and alter RIT were $-29.8{\pm}44.3%$ ($-100.0%{\sim}+42.5%$), respectively. $Dose_{tumor}$ and the tumor volume change did not show the linear relationship (p>0.05). $Dose_{tumor}$ and the tumor volume change did not correlate with the number of repeated administration (p>0.05). Conclusion: We could determine the position and contour of viable tumor by MIP PET image. And, registration of PET and gamma camera images was possible to estimate the quantitative values of absorbed dose to tumor.

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

DNA Damage by X-ray and Low Energy Electron Beam Irradiation (X선과 저에너지 전자선에 의한 DNA 손상)

  • Park, Yeun-Soo;Noh, Hyung-Ah;Cho, Hyuck;Dumont, Ariane;Ptasinska, Sylwia;Bass, Andrew D.;Sanche, Leon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.53-59
    • /
    • 2008
  • We observed DNA damages as a function of mean absorbed dose to identify the indirect effect of high-energy radiation such as x-ray. Monolayer films of lyophilized pGEM-3Zf(-) plasmid DNA deposited on tantalum foils were exposed to Al $K{\alpha}$ X-ray (1.5 keV) for 0, 3, 7 and 10 min, respectively, in a condition of ultrahigh vacuum state. We compared DNA damages by X-ray irradiation with those by 3 eV electron irradiation. X-ray photons produced low-energy electrons (mainly below 20 eV) from the tantalum foils and DNA damage was induced chiefly by these electrons. For electron beam irradiation, DNA damage was directly caused by 3 eV electrons. Irradiated DNA was analyzed by agarose gel electrophoresis and quantified by ImagaQuant program. The quantities of remained supercoiled DNA after irradiation were linearly decreased as a function of mean absorbed dose. On the other hand, the yields of nicked circular (single strand break, SSB) and interduplex crosslinked form 1 DNA were linearly increased as a function of mean absorbed dose. From this study, it was confirmed that DNA damage was also induced by low energy electrons ($0{\sim}10\;eV$) even below threshold energies for the ionization of DNA.

Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source (Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자에너지 플루언스와 질량에너지흡수계수 유도)

  • Kim, Jong-Eon;Ahn, Il-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • The purpose of this study is to derive photon energy fluence and mass energy absorption coefficient for 1 Gy of absorbed dose of water in brachytherapy using an Ir192 source. From the radiotherapy physics written by Khan, the half-value of lead for the gamma ray beam of the Ir192 source was obtained. The linear attenuation coefficient and the mass attenuation coefficient were calculated from the obtained half-value layer of lead. By matching the calculated lead mass attenuation coefficient with the NIST mass attenuation coefficient data, the photon energy of the matching mass attenuation coefficient was determined as the effective energy. By matching the determined effective energy with the photon energy of the NIST data on the mass energy absorption coefficient of water, the mass energy absorption coefficient of water was obtained as 0.03273 cm2/g(32.73 cm2/kg). The photon energy fluence was calculated as 0.03055 J/cm2 by dividing the obtained mass energy absorption coefficient (32.73 cm2/kg) by the absorbed dose of water 1 Gy.

Effects of Current Intensity on the Reaction Efficiency and Kinetics of Gas Compound Decomposition by Electron Beam in a Continuous Flow System (연속식 흐름 가스상물질의 전자선 분해반응에서 전류 세기가 반응효율 및 kinetics에 미치는 영향)

  • Tak-Hyun Kim;Dong-Woo Kim;Sang-Hee Jo;Jieun Son;Seungho Yu;Tae-Hun Kim;Jong-Seok Park
    • Journal of Radiation Industry
    • /
    • v.18 no.3
    • /
    • pp.235-240
    • /
    • 2024
  • Electron beam technology has recently attracted attention as one of the powerful air pollution control methods. In this study, methyl mercaptan decomposition by electron beam in a continuous gas flow system was studied. To this, the effect of gas flowrate, which is one of important operating variables in the continuous gas flow electron beam process, on methyl mercaptan treatment efficiency was studied. In particular, the treatment efficiency and the reaction kinetics of methyl mercaptan decomposition were compared when calculated based on the absorbed dose and when calculated based on the current intensity of electron beam. When based on the electron beam absorbed dose, the treatment efficiency and 1st-order reaction constant increased as the gas flowrate was increased, contrary to the trends in general chemical reactions. However, when based on the current intensity, the treatment efficiency and 1st-order reaction constant increased as the gas flowrate was decreased, which can be theoretically explained. This is due to the fact that the current intensity increased as the gas flowrate was increased, resulting in improved the electron beam treatment efficiency. In conclusion, it is necessary to consider not only the absorbed dose but also the current intensity of electron beam in order to explain the results of reaction efficiencies and kinetics in the continuous flow electron beam gas treatment process.

Synthesis of Nickel Nanoparticles using Electron Beam Irradiation

  • Lee, Seung Jun;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.241-245
    • /
    • 2015
  • A study on the preparation of nickel oxide nanoparticles using electron beam irradiation is described. Nickel nanoparticles were synthesized with nickel chloride hexahydrate as a metal precursor and different sodium hydroxide concentrations using electron beam irradiation. The effects of sodium hydroxide concentration and electron beam absorbed doses were investigated. The samples were synthesized at different sodium hydroxide concentrations and with absorbed doses of 100 to 500 kGy at room temperature. Synthesized nanoparticles were characterized by X-ray diffraction (XRD) and field emission scanning electron microscopy (FE-SEM) and a vibrating sample magnetometer (VSM). The nanoparticle morphologies seemed to be non-spherical and aggregated. The 1:1 molar ratio of nickel chloride hexahydrate and sodium hydroxide showed a higher purity and saturation magnetization value of 13.0 emu/g. The electron beam absorbed dose was increased with increasing nickel nanoparticle nucleation.

Evaluation of Radiation Exposure to Residents by Naturally Residing Radionuclides in the Soil of Korea (한국토양 내 천연 방사성핵종에 의한 거주민의 방사선피폭평가)

  • Kim, Jung-Hoon;Kim, Ah-Reum;Ko, Seong-Jin;Whang, Joo-Ho
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.219-224
    • /
    • 2009
  • We investigated the amounts of radiation exposure from $^{238}U$, $^{232}Th$, and $^{40}K$ which are three major radionuclides naturally residing in soil of the Korean peninsula. The experimental results showed that the concentrations of the radionuclides were 15.77$\pm$7.27, 290.05$\pm$73.92 and 750.30$\pm$165.38 Bq/kg respectively. The absorbed dose rate based on the measured concentrations was 213.76$\pm$46.37 nGy/hr, while the spatial gamma absorbed dose rate measured in the same region was 123.90$\pm$19.18 nGy/hr. The effective dose rate was 0.26 mSv/yr, which is significantly higher than the world average effective dose rate 0.07 mSv/yr provided by the UNSCEAR.

  • PDF

A Study on the Environmental Radiation of Concrete Apartments and Neighborhood Living Facilities (콘크리트 공동주택과 근린생활 시설의 환경방사선에 관한 연구)

  • Ji, Tae-Jeong;Kwak, Byung-Joon;Min, Byung-In
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.100-104
    • /
    • 2009
  • In this study, the space gamma dose rates in the apartments structured with concrete were measured in accordance with construction year. In addition, the environmental radiation rates coming from the subway platforms and the road tunnels were analyzed in the equivalent dose by multiplying the absorbed dose with the radiation weighting factors. The space gamma dose rates measured in apartments were higher than those of outdoor which was $0.08{\sim}0.11uSv/h$ in the natural conditions. Especially, the older construction year is, the higher becomes space gamma dose rate. The average gamma dose rates in the subway platforms were measured. In the case of Busan and Daegu subway, the earlier the opening year is, the higher becomes dose rate. However, the dose rates of Seoul subway Lines were high overall, regardless of opening year. Seoul subway Line 6 showed the highest value of 0.21uSv/h. The gamma dose rate in road tunnels was higher than one of the outdoor and increased with opening year like as apartment. In dose rate comparison of the concrete structures with the outdoor, therefore, the space gamma dose rate of indoor is higher than one of the outdoor and the older structures have a higher dose rate.

Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence (OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가)

  • Lee, Ju-seong;Kang, Bo-ram;Kwon, Hyeon-Kyung;Park, Ji-Young;Kim, Ju-Hye;Choi, Young-Se;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are $0^{\circ}{\pm}80^{\circ}$ with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from $0^{\circ}$ to ${\pm}80^{\circ}$ for both OSLD and EBT3 film. When angle of $0^{\circ}$ is normalized to 1, and the dose is decreased to 60 and 66% at $80^{\circ}$ for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from $0^{\circ}$ to ${\pm}80^{\circ}$ for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.